Manuel d’utilisation Miller Electric 12VS

44 pages 1.96 mb
Télécharger

Aller à la page of 44

Summary
  • Miller Electric 12VS - page 1

    SuitCase X-TREME 12VS OM-1500-19 219 185P 2007 − 09 Processes Description MIG (GMAW) W elding Flux Cored (FCA W ) W elding Wire Feeder ™ ™ File: MIG (GMA W) V isit our website at www.MillerWelds.com ...

  • Miller Electric 12VS - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .Mille ...

  • Miller Electric 12VS - page 3

    T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc W elding Hazards 1 . . . . . . . ...

  • Miller Electric 12VS - page 4

    dec_stat_1/07 Declaration of Conformity for European Community (CE) Products . This information is provided for units with CE certification (see rating label on unit). Manufacturer : European Contact: Miller Electric Mg. Co. Mr . Danilo Fedolfi, 1635 W . Spencer St. Managing Director Appleton, WI 54914 USA ITW Welding Products Italy S.r .l. Phone: ...

  • Miller Electric 12VS - page 5

    OM-1500-19 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury . The possible hazards are shown in the adjoining symbols ...

  • Miller Electric 12VS - page 6

    OM-1500-19 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases. D If ventilation is poo ...

  • Miller Electric 12VS - page 7

    OM-1500-19 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit. ...

  • Miller Electric 12VS - page 8

    OM-1500-19 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.) Battery posts, terminals and related accessories contain lead and l ...

  • Miller Electric 12VS - page 9

    OM-1500-19 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes. 2-1. S ym bole s ut ilisés DANGER! − Indique une situation dangereuse qui si on l’évite pas peut donner la mort ou des blessures grav ...

  • Miller Electric 12VS - page 10

    OM-1500-19 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces. DES PIÈCES CH ...

  • Miller Electric 12VS - page 11

    OM-1500-19 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort. D Fermer l’alimentation du gaz protecteur en cas de non-utilisation. D V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué. LES CHAMPS MAGNETIQUES peuv- ent affecter des implants m ...

  • Miller Electric 12VS - page 12

    OM-1500-19 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage. DES ORGANES MOBILES peuvent provoquer des blessures. D S’abstenir de toucher d ...

  • Miller Electric 12VS - page 13

    OM-1500-19 Page 9 2-5. P ri nci pal es n or me s de s écu ri té Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .global.ihs.com). Recommended Safe Practices for the Preparation for W elding and Cut- ting of Containers and Piping , American ...

  • Miller Electric 12VS - page 14

    OM-1500-19 Page 10 ...

  • Miller Electric 12VS - page 15

    OM-1500-19 Page 1 1 SECTION 3 − DEFINITIONS 3-1. W arning Label Definitions 1 1.1 1.2 1.3 3 3.1 3.2 3.3 4 4.1 + 2 2.1 2.2 + + 56 + 2.3 S-178 936 W arning! Watch Out! There are possible hazards as shown by the symbols. Drive rolls can injure fingers Welding wire and drive parts are at welding voltage during operation − keep hands and metal objec ...

  • Miller Electric 12VS - page 16

    OM-1500-19 Page 12 3-2. Manufacturer ’ s Rating Label For CE Products Ref. 181 678 / 804 005-A S/N: Hz IP 23 VA X % V U 1 = A I 1 = U 2 =I 2 = 11 0 10.0 DC 1 10 425 60 3-3. WEEE Label (For Products Sold Within The EU) Do not discard product (where ap- plicable) with general waste. Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) ...

  • Miller Electric 12VS - page 17

    OM-1500-19 Page 13 3-4. Symbols And Definitions . Some symbols are found only on CE products. Output Input A Amperes V V olts X Duty Cycle Wire Feed Percent IP Degree Of Protec- tion Input Cold Jog (Inch) T o- wards W orkpiece Purge By Gas Fast Constant Current Circuit Breaker Constant V oltage Slow Trigger Hold Of f Trigger Hold On I 2 Rated W eld ...

  • Miller Electric 12VS - page 18

    OM-1500-19 Page 14 SECTION 4 − INST ALLA TION 4-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range Input W elding Circuit Rating IP Rating Max. Wire Spool Capacity Overall Dimensions W eight Open-Circuit/ Arc V oltage, 14 − 11 0 V olts DC Constant V oltage (CV) Or Constant Current (CC) D ...

  • Miller Electric 12VS - page 19

    OM-1500-19 Page 15 4-3. Equipment Connection Diagram Ref. 804 000-C ! T urn Off wire feeder and welding power source. Stop engine on welding generator . ! Use only with CC/CV DC Power Sources. 1 Constant Current (CC) or Constant V oltage (CV) W elding Power Supply 2 Weld Cable T o Feeder 3 Ground Cable T o W orkpiece W eld cable and ground cable co ...

  • Miller Electric 12VS - page 20

    OM-1500-19 Page 16 4-4. Installing And Aligning Wire Guide And Drive Rolls Ref. 804 001-B Installing Wire Guide And Drive Rolls: 1 Drive Roll Nut 2 Drive Roll Carrier Turn nut one click until lobes of nut line up with lobes of drive roll carrier . 3 Drive Roll Slide dr ive rol l onto drive roll carrier . T urn nut one click. Repeat procedure for to ...

  • Miller Electric 12VS - page 21

    OM-1500-19 Page 17 4-5. Connecting W elding Gun And V oltage Sensing Clamp Ref. 804 002-C ! T urn Off wire feeder and welding power source. Stop engine on welding generator . 1 Gun Securing Knob 2 Gun Block 3 Gun Outlet Wire Guide Loosen knob, insert gun end into block. Position outlet wire guide as close a s possible to drive rolls with- out touch ...

  • Miller Electric 12VS - page 22

    OM-1500-19 Page 18 4-7. Connecting Weld Cable ! T urn Off wire feeder and welding power source. Stop engine on welding generator . 1 User-Suppled Weld Cable Follow wire manufacturer’s recom- mendations for weld cable polarity . 2 User-Suppled Male Connector 3 User-Suppled Female Connector Push female connector over male connector , and turn 1/4 t ...

  • Miller Electric 12VS - page 23

    OM-1500-19 Page 19 4-9. Installing And Threading W elding Wire Ref. 804 005-B Installing Wire And Adjusting Hub T ension: 1 Retaining Nut 2 Hub T ension Adjustment Knob Remove retaining ring, and install spool so hub pin fits spool hole. Re- install retaining nut. Adjust tension knob so only a slight force is needed to turn spool. Threading Welding ...

  • Miller Electric 12VS - page 24

    OM-1500-19 Page 20 4-10. Display Board (PC20) DIP Switch Settings DIP Switch Factory Settings Ref. 804 006-A DIP Switch Settings: Display Hold ON Displays will hold their last value for five seconds after the trigger is re- leased. After the hold times out, the V oltage Display will show open circuit voltage. If the Wire Speed / Amps Display is set ...

  • Miller Electric 12VS - page 25

    OM-1500-19 Page 21 SECTION 5 − OPERA TION 5-1. Controls With Meters Ref. 804 006-B 1 Power Control Switch 2 Trigger Hold Switch Trigger hold allows operator to weld without holding gun trigger . T o use trigger hold function, place trigger hold switch in the ON position. Th e operator must hold the trigger for a mini- mum of 2 seconds, but no lon ...

  • Miller Electric 12VS - page 26

    OM-1500-19 Page 22 5-2. Controls Without Meters Ref. 804 006-B 1 Power Control Switch 2 Jog/Purge Switch Pressing the Jog switch allows the operator to jog wire without energi zing the contactor or gas valve. Pressing the Purge switch allows the opera- tor to purge gas lines before welding and to preset gas flow rate at the flowmeter . 3 Wire Speed ...

  • Miller Electric 12VS - page 27

    OM-1500-19 Page 23 5-3. Gun Consumables Information 200 007-B Notes ...

  • Miller Electric 12VS - page 28

    OM-1500-19 Page 24 5-4. Wire Speed Control Settings Ref. 222 307A Notes ...

  • Miller Electric 12VS - page 29

    OM-1500-19 Page 25 SECTION 6 − MAINTENANCE & TROUBLESHOOTING 6-1. Routine Maintenance . Maintain more often during severe conditions. ! Disconnect power before maintaining. 3 Months Replace Damaged Or Unreadable Labels Replace Damaged Gas Hose Repair Or Replace Cracked Cables And Cords 6 Months Clean Drive Rolls Blow Out Or V acuum Inside 6-2 ...

  • Miller Electric 12VS - page 30

    OM-1500-19 Page 26 6-3. T roubleshooting T rouble Remedy Wire does not feed; open-circuit voltage available. Check circuit breaker CB1. Reset CB1. Unit overheated. Allow unit to cool. Check sensing lead connection. Check gun trigger plug connection. Check gun trigger . See gun Owner ’ s Manual. Have Factory Authorized Service Agent check Control ...

  • Miller Electric 12VS - page 31

    OM-1500-19 Page 27 T rouble Remedy Information on display board is not accu- Have Factory Authorized Service Agent check Control board PC1. Information on display board is not accu rate. yg Check transducer HD1 and connections, and replace if necessary . Display on display board does not light. Have Factory Authorized Service Agent check Control bo ...

  • Miller Electric 12VS - page 32

    OM-1500-19 Page 28 Notes ...

  • Miller Electric 12VS - page 33

    OM-1500-19 Page 29 SECTION 7 − ELECTRICAL DIAGRAM 218 763-E Figure 7-1. Circuit Diagram For Wire Feeder ...

  • Miller Electric 12VS - page 34

    OM-1500-19 Page 30 SECTION 8 − P ARTS LIST Ref. 804 007-K 3 4 9 6 7 8 11 10 12 14 13 64 66 5 67 50 37 38 19 20 25 21 22 23 24 17 35 30 49 18 34 33 45 29 32 36 31 28 26 27 15 16 54 53 55 63 69 52 46 47 51 65 58 59 60 62 57 61 62 48 68 56 42 42 39 41 41 44 42 40 43 68 70 71 72 26 73 1 (Fig 8-2) 2 (Fig 8-3) Figure 8-1. Complete Assembly ...

  • Miller Electric 12VS - page 35

    OM-1500-19 Page 31 Figure 8-1. Complete Assembly Diagram marking Item No. Part No. Description Quantity 1 Fig 8-2 Panel Assembly Front (Without Meters) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Fig 8-3 Panel Assembly Front (With Meters) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric 12VS - page 36

    OM-1500-19 Page 32 Figure 8-1. Complete Assembly (Continued) Diagram marking Item No. Part No. Description Quantit y 49 207 679 Insert, Corner 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 GS1 226 819 V alve, 12VDC 1W ay .750 − 14 Thd 2mm Orf 100PSI 1 ...

  • Miller Electric 12VS - page 37

    OM-1500-19 Page 33 Ref. 804 007-K . Hardware is common and not available unless listed. 1 2 3 4 5 6 7 Figure 8-2. Front Panel Assembly without Meters Item No. Part No. Quantity Description Figure 8-2. Front Panel Assembly without Meters (Figure 8-1 Item 1) Dia. Mkgs . 1 171 007 Knob, Pointer 1.670 Dia X .250 Id W/Set ScrewSplstc 1 . . . . . . . . . ...

  • Miller Electric 12VS - page 38

    OM-1500-19 Page 34 Ref. 804 007-K . Hardware is common and not available unless listed. 1 2 3 4 5 7 6 Figure 8-3. Front Panel Assembly with Meters Item No. Part No. Quantity Description Figure 8-3. Front Panel Assembly with Meters (Figure 8-1 Item 2) Dia. Mkgs . 1 179 851 Knob, Pointer 1.670 Dia X .250 Id Push On W/Spring 1 . . . . . . . . . . . . ...

  • Miller Electric 12VS - page 39

    OM-1500-19 Page 35 T able 8-1. Drive Roll & Wire Guide Kits (2 Drive Roll) . Base selection of drive rolls upon the following recommended usages: 1. V-Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types). 4. V-Knurled rolls for ha ...

  • Miller Electric 12VS - page 40

    Notes Over 80,000 trained since 1930! 400 T rade Square East, T roy , Ohio 45373 1-800-332-9448 www.weldin g .or g Star t Y our Pr ofessional W eldin g Career Now! ...

  • Miller Electric 12VS - page 41

    Notes SOCKET/WRENCH SELECTION T ABLE (U.S. ST ANDARD) SOCKET/WRENCH SELECTION T ABLE (METRIC) Specifications Socket or Wrench Size Specifications Socket or Wrench Size Bolt Diameter Decimal Equivalent Bolt Nut Bolt Diameter U.S. Decimal Equivalent Bolt Nut 1/4 in .250 in 3/8 in 7/16 in 6 mm .2362 in 10 mm 10 mm 5/16 in .3125 in 1/2 in 9/16 in 8 mm ...

  • Miller Electric 12VS - page 42

    Notes 229895 MA TERIAL THICKNESS GAUGE ...

  • Miller Electric 12VS - page 43

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expe ...

  • Miller Electric 12VS - page 44

    PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool W orks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarters − US A USA Phone: 920-735-4505 Aut o-At tended USA & Canada F AX: 920-735-4134 Int ernati onal F A X: 920-735-4125 European Headqua rters − U ...

Fabricant Miller Electric Catégorie Welder

Les documents que nous recevons du fabricant de l'appareilMiller Electric 12VS peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Miller Electric
- manuels d’utilisations 12VS
- fiches produit Miller Electric
- dépliants
- ou étiquettes-énergie Miller Electric 12VS
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Miller Electric 12VS.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Miller Electric 12VS, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Miller Electric 12VS. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Miller Electric 12VS.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Miller Electric 12VS, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Miller Electric 12VS par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Miller Electric 12VS.

Le manuel d’utilisation complet Miller Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Miller Electric 12VS - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Miller Electric 12VS, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMiller Electric 12VS qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Miller Electric 12VS - qui devraient nous aider dans les premières étapes lors de l'utilisation Miller Electric 12VS
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Miller Electric 12VS
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Miller Electric 12VS dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Miller Electric 12VS?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Miller Electric 12VS, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Miller Electric 12VS il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)