    PRODUCT DATA 68- 022 3 - 2 ® U.S. Re g istered Trademark Co py ri g ht © 2001 Hone y well • All Ri g hts Reserved TZ-3 TotalZone® Zone Control Panel APPLICATION The TZ-3 T otalZone Zo ne Contro l Panel co ntrols si n g le-st a g e, mult i-sta g e, conv entional or heat p um p heat/cool e q ui p ment. It control s 2 o r 3 zone s, and is ex p an ...

  • Honeywell TZ-3 - page 2

    TZ-3 T OTALZONE® ZONE CONTROL PANEL 68-0223-2 2 SPECIFICAT IONS Electrical: 24 V ac, 60 Hz . Dimensions : See Fi g . 1. Mounting: Mount s with three screws (p rovided ) throu g h holes in ca binet back Wiri ng: 18 - g au g e wire for all e q ui p men t and s y stem connec tions Wiring Conn ections: Thermos tat: W2, L, G, Y , R, W Dam p ers: M 6 ( ...

  • Honeywell TZ-3 - page 3

    TZ-3 T OTALZONE® ZO NE CONTROL PANEL 3 68-0223-2 T able 2. Recomme nded Damp ers. T able 3. Required Acces sories (Not Suppl ied With Pa nel). Honeywell Dampe r T ype Round Rectangular Power-o p en/ p ower-closed MARD IOBD AOBD AOBD-BM CDO-51 S p rin g -o p en/ p ower-clo sed ARD ZDB ZDS Accesso ry Descripti on Bypass Rating (cfm) 40 V A transform ...

  • Honeywell TZ-3 - page 4

    TZ-3 T OTALZONE® ZONE CONTROL PANEL 68-0223-2 4 INSTALLATI ON Moun ting CAUTION Equipment Da mage Hazard . Do not mount TZ-3 inside HV AC equipm ent Mount onl y on wall o r on cold a ir return 1. Mount th e therm ostats i n each z one of t he livin g s p ace usin g the ins tallat ion instru ction s p rovided w ith each thermos tat. 2. Mount th e d ...

  • Honeywell TZ-3 - page 5

    TZ-3 T OTALZONE® ZO NE CONTROL PANEL 5 68-0223-2 Fig. 4. Heat pump the rmostat with s eparate Y1 a nd W1 ter minals and mu lti -sta ge th ermost at wi ring. If the thermosta t sele cted h as a sin g le Y termi nal, see Fi g . 5. Select a sin g le Y ther mosta t for each z one. S ee T able 1. Set DI P switch 6 or 7 ( not both ) to th e On p osition ...

  • Honeywell TZ-3 - page 6

    TZ-3 T OTALZONE® ZONE CONTROL PANEL 68-0223-2 6 Fig. 9. MARD and CDO-51 Dam per wiring. ML6161 Motor Act uator When the ML61 61 Motor Ac tuator is used, wire a s shown i n Fi g . 10. Wire the R8222 re la y to p revent the dam p er LE D from const antl y li g htin g amber . Fig. 10. M L6161 Damper Mo tor Actuator w iring. Transformer Wire the trans ...

  • Honeywell TZ-3 - page 7

    TZ-3 T OTALZONE® ZO NE CONTROL PANEL 7 68-0223-2 Multi -Sta g e: Wire th e e q ui p ment as shown in Fi g . 14 us in g the W2 termi nal for second s ta g e of h eat and th e W3 termi nal for third sta g e of heat . Wire th e Y2 for se cond s ta g e of cool in g . Fig. 14. He ating and coo ling equi pment. Heat Pump Equipment Wire the heat p um p t ...

  • Honeywell TZ-3 - page 8

    TZ-3 T OTALZONE® ZONE CONTROL PANEL 68-0223-2 8 Fig. 15. Heat pump w ith auxil iary heat wiring. . Fig. 16. T rane XL 1800 w ith T A YPLUS 103 i n restricte d mode wirin g. Water Source Heat Pumps Wire the e q ui p ment, a s a pp licabl e, to the TZ -3 as sho wn in Fi g . 17. T urn DIP switch num ber 8 to O n for fan on in heat. Remove th e two-st ...

  • Honeywell TZ-3 - page 9

    TZ-3 T OTALZONE® ZO NE CONTROL PANEL 9 68-0223-2 W aterfu rnace: Wire this s y stem to t he p anel as shown i n Fi g . 17 exce p t use tw o isola tion rela y s on com p ressor wires W1, Y1 and W 2, Y2. Fig. 17. W ater source heat pump wiring. STARTUP AND CHECKOUT After the i nstallati on is com p lete, veri f y corre ct o p erat ion as follows: 1. ...

  • Honeywell TZ-3 - page 10

    TZ-3 T OTALZONE® ZONE CONTROL PANEL 68-0223-2 10 OPERATION Sequence of Operation On a c all for hea tin g or coo lin g , the zone dam p er sta y s o p en to the c allin g zone, an d the d am p ers clos e to the z ones that are no t call in g . The T Z-3 p anel brin g s on the heatin g or coolin g and condition ed air is deliv ered to the callin g ...

  • Honeywell TZ-3 - page 11

    TZ-3 T OTALZONE® ZO NE CONTROL PANEL 1 1 68- 0223-2 . Stages Based On Number of Zones Calling The therm ostat co ntrols the first s ta g e of heat o r cool . The secon d sta g e of hea t and c ool and t he third sta g e of hea t are ener g ized b y the p ercenta g e of zo nes call in g . See T able 4. Set the DIP s witches as f ollows: See T able ...

  • Honeywell TZ-3 - page 12

    TZ-3 T OTALZONE® ZONE CONTROL PANEL 68-0223-2 12 Rebooting M icr op roces sor Certain conditi ons can h an g u p the mic ro p rocess or . T o reset it, p res s and rele ase th e Bo ot but ton. The s y stem re boots and enters th e Pur g e mo de. Discharge Air Temperature Sensor The Di schar g e Air T em p erat ure S ensor ( not incl uded ) is a su ...

  • Honeywell TZ-3 - page 13

    TZ-3 T OTALZONE® ZO NE CONTROL PANEL 13 68-0223-2 TROUBLESHOOTING T able 5. T roubleshooting. Symptom Possibl e Cause Action No LEDs are Illum inated No p ower to the board. Check fo r 24 V ac ( ±1 0 % ) across T R1 and TR2 Shorted wire . Check fu se. If hot, a s hort exis ts in the rmosta t, dam p er , or Zone-A-L one wirin g . Dam p er LE Ds on ...

  • Honeywell TZ-3 - page 14

    TZ-3 T OTALZONE® ZONE CONTROL PANEL 68-0223-2 14 T able 6. DIP Switch Set tings and Fun ctions. T able 7. LED Indicators. DIP Switch Function Off (default) On 1 Sta g in g b y number of zo nes callin g . Sta g es timer o r thermostat controlle d. Sta g es control led b y numbe r of z one s calli n g . 2 ZMS low li mit. 40°F 48°F 3 Pur g e mode t ...

  • Honeywell TZ-3 - page 15

    TZ-3 T OTALZONE® ZO NE CONTROL PANEL 15 68-0223-2 See Fi g . 20 for TZ -T otalZ one Zone Co ntrol Pa nel. Fig. 20. TZ-3 T otalZone Zone Con trol Panel. ZoneMAX™ TERMINALS SYSTEM ST ATUS LED INDICA TIORS TEST JUMPERS (NOT USED) ZONE DAMPER LED INDICA TORS Z ONE- A - L ONE™ SWITCH BOOT BUTTON EMERGENCY HEA T SWITCH RESETT ABLE FUSE TRANSFORMER T ...

  • Honeywell TZ-3 - page 16

    68-0223-2 G .H. Rev . 9-01 www .hone y well.com/ y ourhome Home and Building Control H ome and Building Control Honeywell Honeywell Lim ited-Honeywe ll Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. TZ-3 T ...

Fabricant Honeywell Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilHoneywell TZ-3 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Honeywell
- manuels d’utilisations TZ-3
- fiches produit Honeywell
- dépliants
- ou étiquettes-énergie Honeywell TZ-3
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Honeywell TZ-3.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Honeywell TZ-3, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Honeywell TZ-3. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Honeywell TZ-3.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Honeywell TZ-3, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Honeywell TZ-3 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Honeywell TZ-3.

Le manuel d’utilisation complet Honeywell, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Honeywell TZ-3 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Honeywell TZ-3, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHoneywell TZ-3 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Honeywell TZ-3 - qui devraient nous aider dans les premières étapes lors de l'utilisation Honeywell TZ-3
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Honeywell TZ-3
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Honeywell TZ-3 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Honeywell TZ-3?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Honeywell TZ-3, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Honeywell TZ-3 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)