    USER GUIDE AND SPECIFICATIONS NI USB-6525 This user guide describes how to use the National Instruments USB-6525 data acquisi tion (D A Q) de vice. Introduction The NI USB-6525 is a full-speed USB 2.0 device that provides eight ±60 VDC chan nel-to-channel isolated digital inputs (DI ), eight 60 VDC/30 Vrms channel-to-channel isolated solid-state r ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 2

    USB-6525 User Guide an d Specifications 2 ni.com Figure 2. USB-6525 Back View Installing Software Software suppo rt for the USB-6525 for Wind ows 2000/XP is provided by NI-DAQmx. The NI-D A Q mx CD contains example programs th at you can use to get started programming with the USB-65 25. Refer to the NI-D AQmx for USB Devices Getting Started Guide ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 3

    © National Instruments Co rporation 3 USB-6525 User Guide and Specifications Refer to the Safety G uidelines section of this document for im portant safety information. Setting Up Hardware Complete the f ollowing st eps to set up the hardwa re: 1. Install combicon scr e w terminal blocks by inserting them into th e combicon jacks. Note The USB-652 ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 4

    USB-6525 User Guide an d Specifications 4 ni.com I/O Connector The USB-6525 device ships with two d etachable terminal blocks for digital signals. Each indivi dual terminal accepts a wire gauge between 16 AWG–28 AWG. Table 1. Digital T erminal Assignments Module T erminal Signal Module T erminal Signal 1 P0.0A 17 P1.0+ 2 P0.0B 18 P1.0– 3 P0.1A ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 5

    © National Instruments Co rporation 5 USB-6525 User Guide and Specifications Signal Descriptions Table 2 describes the signals available on the I/O connectors. Digital I/O USB-6525 has eight channel-to-channel op tically isolated inputs, P1.<0..7>, and eight chann el-to-channel optically isolated solid-state relay outputs, P0.<0..7>. P ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 6

    USB-6525 User Guide an d Specifications 6 ni.com Applying a DC voltage of at least 3.2 V across two input terminals registers logic high. Applying no voltage or a voltage dif ference of 1 V or less registers logic lo w . DC voltages between 1 V and 3.2 V may not register a consistent or usable value. Signal Connection Example Figure 5 shows signal ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 7

    © National Instruments Co rporation 7 USB-6525 User Guide and Specifications Solid-State Relay (SSR) Outputs You can connect loads to the USB-6525. Connect the load to one of the leads of the power source. Connect either the P0. x A or the P0. x B terminal to the load and the other terminal to the other lead of the AC or DC power source. Figure 6 ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 8

    USB-6525 User Guide an d Specifications 8 ni.com Figures 7 and 8 show examples of us ing an external flyback diode to protect DC inductiv e loads and an MO V to protect A C inducti ve loads, respecti vely . Figure 7. Contact Protection for DC Inductive Load s Figure 8. Co ntact Protection for AC Inductive Loads Inductive Load USB-6525 Flyback Diode ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 9

    © National Instruments Co rporation 9 USB-6525 User Guide and Specifications Using the USB-6525 as a TTL Output Device Figure 9 shows a sign al connection example for a TTL-level application with an external supply voltage of +5 V. Figure 9. TTL Device Signal C onnection Example When the SSR is open, a small am ount of current flo ws through R L a ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 10

    USB-6525 User Guide an d Specifications 10 ni.com Input current ........... .............. .............. ....3.0 mA/channel max Solid-State Relay Outputs Number of output channels ................. ....8, ch-ch isolated Relay type ..................... .............. ............Normally open solid-state relay (SSR) Switching voltage ............. ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 11

    © National Instruments Corporation 11 USB- 6525 User Guide an d Specifications Power Requirements USB Input voltage ............ ........... ............ 4.5 to 5.25 VDC in configured state Active current ....... .............. ........... . 150 mA max Suspend current...................... ......... 350 μ A ty p Physical Characteristics Dimension ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 12

    USB-6525 User Guide an d Specifications 12 ni.com Isolation Channel-to-channel ............. .............. ......60 VDC continuous Channel-to-earth ground ....... ...... ............60 VDC continuous Withstand . .......... .............. ........... ............60 VDC continuous Caution Do not use this module for connection to signals or for measu ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 13

    © National Instruments Corporation 13 USB- 6525 User Guide an d Specifications CE Compliance This product meets the essential re quirements of applicable European Directives, as amended for CE markin g, as follows: • 73/23/EEC; Lo w-V oltage Directi ve (safety) • 89/336/EEC; Electromag netic Compatibility Directive (EMC) Note Refer to the Decl ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 14

    USB-6525 User Guide an d Specifications 14 ni.com Operate the device only at or belo w Pollution Degree 2. Pollution is foreign matter in a solid, liquid, or gaseous state that can reduce dielectric strength or surface resisti vity . The following is a description of pollution de grees: • Pollution Degree 1 means no pollution or only dry , noncon ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 15

    © National Instruments Corporation 15 USB- 6525 User Guide an d Specifications • Measurement Category III is for measurements performed in the building installation at the distribution le vel. This cate gory refers to measurements on hard-wir ed equipment such as equipment in f ixed installations, distribution boards, and circuit breakers. Other ...

  • National Instruments USB-6525 data aquisition (DAQ) device - page 16

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more information abou t National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or t rade names of their respective companie s . For patents covering Nati ...

Fabricant National Instruments Catégorie Marine RADAR

Les documents que nous recevons du fabricant de l'appareilNational Instruments USB-6525 data aquisition (DAQ) device peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques National Instruments
- manuels d’utilisations USB-6525 data aquisition (DAQ) device
- fiches produit National Instruments
- dépliants
- ou étiquettes-énergie National Instruments USB-6525 data aquisition (DAQ) device
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation National Instruments USB-6525 data aquisition (DAQ) device.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation National Instruments USB-6525 data aquisition (DAQ) device, manuels d’entretien, brefs manuels ou manuels de l’utilisateur National Instruments USB-6525 data aquisition (DAQ) device. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit National Instruments USB-6525 data aquisition (DAQ) device.

Manuel d’utilisation complet de l’appareil National Instruments USB-6525 data aquisition (DAQ) device, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser National Instruments USB-6525 data aquisition (DAQ) device par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs National Instruments USB-6525 data aquisition (DAQ) device.

Le manuel d’utilisation complet National Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel National Instruments USB-6525 data aquisition (DAQ) device - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières National Instruments USB-6525 data aquisition (DAQ) device, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNational Instruments USB-6525 data aquisition (DAQ) device qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil National Instruments USB-6525 data aquisition (DAQ) device - qui devraient nous aider dans les premières étapes lors de l'utilisation National Instruments USB-6525 data aquisition (DAQ) device
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de National Instruments USB-6525 data aquisition (DAQ) device
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service National Instruments USB-6525 data aquisition (DAQ) device dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de National Instruments USB-6525 data aquisition (DAQ) device?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec National Instruments USB-6525 data aquisition (DAQ) device, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec National Instruments USB-6525 data aquisition (DAQ) device il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)