Manuel d’utilisation Fluke 434

20 pages 0.78 mb
Télécharger

Aller à la page of 20

Summary
  • Fluke 434 - page 1

    ® Fluke 433/434 Three Phase Power Quality Analyzer Getting Started EN August 2004 © 2004 Fluke Corporation , All rights reserv ed. Printed in The Netherlands All product names are trademarks of their respec tive companies. ...

  • Fluke 434 - page 2

    Contents of Analyzer Kit F 1 F 2 F 3 F 4 F 5 Fluke 434 ...

  • Fluke 434 - page 3

    1 Getting Started Introduction This Getting Started manual provides basic i nformation on the Fluke 433 and 434 T hree Phase Power Qualit y Analyzers. Fluke 434 has addition al features such as Interharmonics, Transients, Energy Usage, Inrush Currents, extra memory to store Screens and Data, FlukeView software, and an optical isolated interface cab ...

  • Fluke 434 - page 4

    Fluke 433/434 Getting Started 2 Warning To avoid electrical shock or fire: • Review the entire manual before us e of the Analyzer and its accesso ries. • Avoid working alone. • Do not operate the A nalyzer around explosive gas or vapor. • Use only insulated current pro bes, test leads and adapters as sup plied with the Analyzer, or indicate ...

  • Fluke 434 - page 5

    Getting Started If Safety Features are Impaired 3 Voltage ratings are gi ven as “working voltage”. They should be read as V ac rms (50-60 Hz) for AC sine wave applications and as V dc for DC applications. Measurement Category IV refers to the over head or underground utility serv ice of an installation. Cat III refers to distribution level and ...

  • Fluke 434 - page 6

    Fluke 433/434 Getting Started 4 Subject Page c Charging Batteries, Preparing for Use. 4 d Input Connections. 7 e Auxiliary Functions, Menu Nav igation. 5 f SCOPE Mode. 8 g Measurements MENU. 8 h Power Quality MONITOR. 9 i Screen Symbols. 10 j Screens and Function Keys. 10 k Setting up the Analyzer, SETUP. 16 l MEMORY Use. 18 SAVE Screens. 17 Before ...

  • Fluke 434 - page 7

    Getting Started Tilt Stand 5 Tilt Stand The Analyzer has a tilt st and that allo ws viewing the screen at an angle when placed on a flat sur face. With the tilt stand folded out, the optical port at the right side of the Analyzer can be accesse d. Hang Strap A hang strap is supplied with the Ana lyzer. The figure below shows how to attach the strap ...

  • Fluke 434 - page 8

    Fluke 433/434 Getting Started 6 Brightness: Press to dim or brighten the backlight. Dimmed brightness saves batter y power. For extra brightness keep pressed for 5 seconds. Contrast adjustment of the di splay is e xplained in the next section as a part of ‘Menu Navigation’. Lock keyboard for unattended measurements: ENTER Press for 5 seconds to ...

  • Fluke 434 - page 9

    Getting Started Input Connections 7 Input Connections The Analyzer has 4 BNC-input s for current clamps and 5 banana-inputs for voltages. Self-adhesive decals are supplie d corresponding to wiring color codes used in the USA, Continental Europe, the UK, and China. Stick the decals that fit to your local wiring codes around the current and voltag e ...

  • Fluke 434 - page 10

    Fluke 433/434 Getting Started 8 Measuring Modes, a Quick Overview This section gives an overview of all meas uring modes. The Analyz er’s screen information and use of function keys is explained in more detail in the ne xt two chapters. SCOPE SCOPE MODE. The following features are available: Measuring Mode Screen Type Representa tion of Measuring ...

  • Fluke 434 - page 11

    Getting Started Measuring Modes, a Quick Overview 9 Measuring Mode Screen Type Representa tion of Measuring Results Cursor/Zoom Flicker Table Numerical values: Short/Lon g term flicker, Dc, Dmax, TD No / No Trend Trend over time of values in the table Yes / Yes Unbalance Table Numerical values: Voltage/current unbal ance percentages, Voltage/curren ...

  • Fluke 434 - page 12

    Fluke 433/434 Getting Started 10 Screen Symbols Symbols may appear in the u pper and the lower screen areas to show the state of Analyzer and measurements. Status Indicators in the upper screen area: Time that a measurement has been going on. Format: hours, minutes, seconds. When waiting for a timed start, time counts down with prefix -. Horizontal ...

  • Fluke 434 - page 13

    Getting Started Screens and Function Keys 11 Each screen and its features are explained below. Read this carefully to get acquainted with all functi ons of your Analyzer. TABLE screen 1 3 2 2 This screen gives a quick over view of important numerical measuring values. An example is the table belonging to VOLTS/AMPS/HERTZ mode. Screen information: c ...

  • Fluke 434 - page 14

    Fluke 433/434 Getting Started 12 TREND screen. 1 2 The Trend screen shows the chan ges over time of measuring values on one ro w of the table. An example is the VOLTS/AMPS/HERTZ TRE ND. Time is displaye d horizontally. The displa y is bu ilt up from the right side of the screen. To allow continuou s record ing of data, the time axis is compressed w ...

  • Fluke 434 - page 15

    Getting Started Screens and Function Keys 13 WAVEFORM screen An example is the Scope Waveform screen. Voltag e and current waveforms are displayed similar to an oscilloscope. 2 1 3 Screen information: c The RMS values of the waveforms are displayed in the hea der. d Display of measured frequenc y. e Waveform display area with grid lines at importan ...

  • Fluke 434 - page 16

    Fluke 433/434 Getting Started 14 PHASOR screen. Shows phase relation bet ween voltages and currents in a vector diagram. An example i s the Scope Phasor screen: 1 3 2 Screen information: c RMS values of the waveforms are displayed in the hea der. d Vector diagram. The vector of the reference phase A (L1) points to the positive X-direction. e Additi ...

  • Fluke 434 - page 17

    Getting Started Screens and Function Keys 15 You can use a pre-defined se t of limits or define your own. An example of a pre-def ined set of limits is that according to the EN50160 standar d. Power Quality Monitoring is accessible via the MONIT OR key and a menu for immediate or timed start. Measuring values of the bar graph u nder the cursor are ...

  • Fluke 434 - page 18

    Fluke 433/434 Getting Started 16 Setting up the Analyzer SETUP The SETUP key gives access to a menu to config ure the Analyzer for your measurements. Use the arrow keys to select the item you want to adjust: date, time, wiring configuration, nominal frequenc y, nominal voltage, limits, current and voltage probe type. User ID is adjusted under F4 US ...

  • Fluke 434 - page 19

    Getting Started Save screens. 17 F1 Displayed information l anguage. F2 Information on Analyzer Version, Options and Calibration date. F3 Offset, span and other settings to optimize measurement s. Adjustment during a measurement is possible to enable better viewing of trends and waveforms. F4 Phase Identificati on/Colors, Printer type, RS232 interf ...

  • Fluke 434 - page 20

    Fluke 433/434 Getting Started 18 Memory Use. MEMORY The MEMORY key gives access to a menu to SAVE, RECALL, DELETE Data and Screen co pies and to PRINT. A data file includes screen, trends, tables, settings and limits. You may use cursor and zoom after recall. The function keys allo w the following selections: F1 Access to a submenu to recall/delete ...

Fabricant Fluke Catégorie Stereo System

Les documents que nous recevons du fabricant de l'appareilFluke 434 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Fluke
- manuels d’utilisations 434
- fiches produit Fluke
- dépliants
- ou étiquettes-énergie Fluke 434
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Fluke 434.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Fluke 434, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Fluke 434. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Fluke 434.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Fluke 434, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Fluke 434 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Fluke 434.

Le manuel d’utilisation complet Fluke, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Fluke 434 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Fluke 434, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFluke 434 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Fluke 434 - qui devraient nous aider dans les premières étapes lors de l'utilisation Fluke 434
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Fluke 434
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Fluke 434 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Fluke 434?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Fluke 434, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Fluke 434 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)