Manuel d’utilisation Energizer ATX612

17 pages 0.28 mb
Télécharger

Aller à la page of 17

Summary
  • Energizer ATX612 - page 1

    P/N 1706-3421 REV 03 Printed 0900-2000 Specifications Subject to Change 1001 Oakdale Road, Oakdale, P A 15071-1500 (412) 788-4353 • T oll Free 1-800-DETECTS F AX 412-788-8353 • Service Dept. 1-888-788-4353 Multi-Gas Monitor AT X 612 Instruction Manual GUARANTEED. FOR LIFE. INDUSTRIAL SCIENTIFIC CORPORATION ...

  • Energizer ATX612 - page 2

    OUR MISSION Design - Manufactur e - Sell: Highest quality pr oducts for the pr eservation of life and pr operty . Pr ovide: Best customer service available. ...

  • Energizer ATX612 - page 3

    Dear V alued Customer , Thank you for buying and using Industrial Scientific’ s Model A TX612 Multi-Gas Monitor . Y our A TX612 can be relied upon for dependable service, day after day . It has been designed, manufactured, tested and proven under the most scrutinizing conditions possible. W ith the minimal care and maintenance described in this I ...

  • Energizer ATX612 - page 4

    Multi-Gas Monitor AT X 612 1. W ARNINGS AND C AUTIONAR Y S T A TEMENTS 3 2. U NP ACKING T HE I NSTRUMENT 4 3. A TX612 F EA TURES 4 4. I NSTRUMENT O PERA TION 5 4 .1 Charging the Battery 5 4.1.1 Alkaline Battery Option 8 4 .2 T urning the A TX612 On and Off 8 4.3 Display Backlight 8 4.4 Internal Sampling Pump 8 4.5 Operating Modes 9 4.5.1 Reading 9 ...

  • Energizer ATX612 - page 5

    4 5 2. U NP ACKING THE I NSTRUMENT The shipping box should contain the following items. Account for each item before discarding the box. Q UANTITY P AR T N UMBER D ESCRIPTION 1 1810-2707 A TX612 Multi-Gas Monitor 1 1706-3421 A TX612 Instruction Manual 1 1706-3256 Maintenance T ool 1 1810-0628 Shoulder Strap 1 1810-3077 Charging Adapter (with Nicad ...

  • Energizer ATX612 - page 6

    INDUSTRIAL SCIENTIFIC ATX612 OXYGEN LEL E BATT PPM % ON/OFF MODE 6 7 Hidden (+) Key Alarm Speaker On/Off/Mode Key Ultra-bright V isual Alarm Light Bar Battery Status Indicator Hidden (-) Key Display Enter/Backlight Key Char ging Socket (Nicad V ersions) Infrar ed Data Interface Gas Sample Inlet Fitting Pump Exhaust Port Shoulder Strap/ Optional Han ...

  • Energizer ATX612 - page 7

    8 9 CO H2S 02 LEL ATX612 VER 1.0 5 O 0 21.0 0 The remote sample tube should be connected to the barbed inlet fitting on the bottom of the A TX612 (See Figure 3). NOTE: When drawing a r emote sample, allow 2 seconds per foot (0.3 meter) of tubing length in addition to the normal sensor r esponse time befor e observing the instrument r eadings. The i ...

  • Energizer ATX612 - page 8

    10 11 4.6.2 HIGH ALARM When a monitored gas concentration reaches the high alarm level setpoint, the instrument emits a continuous dual tone alarm. As with the low alarm condition, the red alarm light bar and backlight will flash simultaneously with the displayed gas value. If the hygiene/datalogging option is installed, the STEL alarm will mimic t ...

  • Energizer ATX612 - page 9

    12 13 ZERO PRESS ZEROING 21.0 02 CAL 4.6.6 BA TTER Y F AILURE When the battery has insufficient char ge to operate the instrument, “BA TTER Y F AIL” is displayed. The visual alarm will be activated and the instrument will emit a short beep once every second for approximately 30 seconds after which the instrument will turn itself off. Recharge o ...

  • Energizer ATX612 - page 10

    14 15 CODE 0 PRESS • T o continue full calibration, press (E) and the instrument will display the first sensor to be calibrated along with the calibration gas setting. The message APPL Y CAL GAS will scroll across the bottom of the display . NOTE: If the gas concentration does not match the setting, pr ess the MODE switch to abort calibration. Se ...

  • Energizer ATX612 - page 11

    16 17 CODE PRESS CODE 123 PRESS • Press (+) to step to the INST ANT function and set instantaneous alarm values. The display will indicate INST ANT along with the scrolling prompt PRESS (+) FOR NEXT (E) TO SELECT . • Press (E) to enter the instantaneous alarms function. The display will show the first alarm to be set along with the scrolling pr ...

  • Energizer ATX612 - page 12

    18 19 The datalogging section of the instrument is always powered and a battery backup circuit protects it from loss of data for up to 40 minutes during battery changes. NOTE: The instrument must be stor ed on a battery char ger when not in use to pr event loss of data due to battery dischar ge. 7.3 R ESETTING THE H YGIENE F UNCTIONS NOTE: If you a ...

  • Energizer ATX612 - page 13

    20 21 • Remove the battery pack from the instrument as described in Section 8.2. • Remove the two screws which hold the battery module in place as shown in Figure 4. • Lift the Nicad battery module from the battery pack. • Place the new Nicad module in the battery pack. • Replace the two screws which hold the Nicad module in place. 8.2.2 ...

  • Energizer ATX612 - page 14

    22 23 I TEM P ART N UMBER D ESCRIPTION (Q TY ) 1 1705-8868 Main PC Board (1) 2 1705-6755 Display PC Board (1) 3 1705-9247 Interface PC Board (1) 4 1705-9031 Chassis (1) 5 1706-3447 Pump Assembly (1) 6 1705-9494 Nicad Battery Pack or 1705-9312 Alkaline Battery Pack 7 1706-0716 Case Gasket (1) 8 1706-2498 Filter Housing (1) 9 1705-8157 Dust Filter/W ...

  • Energizer ATX612 - page 15

    24 25 ...

  • Energizer ATX612 - page 16

    27 26 11 . D EF AUL T A LARM S ETTINGS GAS LOW ALARM HIGH ALARM O 2 19.5% 23.5% LEL 10% 20% CH 4 1.0% 1.5% CO 35 PPM 70 PPM H 2 S 10 PPM 20 PPM SO 2 2.0 PM 4.0 PPM NO 2 3.0 PPM 6.0 PPM Cl 2 0.5 PPM 1.0 PPM ClO 2 0.3 PPM 1.0 PPM NOTE: Factory alarm settings may not coincide with local r egulations. Consult all appr opriate local r egulations for app ...

  • Energizer ATX612 - page 17

    28 29 Industrial Scientific portable gas monitoring instruments are warranted to be free from defects in material and workmanship for as long as the instrument is in service. The above warranty does not include sensors, battery packs, internal pumps or filters, all of which are warranted to be free from defects in material and workmanship for eight ...

Fabricant Energizer Catégorie Computer Monitor

Les documents que nous recevons du fabricant de l'appareilEnergizer ATX612 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Energizer
- manuels d’utilisations ATX612
- fiches produit Energizer
- dépliants
- ou étiquettes-énergie Energizer ATX612
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Energizer ATX612.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Energizer ATX612, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Energizer ATX612. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Energizer ATX612.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Energizer ATX612, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Energizer ATX612 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Energizer ATX612.

Le manuel d’utilisation complet Energizer, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Energizer ATX612 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Energizer ATX612, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEnergizer ATX612 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Energizer ATX612 - qui devraient nous aider dans les premières étapes lors de l'utilisation Energizer ATX612
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Energizer ATX612
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Energizer ATX612 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Energizer ATX612?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Energizer ATX612, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Energizer ATX612 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)