Agilent 6800 Series AC Power Source/Analyzer Product Note Using the Agilent T echnologies 6800 Series AC Power Source/Analyzers for Generation and Measurement Applications: • Simulating A C Line Sub-Cycle Dr opouts • Generating MIL -STD-704D W a vef orms • P er forming IEC 555-2 Measurements • P er forming Inrush Cur rent Measurements • G ...
-
Agilent Technologies 6800 - page 2
2 3 4 6 8 11 14 18 21 24 28 Introduction This note pro vides information on ho w you can use the features of the Agilent Technologies 6800 series ac po wer source/anal yzers to address a variety of applications. Although your exact appli- cation may not be listed here, the capabilities described can be generalized and applied to your specific needs ...
-
Agilent Technologies 6800 - page 3
3 The 6800 series ac po wer source/anal yzers are members of the A gilent T echnologies “One-Bo x” Solution po wer products famil y. These products offer an integrat ed solution f or ac pow er testing applications. The 6800 series combines the functionality of the follo wing instruments in one bo x: • po wer am plif ier • arbitrar y wav efo ...
-
Agilent Technologies 6800 - page 4
4 A programmable output value of the ac pow er source/analyzer can operate in one of f our modes: FIXED, Step, Pulse, or List. The default setting is FIXED mode, where the output will st a y “f ix ed” at the programmed value until anot her command is sent to change it. The remaining three operating modes constitute the T ransient Subsystem. Out ...
-
Agilent Technologies 6800 - page 5
5 Model of the T ransient System ...
-
Agilent Technologies 6800 - page 6
6 In A TE applications, triggers are of ten a conven- ient way of synchr onizing test syst em ev ents and increasing test throughput. These benef its also apply to the triggering subsystems in t he 6800 series products since these products combine the capabilities of many test instruments. Each model is equipped with t he ability to send and receiv ...
-
Agilent Technologies 6800 - page 7
7 Output T ransient T rigger Model Measurement T rigger Model ...
-
Agilent Technologies 6800 - page 8
8 The built-in po wer analyzer capability off ers many voltage, current, and pow er measurements to the user . While on, the ac po wer sour ce/analyzers are continuously sam pling inst antaneous output volt- age and current for sev eral output cycles and writ- ing the dat a to buf f ers. Each buf f er , one for v oltage and one for current, holds 4 ...
-
Agilent Technologies 6800 - page 9
9 How Can the Acquisition of V oltage and Current Data be Controlled? T w o characteristics of t he voltage and current acquisition can be controlled: the sample rate, and the beginning of acquisition relative to the trigger . The ac po w er source/analyzer has a sample rate of appro ximately 40 kHz (a sample ev er y 25 microseconds) as the default ...
-
Agilent Technologies 6800 - page 10
10 The follo wing section contains six application examples. F or each application, there is: • An o verview of the application • A description of the A gilent 6800 series f eatures used to implement the application • The advantages and benef its of the 6800 series solution • The det ails of t he im plementation of the solution • A sample ...
-
Agilent Technologies 6800 - page 11
11 Overview of application The ability of a switching pow er supply to main- tain its output voltage setting in t he presence of typical ac line disturbances is critical to its end- use. If the end-use of t he po wer suppl y is inst alla- tion into a computer , f or example, sensitivity to ac line variations can result in unexpected loss of critica ...
-
Agilent Technologies 6800 - page 12
12 U pon the receipt of the trigger , the ac source continues to output a 120 V r ms, 60 Hz sinewa ve for 5 seconds. After the 5-second trigger delay , the r ms v olt age drops to 0 V rms at 80° of t he cycle and then rises back to 120 V rms (0.001389 seconds later) at 110° of the cycle. V ariations on this implementation 1. The Pulse width can b ...
-
Agilent Technologies 6800 - page 13
13 ...
-
Agilent Technologies 6800 - page 14
14 Overview of application U .S. Militar y Standard 704D (September 30, 1980) establishes t he requirements of electrical po wer transfer betw een the aircraft or g round support electrical system, and the electronic equipment utilizing this pow er on board the aircraft. When testing to t his standard, electrical aircraft equip- ment must be subjec ...
-
Agilent Technologies 6800 - page 15
15 Agilent 6800 series setup (continued) • Set the List points as follo ws: List Vrms Dwell Point V rms frequency Slew Time 1 115 V 400 Hz INF *60 s 2 127 V 400 Hz INF 0.01 s 3 88 V 400 Hz 566 V/s 0.07 s 4 115 V 400 Hz INF *60 s 5 57 V 400 Hz INF 0.01 s 6 76 V 400 Hz 283 V/s 0.07 s 7 115 V 400 Hz INF *60 s 8 115 V 425 Hz INF 1 s 9 115 V 420 Hz IN ...
-
Agilent Technologies 6800 - page 16
16 List Timing Diagram for Application 2 ...
-
Agilent Technologies 6800 - page 17
17 ...
-
Agilent Technologies 6800 - page 18
18 Overview of application IEC 555-2 (1982) is a regulator y st andard that pert ains to ac line disturbances, namely current harmonics. These cur rent harmonics are caused by connecting household appliances and similar elec- trical equipment to a 230 V , 50 Hz ac mains. This standard est ablishes limits on the amount of har- monic energy electrica ...
-
Agilent Technologies 6800 - page 19
19 Agilent 6800 series setup • The ac source output is connected to the ac input of the equipment under test. • Set the output wav eform to sine. • Set the r ms v olt age to Fixed mode. • Set the frequency to F ix ed mode. • Set the voltage to 230 Vrms. • Set the frequency to 50 Hz. • Set the measurement window to Rectangular . • En ...
-
Agilent Technologies 6800 - page 20
20 ...
-
Agilent Technologies 6800 - page 21
21 Overview of application Swit ch mode pow er supplies are commonly used in many electr onic products. These po wer supplies typically ha ve in put capacit ors that cause high lev els of peak inr ush current to be drawn as they charge from the rectified line at tur n-on. The peak amplitude of the inrush cur rent varies with the turn-on phase of th ...
-
Agilent Technologies 6800 - page 22
22 Agilent 6800 series setup • Set the initial (immediate) voltage t o 0 V rms. • Set the triggered voltage level to 120 V rms. • Set the frequency to 60 Hz. • Set the peak cur rent limit to maximum. • Set the transient trigger source to BUS. • Set the trigger synchronization source to Phase. • Set the initial synchronization Phase to ...
-
Agilent Technologies 6800 - page 23
23 ...
-
Agilent Technologies 6800 - page 24
24 Overview of application The creation of user -def ined wa vef or ms is useful for simulating ac line disturbances that are unique to the operational environment of the device being tested, and t hen measuring that device’s suscepti- bility to the disturbance. This is t he fundamental objective of envir onment al test st andards that per- tain ...
-
Agilent Technologies 6800 - page 25
25 Agilent 6800 series setup • Connect the ac source output to the ac input of the equipment under test. • Use the computer to develop a 1024 point array representing a cy cle of voltage amplitude data. • Use the TR A Ce:DEFine command to name t he wav eform CL ASS 1 and allocate non-volatile storage space. • Use the TRACe:D ATa command to ...
-
Agilent Technologies 6800 - page 26
26 ...
-
Agilent Technologies 6800 - page 27
27 ...
-
Agilent Technologies 6800 - page 28
28 Overview of application F or some applications, such as the simulation of European railwa y po wer systems, a lo w frequency (16.6 Hz) ac wav eform is required. Generating lo w frequency wav eforms with ac sources can present testing challenges due to output pow er derating and programming inaccuracies, depending on the regulation technique used ...
-
Agilent Technologies 6800 - page 29
29 ...
-
Agilent Technologies 6800 - page 30
Agilent T echnologies’ T est and Measurement Support, Services, and Assistance A gilent Technologies aims to maximize the value you receiv e, while minimizing your risk and pr oblems. W e strive to ensure that you get the test and measurement capabilities you paid for and obtain the suppor t y ou need. Our extensive suppor t resources and service ...
Avez-vous une question à propos de Agilent Technologies 6800?
Utiliser le formulaire ci-dessous
Si vous n’avez pas résolu votre problème avec Agilent Technologies 6800, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Agilent Technologies 6800 il est probable qu’il a envie de partager la façon de le résoudre.