    ✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • lmmediately call your gas supplier from a neighbor's phone. Follow the ...

  • Verona VEGCT424F - page 2

    2 Dear Customer , Thank you for having pur chased and given your pr efer ence to our pr oduct. The safety pr ecautions and r ecommendations r eported below are for your own safety and that of others. They will also pr ovide a means by which to make full use of the featur es offer ed by your appliance. Please pr eserve this booklet car efully . It m ...

  • Verona VEGCT424F - page 3

    3 IMPORT ANT PRECAUTIONS AND RECOMMENDA TIONS ✓ After having unpacked the appliance, check to ensure that it is not damaged. If you have any doubts, do not use it and consult your supplier or a professionally qualified technician. ✓ Packing elements (i.e. plastic bags, polystyrene foam, nails, packing straps, etc.) should not be left around wit ...

  • Verona VEGCT424F - page 4

    4 COOKING POINTS 1. Auxiliary burner (AUX) - 3.500 BTU/hr 2. Semirapid burner (SR) - 6.000 BTU/hr 3. T riple ring bur ner (TC) - 11.500 BTU/hr CONTROL P ANEL DESCRIPTION 4. Auxiliary burner (AUX) control knob (1) 5. Right semirapid burner (SR) control knob (2) 6. Left semirapid burner (SR) control knob (2) 7. T riple ring bur ner (TC) control knob ...

  • Verona VEGCT424F - page 5

    5 CHOICE OF BURNER (fig. 2.3) The symbols printed on the panel beside the gas knobs indicate the correspondence between the knob and the burner . The most suitable burner is to be chosen according to the diameter and volume capac- ity of the container to be warmed. It is important that the diameter of the pots or pans suitably match the heating pot ...

  • Verona VEGCT424F - page 6

    6 Do not use steam jet cleaners because the humidity could infiltrate into the appliance making it dangerous. GENERAL RECOMANDA TION ✓ Before you begin cleaning you must ensur e that the hob is switched off. It is advisable to clean when the appliance is cold. ✓ All enamelled surfaces have to be washed with soapy water or some other non- abrasi ...

  • Verona VEGCT424F - page 7

    7 CORRECT REPLACEMENT OF THE BURNERS It is very important to check that the burner flame spreader “ F ” and the cap “ C ” have been correctly positioned (see figs. 3.1 and 3.2 ). Failure to do so can cause serious problems. In appliances with electric ignition, check that the electrode “ S ” (fig. 3.1) is always clean to ensure tr ouble ...

  • Verona VEGCT424F - page 8

    8 W ARNING! THIS APPLIANCE HAS TO BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or pr operty damage. Consult a qualified installer , service agent, or the gas supplier . INST ALLA TION INSTRUCTIONS TOOLS NEEDED FOR INST ALLA TION Screwdriver Wrench T-handle wrench T ...

  • Verona VEGCT424F - page 9

    9 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code , ANSI Z223.1-Latest Edition. 2. Installation in manufactured (mobile) home: installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Sta ...

  • Verona VEGCT424F - page 10

    10 installation to the cabinet  min 22” 7/16 (570 mm) 30” (762 mm) 18” (457 mm) min 4” (102 mm) from cut-out max 13” (330 mm) 30” (762 mm) min 20” (508 mm) from cut-out max 13” (330 m m) 18” (457 mm) min 22” 7/16 (570 mm) Fig. 4.2a Fig. 4.2b 22” 53/64 (580 mm) 19” 11/16 (500 mm) 2” 9/16 (65 mm) 18” 7/8 (480 mm) 2” 9 ...

  • Verona VEGCT424F - page 11

    11  20 mm min. 40 mm max. B C A Fig. 4.3 Fig. 4.4 F ASTENING THE COOKTOP (fig. 4.3 - 4.4) ✓ Each cooker top is provided with an installation kit including brackets and screws for fastening the top to fixtur e panels from 2 to 4 cm thick. ✓ Tu rn the cooker top upside down and fasten the brackets “A” to the appropriate socket holes, witho ...

  • Verona VEGCT424F - page 12

    Gas supply line Shutoff valve “open” position To cooktop Fig. 5.1 12 All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to te action of LP/Pr opane gas. The cooktop is equipped f ...

  • Verona VEGCT424F - page 13

    13 PRESSURE REGULA TOR INST ALLA TION To cooktop UNLOCK LOCK LOCK To cooktop LOCK Arrow STEP 1 The elbow connection can be turned in the direction requir ed after the manifold female pipe fitting has been slackened by using a wrench. Then tighten the elbow-manifold female pipe fitting connection by using a wrench befor e proceeding with gas connect ...

  • Verona VEGCT424F - page 14

    14  To mains connection To cooktop Manifold test point pressure 1/8” NPT 1/2” G cylindrical (ISO 228-1) male Cooktop manifold Manifold female pipe fitting Elbow connection Connector Pressure regulator 1/2” G cylindrical (ISO 228-1) male 1/2” G cylindrical (ISO 228-1) female 1/2” G cylindrical (ISO 228-1) female 3/8” NPT (conical) mal ...

  • Verona VEGCT424F - page 15

    15 b) Any conversion requir ed must be performed by your dealer or a qualified licensed plumber or gas service company . Please pr ovide the service person with this manual before work is started on the cooktop. (Gas conversions ar e the r esponsibility of the dealer or end user .) c) This cooktop can be used with NA TURAL or LP/PROP ANE gas. It is ...

  • Verona VEGCT424F - page 16

    16 1 2 NATURAL GAS REGULATION LP/PROPANE REGULATION A SETTING THE PRESSURE REGULA TOR (fig. 5.5) 1. Unscrew the r egulator cover; 2. Unscrew the A component, r everse and screw it according to the LP/PROP ANE r egulation. CONVERSION TO LP/PROP ANE GAS Every cooktop is provided with a set of injectors for the various types of gas. Select the injecto ...

  • Verona VEGCT424F - page 17

    17 REGULA TING THE BURNER MINIMUM SETTING When switching from one type of gas to another , the minimum flow rate must also be correct: the flame should not go out even when passing suddenly fr om maximum to minimum flame. The adjustment is performed with the burner lit, as follows: –T urn the knob to the minimum position. – Remove the tap knob. ...

  • Verona VEGCT424F - page 18

    18 If codes permit and a separate ground wir e is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sur e whether the cooktop is prop- erly grounded. Do Not ground to a gas pipe. A 120-volt, 60-Hz, AC-only , 15-amper e, fused electrical supply is requir ...

  • Verona VEGCT424F - page 19

    19 Wiring diagram key A Ignition coil PA Ignition switches group M Te r m inal block CA Igniter Fig. 6.2 A NL PA M CA CA CA CA WIRING DIAGRAM  ...

  • Verona VEGCT424F - page 20

    Cod. 1103614-ß1 The manufacturer cannot be held r esponsible for possible inaccuracies due to printing or transcription errors in the present booklet. The manufacturer r eserves the right to make all modifications to its products deemed necessary for manufacture or commercial r easons at any moment and without prior notice, without jeopardising th ...

Fabricant Verona Catégorie Appliance Trim Kit

Les documents que nous recevons du fabricant de l'appareilVerona VEGCT424F peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Verona
- manuels d’utilisations VEGCT424F
- fiches produit Verona
- dépliants
- ou étiquettes-énergie Verona VEGCT424F
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Verona VEGCT424F.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Verona VEGCT424F, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Verona VEGCT424F. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Verona VEGCT424F.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Verona VEGCT424F, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Verona VEGCT424F par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Verona VEGCT424F.

Le manuel d’utilisation complet Verona, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Verona VEGCT424F - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Verona VEGCT424F, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVerona VEGCT424F qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Verona VEGCT424F - qui devraient nous aider dans les premières étapes lors de l'utilisation Verona VEGCT424F
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Verona VEGCT424F
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Verona VEGCT424F dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Verona VEGCT424F?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Verona VEGCT424F, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Verona VEGCT424F il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)