    CLA SSIC ® 300G OPERA TOR’S MANUAL For Machines with Code Numbers 10659,10912,11135 IM659-B December, 2004 Safety Depends on You Lincoln arc welding equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR ...

  • Lincoln Electric 11135 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric 11135 - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric 11135 - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric 11135 - page 5

    iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les ...

  • Lincoln Electric 11135 - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric 11135 - page 7

    vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Safety Precautions........................................................... ...

  • Lincoln Electric 11135 - page 8

    TECHNICAL SPECIFICA TIONS – CLASSIC 300G (K1754-1) CLASSIC 300G A-1 INST ALLA TION A-1 DC CURRENT RANGE Fine Adjustment in each Range 40-350 Amps DUTY CYCLE 100% 60% RATED DC OUTPUT* VOLTS @ RATED AMPS 30V @ 250A NEMA Rating 32V @ 300A (1) 115V will operate either 60 Hz. or 50/60 Hz. power tools, lights etc. * Based on a 10 min. period. Make/Mode ...

  • Lincoln Electric 11135 - page 9

    PRE-OPERA TION INST ALLA TION EXHAUST SP ARK ARRESTER Some federal, state or local laws may require that engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this welder does not qualify as a spark arrester. When required by ...

  • Lincoln Electric 11135 - page 10

    PRE-OPERA TION SER VICE READ the engine operating and maintenance instruc- tions supplied with this machine. OIL This unit is supplied from the factory with the engine crankcase filled with a high quality SAE 10W/30 oil. This oil should be acceptable for most typical ambient temperatures. Consult the engine operation manual for specific engine manu ...

  • Lincoln Electric 11135 - page 11

    BA TTER Y CHARGING The Classic 300G is equipped with a wet charged bat- tery. The charging current is automatically regulated when the battery is low (after starting the engine) to a trickle current when the battery is fully charged. When replacing, jumping or otherwise connecting the battery to the battery cables, the proper polarity must be obser ...

  • Lincoln Electric 11135 - page 12

    B-1 OPERA TION B-1 SAFETY PRECAUTIONS Operate the welder with the doors closed. Leaving the doors open changes the designed air flow and can cause overheating. GENERAL DESCRIPTION The Classic ® 300G is a heavy duty, engine driven, DC arc welding power source, capable of providing constant current output for stick welding or DC TIG welding. This we ...

  • Lincoln Electric 11135 - page 13

    • When hauling the welder between job sites, close the fuel feed valve beneath the fuel tank. • If the fuel supply is cut off or runs out while the fuel pump is operating, air may be entrapped in the fuel distribution system. If this happens, bleeding of the fuel system may be necessary. Refer to the instruc- tions in the MAINTENANCE section of ...

  • Lincoln Electric 11135 - page 14

    B-3 OPERA TION B-3 CLASSIC 300G AUXILIARY POWER The AC auxiliary power, supplied as a standard, has a rating of 3.0 kVA of 115/230 VAC (60 hertz). With the 3.0 kVA, 115/230 VAC auxiliary power, one 115V duplex and one 230V duplex, grounding type receptacle are provided. The circuit is protected with circuit breakers. The rating of 3.0 kVA permits a ...

  • Lincoln Electric 11135 - page 15

    C-1 ACCESSORIES C-1 CLASSIC 300G OPTIONAL EQUIPMENT (Field Installed) Accessory Set (K704) - Includes 35 ft. (10.7m) elec- trode and 30 ft. (9.1m) work cables, headshield, work clamp and electrode holder. Pipe Thawing with an arc welder can cause fire, explosion, damage to electric wiring or to the arc welder if done improperly. The use of an arc w ...

  • Lincoln Electric 11135 - page 16

    D-1 MAINTENANCE D-1 SAFETY PRECAUTIONS GENERAL INSTRUCTIONS • Blow out the welder and controls with an air hose at least once every two months. In particularly dirty locations, this cleaning may be necessary once a week. Use low pressure air to avoid driving dirt into the insulation. • ”Current Range Selector” contacts should not be greased ...

  • Lincoln Electric 11135 - page 17

    D-2 MAINTENANCE D-2 Replace brushes when they wear within 1/4” of the pigtail. A complete set of replacement brushes should be kept on hand. Lincoln brushes have a curved face to fit the commutator. Have an experienced mainte- nance man seat these brushes by lightly stoning the commutator as the armature rotates at full speed until contact is mad ...

  • Lincoln Electric 11135 - page 18

    D-3 D-3 CLASSIC 300G MAINTENANCE ENGINE SERVICE EVERY DAY OR EVERY 8 HOURS F I RST SERV ICE - (50 HOURS) EVERY 100 HOURS OR 3 MONTHS EVERY 200 HOURS OR 6 MONTHS EVERY 600 HOURS OR 12 MONTHS EN GINE SERVICE (NOTE 2) MAINTENANCE ITEM TYPE OR QUANTITY I Coolant l evel I Conc 50/50 Water/Ethylene Glycol e n tration of antifr eeze I Radiator for contam ...

  • Lincoln Electric 11135 - page 19

    E-1 TROUBLESHOOTING CLASSIC 300G E-1 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION ELECTRIC SHOCK can kill. • Do not touch electrically live parts such a ...

  • Lincoln Electric 11135 - page 20

    E-2 TROUBLESHOOTING CLASSIC 300G E-2 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS P ...

  • Lincoln Electric 11135 - page 21

    E-3 TROUBLESHOOTING E-3 CLASSIC 300G Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION FLASHING T ...

  • Lincoln Electric 11135 - page 22

    E-4 TROUBLESHOOTING CLASSIC 300G E-4 ELECTRONIC IDLER CONTROL TROUBLESHOOTING GUIDE Engine Will Not Return to Low Idle in Approximately 10 Seconds After Welding and Auxiliary Loads are Removed Set Idler Control Switch to the Auto Position Check for Continuity through Idler Control Switch Open Closed Remove Molex connector Replace Idler from current ...

  • Lincoln Electric 11135 - page 23

    E-5 TROUBLESHOOTING CLASSIC 300G E-5 ELECTRONIC IDLER CONTROL TROUBLESHOOTING GUIDE With Idler Control Switch in the AUTO Position,Engine Will Not Pick Up Speed When: Auxiliary Load 1. Load too small. Try load above 150 Watts. 2. Check for loose or disconnected wire running from black lead out of exciter to CB2 circuit breaker. The Arc is Struck Ch ...

  • Lincoln Electric 11135 - page 24

    E-6 TROUBLESHOOTING CLASSIC 300G E-6 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENTS(S) RECOMMENDED COUR ...

  • Lincoln Electric 11135 - page 25

    E-7 TROUBLESHOOTING CLASSIC 300G E-7 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION Observe all Safety Guidelines detailed throughout this manual PROBLEMS ( ...

  • Lincoln Electric 11135 - page 26

    E-8 TROUBLESHOOTING E-8 CLASSIC 300G Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ( ...

  • Lincoln Electric 11135 - page 27

    F-1 DIAGRAMS F-1 CLASSIC 300G NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number ...

  • Lincoln Electric 11135 - page 28

    F-2 DIAGRAMS F-2 CLASSIC 300G NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number ...

  • Lincoln Electric 11135 - page 29

    F-3 DIAGRAMS F-3 CLASSIC 300G S26097 A RESIST ORS Y X B G W F G ORANGE WHITE JUMPER WHITE JUMPER PIN CA BLE CONNEC TION TABLE C D E LEAD COLOR RED BLUE CV "WIRE" CONTROL POT CCW BLUE RED ORANGE REMOTE CONTROL BOX CONNECT TO CA SE K2 46 4 -1 REMOTE CONT ROL WIRI NG / CONNECT I ON DI AGRAM CC "STICK CONTROL ...

  • Lincoln Electric 11135 - page 30

    F-4 DIAGRAMS F-4 CLASSIC 300G PART NO. WELDER A B C D E F G H S10766-9 J K L CLASSIC 300G S10766 1/03 METRIC cm (ENGLISH in.) 170.0 (66.91) 146.6 (57.70) 22.1 (8.70) 58.4 (23.00) 67.0 (26.38) 34.3 (13.50) 105.8 (41.66) 8.26 (3.25) 115.6 (45.5) A CONTROL PANEL F G B H D E C O HOLE O MOUNTING HOLE N.A. N.B. NOTES: OIL AND WATER IN ENGINE, BUT NO FUEL ...

  • Lincoln Electric 11135 - page 31

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA EL ...

  • Lincoln Electric 11135 - page 32

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric 11135 - page 33

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabricant Lincoln Electric Catégorie Welder

Les documents que nous recevons du fabricant de l'appareilLincoln Electric 11135 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lincoln Electric
- manuels d’utilisations 11135
- fiches produit Lincoln Electric
- dépliants
- ou étiquettes-énergie Lincoln Electric 11135
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lincoln Electric 11135.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lincoln Electric 11135, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lincoln Electric 11135. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lincoln Electric 11135.

Manuel d’utilisation complet de l’appareil Lincoln Electric 11135, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lincoln Electric 11135 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lincoln Electric 11135.

Le manuel d’utilisation complet Lincoln Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lincoln Electric 11135 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lincoln Electric 11135, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLincoln Electric 11135 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lincoln Electric 11135 - qui devraient nous aider dans les premières étapes lors de l'utilisation Lincoln Electric 11135
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lincoln Electric 11135
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lincoln Electric 11135 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lincoln Electric 11135?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lincoln Electric 11135, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lincoln Electric 11135 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)