Manuel d’utilisation Zephyr ZNA-M90S

21 pages 1.34 mb
Télécharger

Aller à la page of 21

Summary
  • Zephyr ZNA-M90S - page 1

    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: MAR09.0102 © Zephyr Corporation Napoli Island ZNA-M90S ZNA-E42S ...

  • Zephyr ZNA-M90S - page 2

    www .zephyronline.com ...

  • Zephyr ZNA-M90S - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr ZNA-M90S - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr ZNA-M90S - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat ...

  • Zephyr ZNA-M90S - page 6

    List of Materials 4 www .zephyronline.com (3) Wire Nuts (1) Suction Cup (4) ø12 OD / ø5 ID W ashers (4) M4 x 1-1/2” Wood Screws (2) M4 x 8 Philips Head Screws 1 - Hardware package 1 - Top support frame 1 - Bottom support frame 1 - Top duct cover 1 - Bottom duct cover 1 - Hood body 3 - Metal mesh filters 4 - 50W GU-10 halogen lights 1 - 6” rou ...

  • Zephyr ZNA-M90S - page 7

    5 Duct pieces To t a l Equivalent number length x used = 3- 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 8” Round, straight 1 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 90 0 elb ow 15 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 90 0 flat elb ow 24 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. wall ...

  • Zephyr ZNA-M90S - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round ducting must be used to maintain maximum air fl ow ef fi ciency . Always use rigid type metal ducts only . Flexible ducts could restrict air fl ow by up to 50%. Use calculation worksheet to compute total duct work. AL WA YS, when possible, re ...

  • Zephyr ZNA-M90S - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . Fasten all connections with sheet metal screws and tape all joints w/ certi fi ed Silver T ...

  • Zephyr ZNA-M90S - page 10

    8 www .zephyronline.com Installation – Hood Speci fi cations 35 7 16 " /42"[1065] 900 Min 32 1 2 " 826 Max 49"[1244] 11 13 16 " 300 25 9 16 " 650 1 9 16 " 40 9 13 16 " 249 8 9 16 " 218 6 1 8 " 155 8 3 16 " 208 6 13 16 " 173 10 3 16 " 258 1 1 8 " 28 front of hood side of hood t ...

  • Zephyr ZNA-M90S - page 11

    9 Add Blockings Fasten Support Frame Install Duct Cover Fasten upper duct cover Adjust height & fasten frame 1. Add and secure blocking (minimum 2x4 studs onto ceiling joists. 2. Fasten mounting telescopic support frame directly onto ceiling joist or stud blockings. 3. Adjust height requirement and fasten support frames together . NOTE: If reci ...

  • Zephyr ZNA-M90S - page 12

    10 www .zephyronline.com Mount hood onto support frame 6. Lift lower duct cover and hood body onto bottom of support frame. 7. Secure hood body to bottom support with (4) screws. Access the screws from inside the hood. This will require at least two people. Installation – Mounting the Hood WARNING: Electrical wiring must be done by a qualified pe ...

  • Zephyr ZNA-M90S - page 13

    11 Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then puri fi ed and re- circulated bac ...

  • Zephyr ZNA-M90S - page 14

    12 www .zephyronline.com Lights On/Dim/Off 15 Min Delay Off Display (speed level, delay off, filter clean/change) Adjust 6 Speed Levels Blower On/Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 3. 2. Speed Selection The 6 speed levels are selected by pressing to decrease and ...

  • Zephyr ZNA-M90S - page 15

    Features & Controls – Charcoal Filter Change Reminder 13 Charcoal Filter Change Reminder (charcoal filter , if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home. These charcoal filters are required to ...

  • Zephyr ZNA-M90S - page 16

    Features & Controls – Metal Mesh Filter Clean Reminder 14 www .zephyronline.com Metal Filter Clean Reminder (metal mesh filter) Whether your hood is installed as an exhaust or purifying unit, a set if metal mesh filters are fitted by the factory , These metal mesh filters are intended to filter out residue from cooking. They need not be repla ...

  • Zephyr ZNA-M90S - page 17

    15 SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser . After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buf ...

  • Zephyr ZNA-M90S - page 18

    16 www .zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, ...

  • Zephyr ZNA-M90S - page 19

    T roubleshooting 17 TROUBLESHOOTING PROCEDURES FOR NAPOLI ISLAND Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power connection with th ...

  • Zephyr ZNA-M90S - page 20

    18 www .zephyronline.com DESCRIPTION P ART# Replacement Parts Light Bulb GU10 50W (each) Z0B-0020 Metal Filter (each) 50200004 Optional Accessories Recirculating Kit ZRC-0060 Replacement Charcoal Filter (each) Z0F-C002 Duct Cover Extension Z1C-00NA T o order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368 List o ...

  • Zephyr ZNA-M90S - page 21

    1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be fre ...

Fabricant Zephyr Catégorie Ventilation Hood

Les documents que nous recevons du fabricant de l'appareilZephyr ZNA-M90S peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Zephyr
- manuels d’utilisations ZNA-M90S
- fiches produit Zephyr
- dépliants
- ou étiquettes-énergie Zephyr ZNA-M90S
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Zephyr ZNA-M90S.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Zephyr ZNA-M90S, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Zephyr ZNA-M90S. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Zephyr ZNA-M90S.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Zephyr ZNA-M90S, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Zephyr ZNA-M90S par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Zephyr ZNA-M90S.

Le manuel d’utilisation complet Zephyr, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Zephyr ZNA-M90S - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Zephyr ZNA-M90S, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lZephyr ZNA-M90S qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Zephyr ZNA-M90S - qui devraient nous aider dans les premières étapes lors de l'utilisation Zephyr ZNA-M90S
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Zephyr ZNA-M90S
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Zephyr ZNA-M90S dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Zephyr ZNA-M90S?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Zephyr ZNA-M90S, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Zephyr ZNA-M90S il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)