  • Fluke 561 - page 1

    ® 561 HV A CPr o Infrared Thermometer Users Manual PN 2562924 February 2006 © 2006 Fluke Corp oration, All ri ghts reserved. Pr inted in USA All product names ar e trademarks of their respective c ompanies. ...

  • Fluke 561 - page 2

    LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defect s in material and workmanship for two years from the date of purchase. This warranty do es not cover fuses, disposable batteries, or damage from accident, neglect , misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers ar ...

  • Fluke 561 - page 3

    i Table of Contents Title Page Introducti on ............................................................................................. 1 Contacting Fluke ...................................................................................... 1 Safety Information ................................................................................... ...

  • Fluke 561 - page 4

    561 HVACPro Users Manual ii Measuring Grille, Registe r, or Diffuser Discharge Tempe rature ......... 15 Verifying Thermostat/ Room Sensor Acc uracy .................................... 15 Checking for Blockage in Air-To-Air Evaporators or Condensers........ 15 Checking Superheat on Fixed Restrictor or Capillary Tube Equipped Evapor ators ......... ...

  • Fluke 561 - page 5

    1 561 HVAC PRO Infrared Thermometer Introduction The Fluke Model 561 HVACPro Infrared Thermometer (hereafter, “the Thermometer”) can determine the surface temperature by measuring the amount of infrared energy radiated by the ta rget’s surface or by contact using a thermocouple probe. The Thermomete r was designed specif ically for use in hea ...

  • Fluke 561 - page 6

    561 HVACPro Users Manual 2 Safety Information W Warning A Warning identifies conditi ons and actions that pose haz ards to the user. To avoid el ectrical shock or personal injury, foll ow these guidelines: • * Do not point laser direct ly at eye or indirectly off reflective surfaces. • Before using the Ther mometer inspect the case. Do not use ...

  • Fluke 561 - page 7

    Infrared Thermometer Features 3 A V O I D E X P O S U R E - L A S E R R A D IA T IO N IS E M IT T E D F R O M T H IS A P E R T U R E CA UTION L A S E R R A D IA T IO N - D O N O T S T A R E IN T O B E A M O U T P U T < 1 m W W A V E L E N G T H 6 3 0 - 6 7 0 n m C L A S S 2 ( II ) L A S E R P R O D U C T C O M P L IE S W IT H F D A 2 1 C F R 1 0 ...

  • Fluke 561 - page 8

    561 HVACPro Users Manual 4 AA Batteries (2) Display Function Buttons Laser T rigger Battery Cover efh007f.eps Figure 2. Infrared Th ermometer Display The primary temperature display reports the current or last IR temperature read until the 7-second hold time elapses. The secondary temperature display reports current th ermocouple temperature when a ...

  • Fluke 561 - page 9

    Infrared Thermometer Buttons and Connector 5 3 4 5 6 2 1 8 7 efh01f.eps A Laser “On” symbol B SCAN or HOLD C ° C/ ° F symbol (Celsius/Fahrenheit) D Primary temperature display E Secondary temperature display F Emissivity LO, MED, HI G Temperature values for the MIN, MAX, DIF, KTC. KTC indicates the thermo couple temperature. H Low Battery sym ...

  • Fluke 561 - page 10

    561 HVACPro Users Manual 6 How the Thermometer Works Infrared thermometers m easure the surface tempera ture of an opaque object. The Thermometer’s optics sense infrared energy, whic h is collected and focused onto a detector. The Thermometer’s electronics then translate the information in to a displayed temperature reading which appears on the ...

  • Fluke 561 - page 11

    Infrared Thermometer Operating the Thermometer 7 D:S=12:1 38 mm @ 300 mm 75 mm @ 900 mm 132 mm @ 1500 mm 1.5 " @ 12 " 3 " @ 36 " 5.3 " @ 60 " S D efh005f.eps Figure 5. Distance and Spot Size Field of View Make sure that the target is larger than the spot size . The smaller the target, the closer you should be to it. Se ...

  • Fluke 561 - page 12

    561 HVACPro Users Manual 8 Table 2. Surface Emissi vity Measured Surface Switch Setting Measured Surface Switch Setting Aluminum Iron, Cast Oxidized Low Oxidized High, Medium Alloy A3003 Unoxidized Low Oxidized Low Molten Low Roughened Low Iron, Wrought Brass Dull High Burnished Low Lead Oxidized Low Rough Low Copper Oxidized Low, Medium Oxidized M ...

  • Fluke 561 - page 13

    Infrared Thermometer Operating the Thermometer 9 Switch efh012f.eps Figure 7. Switching Bet ween ° C and ° F Using the Contact Temperature Probe XW  Warning To avoid electri cal shock or personal injury, do not connect the optional external probe to l ive electrical circuits. Connect the probe to the input on the t op of the The rmometer. The ...

  • Fluke 561 - page 14

    561 HVACPro Users Manual 10 Table 3 lists recommended Fluke temperatur e probes for use with the Thermometer: Table 3. Recommended Tem perature Probes Probe Usage 80PK-25 The piercing probe is the most versatile option. Good for checking air temperature in ducts, surface temperature under carpets/pads, liquids, thermometer wells, vent temperatures, ...

  • Fluke 561 - page 15

    Infrared Thermometer Typical Measurements 11 • The most likely conditions for condensation form ation are low dry bulb te mperat ure and high wet bulb temperature (low temperat ure, high relat ive humidity). • Use the Fluke 971 to measure the attic/crawlspace relative humidity and determine the dew point temperature. This is the temperature at ...

  • Fluke 561 - page 16

    561 HVACPro Users Manual 12 Testing Contactors (Starters) 1. Press D to select emissivity. Press A to select LO for bright c ontacts, or MED for darkened contacts. 2. Press C and the press A to select MAX. 3. Measure line and load side of one pole without releasing trigger. 4. A temperature difference between th e line and load sides of a pole indi ...

  • Fluke 561 - page 17

    Infrared Thermometer Typical Measurements 13 Testing Bearings W Warning To avoid injury when t esting bearings: • Do not wear loose clothi ng, jewelry, or anything around neck when working around moving parts such as motors, belts, blower, and f ans. • Make sure an electrical di sconnect is within reach a nd operating correctl y and freely. • ...

  • Fluke 561 - page 18

    561 HVACPro Users Manual 14 wall you should find parallel isotherm al rows indicating the location of heat t ubes below the surface. Perpendicular to the outside wall, you should fi nd rising and falling temp erat ures at equal distances. High temperatures indicate you are scanning a heat tube be neath the floor surface, low falling temperature s i ...

  • Fluke 561 - page 19

    Infrared Thermometer Typical Measurements 15 • If system pressure has been incr eased above design settings, this can result in sympto m of trap failure (stuck open). Check steam pressure. 1. Press D and then press A to select HI emissivity for bl ack iron pipe and painted traps. 2. Press C and then press A to select DIF. 3. Aim the Thermometer a ...

  • Fluke 561 - page 20

    561 HVACPro Users Manual 16 • All condenser return bend/hairpi ns should be at or slightly less than condenser saturation temperature. • If a group of return bends/hairpins do not confor m to expected temperatures, that indicates a blocked or restricted distri butor or dist ributor tube. Checking Superheat on Fixed Restrictor or Cap illary Tube ...

  • Fluke 561 - page 21

    Infrared Thermometer Maintenance 17 Maintenance Changing the Battery To install or change the two AA batteries, open the battery compartment and insert the batteries as shown in Figure 2. Cleaning the Lens Blow off loose particles using clean compressed air. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. ...

  • Fluke 561 - page 22

    561 HVACPro Users Manual 18 Specifications Infrared Measurement Range ................................................................ -40 ° C to 550 ° C (-40 ° F to 1022 ° F) Spectral Range ......................................................................... 8 to 14 microns Accuracy ........................................................ ...

Fabricant Fluke Catégorie Thermometer

Les documents que nous recevons du fabricant de l'appareilFluke 561 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Fluke
- manuels d’utilisations 561
- fiches produit Fluke
- dépliants
- ou étiquettes-énergie Fluke 561
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Fluke 561.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Fluke 561, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Fluke 561. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Fluke 561.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Fluke 561, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Fluke 561 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Fluke 561.

Le manuel d’utilisation complet Fluke, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Fluke 561 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Fluke 561, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFluke 561 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Fluke 561 - qui devraient nous aider dans les premières étapes lors de l'utilisation Fluke 561
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Fluke 561
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Fluke 561 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Fluke 561?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Fluke 561, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Fluke 561 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image