Manuel d’utilisation Sanyo MDF-793C

32 pages 0.46 mb
Télécharger

Aller à la page of 32

Summary
  • Sanyo MDF-793C - page 1

    MDF-593C MDF-793C Ultra Low T emperature Freezer INSTRUCTION MANUAL MDF-593C ...

  • Sanyo MDF-793C - page 2

    1 Note: 1. No part of this manual may be reprodu ced in any form without the expressed w ritten permission of SANYO. 2. The contents of this manual are subject to change without notice. 3. Please contact SANYO if any point in this manual is unclear or if there are any inaccuracies. SANYO Electric Biomedical Co., Ltd. All rights reserved. Printed in ...

  • Sanyo MDF-793C - page 3

    2 PRECAUTIONS FOR SAFE OPERATION It is imperative that the user compli es with this manual as it contains important safety advice. Items and procedures are described so that y ou can use this unit correctly and safely. If the precautions advised are followed, this will prevent possible injury to the user and any other person. Precautions are illust ...

  • Sanyo MDF-793C - page 4

    3 PRECAUTIONS FOR SAFE OPERATION Do not use the unit outdoors. Current leakage or electric shock may result if the unit is exposed to rain water. Only qualified engineers or serv ice personnel should install the unit. The installation by unqualified personnel may cause electric shock or fire. Be sure to install the unit on a sturdy floor. If the fl ...

  • Sanyo MDF-793C - page 5

    4 PRECAUTIONS FOR SAFE OPERATION Ensure you do not inhale or consume medication or aerosols from around the unit at the time of maintenance. These may be harmful to your health. As w ith any equipment that uses CO 2 gas, there is a likelihood of oxy gen depletion in the vicinity of the equipment. It is important that you assess the w ork site to en ...

  • Sanyo MDF-793C - page 6

    5 PRECAUTIONS FOR SAFE OPERATION Select a level and sturdy floor for installation. This precaution will prevent the unit from tipping. Improper installation may result in water sp illage or injury from the unit tipping over. Connect the unit to a pow er source as indicated on the rating label attached to the unit. Use of any other voltage or freque ...

  • Sanyo MDF-793C - page 7

    6 PRECAUTIONS FOR SAFE OPERATION Do not touch the condenser directly when the filter is removed for cleaning. This may cause injury by hot surface. Alw ays disconnect the power supply plug before moving the unit. Take care not to damage the power cord. A damaged cord may c ause electric shock or fire. Be careful not to tip over the unit during move ...

  • Sanyo MDF-793C - page 8

    7 CAUTIONS FOR USAGE ■ Always use a dedicated power source. The power source of this freezer is single phase and local voltage. The power source should be the dedicated circuit with a dedicated breaker. Do not connect this freezer to the branch circui t for other electric appliances. ■ Put on dry gloves when you take out refrigerated ar ticles ...

  • Sanyo MDF-793C - page 9

    8 CAUTIONS FOR USAGE ■ The top surface of the frame sometimes becomes hot during the initial operation or when operating in a hot environment. This is due to the hot gas circui t for preventing dew, and is not an indication of a malfunction. ■ This unit is provided with the filter check lamp. If the filter check lamp is flashed, clean the conde ...

  • Sanyo MDF-793C - page 10

    9 ENVIRONMENTAL CONDITIONS This equipment is designed to be safe at least under the following conditions (based on the IEC 1010-1): 1. Indoor use; 2. Altitude up to 2000 m; 3. Ambient temperature 5 o C to 40 o C 4. Maximum relative humidity 80% for temperature up to 31 o C decreasing linearly to 50% relative humidity at 40 o C; 5. Mains supply volt ...

  • Sanyo MDF-793C - page 11

    10 FREEZER COMPONENTS MDF-593C 1 3 13 7 8 12 10 11 4 2 9 6 5 15 14 16 ...

  • Sanyo MDF-793C - page 12

    11 FREEZER COMPONENTS 1. Lock 2. Door: Hinged type. The door can be opened in any angle on the way to full open. 3. Magnetic door gasket: Seals the door and prevents leakage of cold air. 4. Inner lid: Serves as a means of reducing cold air leakage when the door is open. Remove the frost before it is accumulated too much. 5. Access port: Serves a me ...

  • Sanyo MDF-793C - page 13

    12 FREEZER COMPONENTS Control panel 1. Pow er sw itch (POWER): Power all functions except remote alarm and back-up system for AT type. 2. CO 2 Back-up sw itch (CO 2 BACK UP): MDF-593C is not equipped. MDF-793C is not equipped . 3. CO 2 Back-up test sw itch (TEST): MDF-593C is not equipped. MDF-793C is not equipped . 4. Remote alarm sw itch (REMOTE ...

  • Sanyo MDF-793C - page 14

    13 Clean the condenser filter according to page 25 “Cleaning of condenser filter”. INSTALLATION Installation site T o operate this unit properly and to obtain maximum performance, install the unit in a location with the following conditions: ■ A location not subjected to direct sunlight The direct sunlight to the freezer causes too high tempe ...

  • Sanyo MDF-793C - page 15

    14 INSTALLATION Installation 1. Remove the packaging materials and tapes Remove all transportation packaging materials and tapes. Open the doors and ventilate the unit. If the outside panels are dirty, clean them with a diluted neutral dishwashing detergent. (Undiluted detergent can damage the plastic components. For t he dilution, refer to the ins ...

  • Sanyo MDF-793C - page 16

    15 START-UP OF UNIT Follow the procedures for the initia l and consequent operations of the unit. 1. Make sure that all the switches on the control panel, such as the power switch, the remote alarm switch, the back-up s ystem switch are off. 2. Liquid CO 2 gas cylinder is set at this time. 3. Shut the door and connect the power cable to the power s ...

  • Sanyo MDF-793C - page 17

    16 OPERATING INSTRUCTIONS Temperature setting Table 1 shows the basic operation method. Perfor m key operations in the sequence indicated in the table. The example in the table is based on the assumption that the temperature is -70 o C. Note: The unit is set at the factory t hat the chamber temperature is -85C. Table 1. Basic operation sequence (E ...

  • Sanyo MDF-793C - page 18

    17 OPERATING INSTRUCTIONS Alarm temperature setting This unit is provided with the high temperature al arm. The setting of high temperature alarm is 10 o C or 15 o C higher than the setting of chamber temperature. The procedure in table 2 shows the sequence to set the high temperature alarm at 15 o C higher than the setting of chamber temperature. ...

  • Sanyo MDF-793C - page 19

    18 OPERATING INSTRUCTIONS Setting of alarm resume time The alarm buzzer is silenced by pressing BUZZER key on the control panel during alarm condition (Initial setting 100: The remote alarm is not silenced). The buzzer will be activated again after certain sus pension if the alarm condition is continued. The suspension time can be set by following ...

  • Sanyo MDF-793C - page 20

    19 OPERATING INSTRUCTIONS Alarm and safety functions This unit has the alarm and safety functions shown in table below, and also self diagnostic function. Table 4. Alarm and safety function Alarm & safety Situation Indication Buzzer Safety operation High temperature alarm When the chamber temp. is approx. 10 o C (or 15 o C) higher than the set ...

  • Sanyo MDF-793C - page 21

    20 OPERATING INSTRUCTIONS Back-up system WARNING As w ith any equipment that uses CO 2 gas, there is a likelihood of oxygen depletion in the vicinity of the equipment. It is important that you assess the work site to endure there is suitable and sufficient ventilation. If restricted ventilation is suspected, then other methods of ensuring a safe en ...

  • Sanyo MDF-793C - page 22

    21 TEMPERATURE RECORDER The figure below shows the description of a temperature recorder. Feeding of chart 1. Open the door and let down the lever of the penholder; the pen point is apart from the chart. (Fig. 1) 2. Pull the cartridge out of the mounted position. (Fig. 2) 3. Set a new chart in place on the rear bottom of the cartridge. Set the hole ...

  • Sanyo MDF-793C - page 23

    22 TEMPERATURE RECORDER Setting of back-up temperature 1. There is a red guide on the top of the temperature displayer. Adjust the guide with your finger to back-up temperature, at which temperature the auxiliary cooling system starts to operate. 2. Set at a temperature 15 o C higher than that of the freezer compartment. Penholder Install a recordi ...

  • Sanyo MDF-793C - page 24

    23 TEMPERATURE RECORDER When a 7day circular ty pe recorder is installed, a slip chart recorder can not be attached. Follow the procedure bellow to attach a 7day circular chart recorder to the freezer. NOTE: Only a specified recorder is applicable to the freezer. For the selection of an applicable recorder, please consult with a sales shop 1. Make ...

  • Sanyo MDF-793C - page 25

    24 TEMPERATURE RECORDER 8. Remove the sensor cover at the rear of the chamber wall. (Fig. 4) 9. Pass through the hole under the temperature control sensor. (Fig. 5) Tool for the hole: Screw driver (example) Hole depth: 135mm (5.3inch) Hole diameter: 13mm (0.5inch) 10. Route the recorder sensor into the chamber by sassing the hole. (Fig. 4) 11. Remo ...

  • Sanyo MDF-793C - page 26

    25 ROUTINE MAINTENANCE WARNING Alw ays disconnect the pow er supply to the unit prior to any repair or maintenance of the unit in order to prevent electr ic shock or injury. Ensure you do not inhale or consume medication or aerosols from around the unit at the time of maintenance. These may be harmful to your health. Cleaning 1. Clean the unit once ...

  • Sanyo MDF-793C - page 27

    26 TROUBLE SHOOTING If the unit malfunctions, check out the following before ca lling for service, after transferring all the contents to another freezer No refrigeration ■ The voltage is too low. (In this case, call an electrician.) ■ The breaker is free. ■ The fuse is blown. Sometimes the freezer is not cooled at all for about 5 minutes aft ...

  • Sanyo MDF-793C - page 28

    27 DISPOSAL OF UNIT WARNING If the unit is to be stored unused in an unsupervised area for an extended period ensure that children do not have access and doors cannot be closed completely . The disposal of the unit should be accomplished by appropriate personnel. Always remove doors to prevent accidents such as suffocation. ...

  • Sanyo MDF-793C - page 29

    28 RECYCLE OF NICKEL-CADMIUM BATTERY The unit contains a rechargeable battery. The battery is recyclable. At the end of it’s useful life, check with you loca l solid officials option or proper disposal. * Label indication is obliged to comply with Taiwanese battery regulation. Location of a nickel-cadmium battery This unit is provided a nickel- ...

  • Sanyo MDF-793C - page 30

    29 SPECIFICATIONS Name Ultra-Low Temperature Freezer Model MDF-593C MDF-793C External dimensions W2010 x D770 x H1070 (mm) W2570 x D770 x H1070 (mm) Internal dimensions W1280 x D500x H762 (mm) W1840 x D500x H762 (mm) Effective capacity 487 L 701 L Exterior Baked on acrylic finish on galvanized steel Interior Stainless steel Door Baked on acrylic fi ...

  • Sanyo MDF-793C - page 31

    30 CAUTION Please fill in this form before servicing. Hand over this form to the service engineer to keep for his and your safety. Safety check sheet 1. Refrigerator contents : Risk of infection: Risk of toxicity: Risk from radioactive sources: (List all potentially hazardous materials that have been stored in this unit.) Notes : 2. Contamination o ...

  • Sanyo MDF-793C - page 32

    7FB6P10140700 (22 Feb. 2005) Recycl ed paper CEM SANYO Electric Biomedical Co., Ltd. 10-15, Hongo 3-Chome Bunkyoku, T okyo 1 13-8434 Jap an Printed in Japan ...

Fabricant Sanyo Catégorie Freezer

Les documents que nous recevons du fabricant de l'appareilSanyo MDF-793C peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Sanyo
- manuels d’utilisations MDF-793C
- fiches produit Sanyo
- dépliants
- ou étiquettes-énergie Sanyo MDF-793C
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Sanyo MDF-793C.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Sanyo MDF-793C, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Sanyo MDF-793C. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Sanyo MDF-793C.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Sanyo MDF-793C, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Sanyo MDF-793C par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Sanyo MDF-793C.

Le manuel d’utilisation complet Sanyo, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Sanyo MDF-793C - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Sanyo MDF-793C, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSanyo MDF-793C qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Sanyo MDF-793C - qui devraient nous aider dans les premières étapes lors de l'utilisation Sanyo MDF-793C
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Sanyo MDF-793C
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Sanyo MDF-793C dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Sanyo MDF-793C?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Sanyo MDF-793C, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Sanyo MDF-793C il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)