    Operation Manual Smart-UPS ® Uninterruptible Power Supply 750/1000/1500/2200/3000 V A T ower 100/120/230 V ac 500 V A T ower 100 V ac ...

  • APC Smart-UPS 1000VA LCD 120V US - page 2

    ...

  • APC Smart-UPS 1000VA LCD 120V US - page 3

    1 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 500 V A to 3000 V A T ower is a high perform ance uninterruptible power supply (UPS). It provides pr otection for electronic equipment from utility power blackouts, brownouts, sags, and surges, sm ...

  • APC Smart-UPS 1000VA LCD 120V US - page 4

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 2 Product Overview Front p anel features Rear p a nel features 500 V A to 15 00 V A models  Display interface 500/750/1000/1 500 V A 2200/3000 V A  Bezel  Battery  Internal battery connector  USB port 500/750 V A 100 V ac 750 V A 120 V ac 750 V A 230 V ac  ...

  • APC Smart-UPS 1000VA LCD 120V US - page 5

    3 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Rear p a nel features 2200 V A and 30 00 V A models Inst allation For UPS installation information, refer to the Smart-UPS Installation Guide 750/1000/1500/2200/3000 V A 100/120/230 V ac, 500 V A 100 V ac T ower, that is included with the UPS. The Installation guide is a ...

  • APC Smart-UPS 1000VA LCD 120V US - page 6

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 4 Operation Connect Equipment Note: The UPS will char ge to 90% capacity in th e first four and a half hours of normal operation for the 2200/3000 V A 100 V ac model or the first three hours of normal operation for all other models . Do not expect full battery runtime capabi ...

  • APC Smart-UPS 1000VA LCD 120V US - page 7

    5 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Display Panel Using the display interface Use the U P and D OWN keys to scroll through th e main menu options. Press E NTER to view the sub-menus under each main menu option. Press E SCAPE to exit a sub-menu and return to a main menu. St andard menus The Standard menus a ...

  • APC Smart-UPS 1000VA LCD 120V US - page 8

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 6 Advanced menus The Advanced menus provid e additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. Menu General Functions St a t u s V iew detailed UPS information: • Operating Mode • Eff iciency • Load ...

  • APC Smart-UPS 1000VA LCD 120V US - page 9

    7 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Configuration UPS Settings St art-up Settings Configure these settings at initial start-up, using the di splay interface. As an a lternative, configuration can be performed using APC PowerChute ® software. Note: During start-up, use the display interface to configure th ...

  • APC Smart-UPS 1000VA LCD 120V US - page 10

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 8 Low T ransfer Point 100 V ac: 92 V ac 86 V ac - 92 V ac Set the transfer point lower if the utility voltage is chronically low and the connected equipment can tolerate this cond ition.This setting may also be a djusted using the power quality setting. Note: Use the Advance ...

  • APC Smart-UPS 1000VA LCD 120V US - page 11

    9 Smart-UPS 750/1000/1500/22 00/3000 VA 1 00/120/230 Vac 50 0 VA 100 Vac Tower Main Outlet Group and Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Grou p can be configured to independently turn of f, turn on, shut down, and reboot connecte d equipment. (These features are not available on the 500 V A or 750 V A units. ...

  • APC Smart-UPS 1000VA LCD 120V US - page 12

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 10 Customize the Main and Switched Outlet Groups Use the Configuration menus to change the Main Outlet Gro up and the Switched Ou tlet Group settings. Network Management Card Settings These settings are available only on units that have a Ne twork Management Card (NMC) and a ...

  • APC Smart-UPS 1000VA LCD 120V US - page 13

    11 Smart-UPS 750/1000/1 500/2200/3000 VA 1 00/120/2 30 Vac 500 VA 100 Vac Tower Emergency Power Off Overview The Emergency Power Off (EPO) optio n, is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r . Adhere to all national and l ...

  • APC Smart-UPS 1000VA LCD 120V US - page 14

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 12 T r oubleshooting Prob lem and Possible Cause Solution The UPS will not turn on or there is no output. The unit has not been turned on. Press the ON key once to turn on the UPS. The UPS is not connected to utility power . Be sure the power cabl e is securely connected to ...

  • APC Smart-UPS 1000VA LCD 120V US - page 15

    13 Smart-UPS 750/1000/1 500/2200/3000 VA 1 00/120/2 30 Vac 500 VA 100 Vac Tower Service If the unit requires service, do not retu rn it to the dealer . Follow these steps: 1. Review the T r ou bleshooting section of the manual to eliminate common problems. 2. If the problem persists, contact APC Cust omer Support through the APC W eb site, www .apc ...

  • APC Smart-UPS 1000VA LCD 120V US - page 16

    Smart-UPS 750/1000/1500/2200/3000 VA 100/ 120/230 Vac 500 VA 100 Vac Tower 14 Smart-UPS Factory W arranty LIMITED W ARRAN TY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from dat ...

  • APC Smart-UPS 1000VA LCD 120V US - page 17

    ...

  • APC Smart-UPS 1000VA LCD 120V US - page 18

    2/2012 990-3534C APC W orldwide Customer Support Customer support for this or any other APC product is available at no char ge in any of the follow ing ways: • V isit the APC W e b site to acce ss documents in the APC Knowledg e Base and to submit customer support requests. – www .apc.com (Corporate Headquarters) Connect to localized APC W eb s ...

Fabricant APC Catégorie Uninterruptible power supply (

Les documents que nous recevons du fabricant de l'appareilAPC Smart-UPS 1000VA LCD 120V US peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques APC
- manuels d’utilisations Smart-UPS 1000VA LCD 120V US
- fiches produit APC
- dépliants
- ou étiquettes-énergie APC Smart-UPS 1000VA LCD 120V US
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation APC Smart-UPS 1000VA LCD 120V US.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation APC Smart-UPS 1000VA LCD 120V US, manuels d’entretien, brefs manuels ou manuels de l’utilisateur APC Smart-UPS 1000VA LCD 120V US. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit APC Smart-UPS 1000VA LCD 120V US.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil APC Smart-UPS 1000VA LCD 120V US, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser APC Smart-UPS 1000VA LCD 120V US par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs APC Smart-UPS 1000VA LCD 120V US.

Le manuel d’utilisation complet APC, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel APC Smart-UPS 1000VA LCD 120V US - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières APC Smart-UPS 1000VA LCD 120V US, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAPC Smart-UPS 1000VA LCD 120V US qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil APC Smart-UPS 1000VA LCD 120V US - qui devraient nous aider dans les premières étapes lors de l'utilisation APC Smart-UPS 1000VA LCD 120V US
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de APC Smart-UPS 1000VA LCD 120V US
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service APC Smart-UPS 1000VA LCD 120V US dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de APC Smart-UPS 1000VA LCD 120V US?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec APC Smart-UPS 1000VA LCD 120V US, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec APC Smart-UPS 1000VA LCD 120V US il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)