Manuel d’utilisation Honeywell Metrologic MS7120 Orbit

52 pages Non applicable
Télécharger

Aller à la page of 52

Summary
  • Honeywell Metrologic MS7120 Orbit - page 1

    METROLOGIC INSTRUMENTS, INC. MS7120 Orbit ® Present ation Laser Scanner Inst allation and User ’ s Guide 00-02408D_unit_7120_Cover_Oct_2005.qxd 10/26/2005 11:31 AM Page 1 ...

  • Honeywell Metrologic MS7120 Orbit - page 2

    Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior w ritten consent, except by review er, who may quote brief passages in a review, or provided for in the Copy right Act of 1976. Products and brand names mentioned in this doc ...

  • Honeywell Metrologic MS7120 Orbit - page 3

    ii T ABLE OF C ONTENTS Introduction ................................................................................................ 1 Scanner and Accessories .......................................................................... 2 Operational Notes ..................................................................................... 3 Installa ...

  • Honeywell Metrologic MS7120 Orbit - page 4

    iii T ABLE OF C ONTENTS Installing the Optional Wall/Counter Mount ............................................. 21 Troubleshooting Guide ............................................................................ 22 RS-232 Demonstration Program ............................................................. 27 Applications and Protocols ........... ...

  • Honeywell Metrologic MS7120 Orbit - page 5

    1 I NTRODUCTION Orbit ® is an aggressive, omnidirectional laser bar code scanner. Lightweight and rugged, Orbit is small in size, but BIG in performance. Designed for applications where counter space is limited, Orbit is the ideal presentation scanner for retail, convenience, liquor and specialty stores. In addition, Orbit’s unique, contoured sh ...

  • Honeywell Metrologic MS7120 Orbit - page 6

    2 S CANNER A ND A CCESSORIES B ASI C K IT Part # Description MS 7120 Orbit ® Presentation Laser Scanner 00-02407 MetroSelect ® Programming Guide 00-02408 MS 7120 Installation and User’s Guide* * Avai labl e on th e Metro logic website - www.metro logic .com O PTIONAL A CCESSORIES Part # Description AC to DC Pow er Transformer- Regulated 5.2VD C ...

  • Honeywell Metrologic MS7120 Orbit - page 7

    3 S CANNER AND A CCESSORIES O PTIONA L A CCESSORIES Part # Description MVC** Metrologic Voltage Converter Cable +12VDC to +5.2VDC or -12VDC to +5.2VDC MX009-2** MX009 USB Converter Cable ** Contact a Metrologic customer service representative for additional information on the MVC and MX009 cable series and the host connections available. 45-45619 C ...

  • Honeywell Metrologic MS7120 Orbit - page 8

    4 I NST A LLATION FOR RS232, OCIA AND IBM 46XX I NTERFACES 1. Turn of f the host system . 2. Plug the male 10- pin RJ45 end of the PowerLink c able into the 10-pin jack on the MS7120. 3. Connect the 9 pin fem ale end of the PowerLink c able to the host device. Note: Sk ip to #6 if rece iving power from the host system. 4. Plug the power supply’ s ...

  • Honeywell Metrologic MS7120 Orbit - page 9

    5 I NSTALLA TION FOR K EYBOA RD W EDGE I NTERFACE 1. Turn of f the PC/Host. 2. Connect the m ale 10-pin RJ45 end of the PowerLink c able to the jack on the MS7120. 3. Connect the L-shaped plug of the power supply into the pow er jack on the PowerLink c able. 4. Make s ure the AC input requirem ents of the power supply matches the AC outlet. Plug th ...

  • Honeywell Metrologic MS7120 Orbit - page 10

    6 I N S T A LL A T I ON FO R S T A N D A LONE K EYB O A RD I N T ERF A CE 1. Turn of f the host system . 2. Plug the male 10- pin RJ45 end of the PowerLink c able into the 10-pin jack on the MS7120. 3. Connect the PowerLink c able to the keyboard port on the host system. 4. Plug the power supply’ s L-shaped plug into the power jack on the PowerLi ...

  • Honeywell Metrologic MS7120 Orbit - page 11

    7 I NSTA LLA TION N OTES FOR USB I NT ERFA CE Metrologic’s MX 009 USB cable is a device that conver ts serial RS232 form atted data to either USB Keyboard or USB Point-of Sale com munica tion protocol. Please ref er to the MX009 USB Converter Cable Programming Guide ( MLPN 00-02574A) s upplied wi th y our MX009 cable f or detailed installation an ...

  • Honeywell Metrologic MS7120 Orbit - page 12

    8 S CANNER P ART S Red LED On a succ essful r ead of a bar code, the red LED will turn ON . After c omm unication to the host is c omplete, the red LED will turn OFF . Refer to Visual Indicator s and Audible Indicators for additional inform ation. Green LED During norm al operation, the green LED is ON . T his indicates that the laser is on and the ...

  • Honeywell Metrologic MS7120 Orbit - page 13

    9 A UDIBLE I NDICATORS When the MS7120 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect ® Programming Guide ( MLPN 00-02407B) or the MetroSet2 help files. ...

  • Honeywell Metrologic MS7120 Orbit - page 14

    10 V ISUAL I NDICA T ORS There is a red LED and a green LED on the head of the MS7120. W hen the scanner is on, the flashing or cons tant illumination of the LEDs indicates the status of the current s can and the scanner. No Red or Green LE D The LEDs will not be illuminated if the sc anner is not receiving power from the host or transf orm er. Ste ...

  • Honeywell Metrologic MS7120 Orbit - page 15

    11 F A ILURE M ODES Flashing Gree n and One Razzber ry Tone This indicates the scanner has experienced a laser subsystem f ailure. Return the unit for r epair at an authorized service center . Flashing R ed and Green and T w o Ra zz be rr y Tones This indicates the scanner has experienced a m otor failure. Retur n the unit for repair at an author i ...

  • Honeywell Metrologic MS7120 Orbit - page 16

    12 L ABELS Each scanner has three labels on the bottom of the unit. These labels contain information such as; the model number, date of manufacture, serial number, laser class and caution statements. The following illustrations show the location and content of the three labels. M AINTENANCE Smudges and dirt can interfere with the proper scanning of ...

  • Honeywell Metrologic MS7120 Orbit - page 17

    13 S CAN V OLUME S PECIFICATIONS Specific ations based on 100% UPC Bar Codes. Optimal Low Density (Default) Optimal Hi gh Density 190mm 60mm 100mm Scan Area 215mm 105mm Scan Area 60mm ...

  • Honeywell Metrologic MS7120 Orbit - page 18

    14 S CAN V OLUME S PECIFICATIONS (C ONT .) Specific ations based on 100% UPC Bar Codes. Close Normal 95mm 175mm Scan Area 60mm Scan Area 190mm 60mm 100mm ...

  • Honeywell Metrologic MS7120 Orbit - page 19

    15 S CAN V OLUME S PECIFICATIONS (C ONT .) Specific ations based on 100% UPC Bar Codes. Far 215mm Scan Area 75mm 75mm 105mm ...

  • Honeywell Metrologic MS7120 Orbit - page 20

    16 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH O p tim a l Lo w D e n s ity ( D e f a u lt) Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width ABCDE F GH J K mm .13 .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5.2 5.7 6.3 6.8 7.5 9 10 13 21 26 0 0 0 0 0 0 B & & ...

  • Honeywell Metrologic MS7120 Orbit - page 21

    17 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH Optimal Hi gh Density Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width ABCDE F GH J K mm .13 .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5.2 5.7 6.3 6.8 7.5 9 10 13 21 26 B D & 0 0 0 & ...

  • Honeywell Metrologic MS7120 Orbit - page 22

    18 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH Close Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width BCDE F G H J K mm .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5 . 7 6 . 3 6 . 8 7 . 5 9 1 01 32 12 6 0 D ...

  • Honeywell Metrologic MS7120 Orbit - page 23

    19 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH Normal Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width ABCDE F GH J K mm .13 .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5.2 5.7 6.3 6.8 7.5 9 10 13 21 26 0 0 0 0 D & & ...

  • Honeywell Metrologic MS7120 Orbit - page 24

    20 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH Far Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width ABCDE F GH J K mm .13 .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5.2 5.7 6.3 6.8 7.5 9 10 13 21 26 0 00 0 D & ...

  • Honeywell Metrologic MS7120 Orbit - page 25

    21 I NSTALLING THE O PTIONAL W ALL /C OUNTER M OUNT Kit #45-45619 contains: a. Locking Plate [ MLPN 50-50302] ............................ Qty. 1 b. Base Cover [ MLPN 50-50301] ............................ Qty. 1 c. Wood Screw, #7 x 1.00” [ MLPN 18-18013] ............................ Qty. 3 d. Flathead Screw, M3 x 8 mm [ MLPN 18-18004] .......... ...

  • Honeywell Metrologic MS7120 Orbit - page 26

    22 T ROUBLESHOOTING G UIDE The f ollowing guide is for ref erence purposes only. Contact a Metrologic representative at 1- 800-ID-METRO or 1-800-436-3876 to preser ve the limited warr anty term s on page 39. All Interfaces MS7120 Series Troubleshooting Guide SYMPTOMS POSSIBLE CAUSE(S) SOLUTION No LEDs, beep or motor spin No power is being supplied ...

  • Honeywell Metrologic MS7120 Orbit - page 27

    23 T ROUBLESHOOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit pow ers up, but does not scan and/or beep Beeper disabled. No tone selected Enable beeper. Select tone The unit pow ers up, but does not scan and/or beep Scanning a particular symbology that is not enabled UPC/EAN, Code 39, interleav ed 2 of 5, Code 93, Code 128 a ...

  • Honeywell Metrologic MS7120 Orbit - page 28

    24 T ROUBLESHOOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanner beeps at some bar codes and NOT for others of the same bar code symbology The print quality of the bar code is suspect Check print mode. The ty pe of printer could be the problem. Change print settings. For example change to econo mode or high speed Scanner beeps a ...

  • Honeywell Metrologic MS7120 Orbit - page 29

    25 T ROUBLESHOOTING G UIDE (C ONTINUED ) Keyboard Wedge Only SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit scans the bar code but there is no data Configuration is not correct Make sure the scanner is configured for the appropriate mode. Check internal jumper The unit scans but the data is not correct Configuration is not correct Make sure that the ...

  • Honeywell Metrologic MS7120 Orbit - page 30

    26 T ROUBLESHOOTING G UIDE ( CONTINUED ) R S -232 O nly SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Power-up OK and scans OK but does not communicate properly to the host Com port at the host is not working or configured properly Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for ...

  • Honeywell Metrologic MS7120 Orbit - page 31

    27 RS-232 D EMONSTRA T ION P ROGRAM If an RS-232 scanner is not communicating w ith your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. T his program is for demonstration purposes only. It is only intended to prove that cabling is correct, the com port is w orking, and the scanner ...

  • Honeywell Metrologic MS7120 Orbit - page 32

    28 A PPLICATIONS AND P ROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S ) 7120 00 Laser Emulation RS-232 Transmit/Receive 7120 9 OCIA and RS-232 Transmit/Receive (Full RS232 Configurable) 7120 11 IBM 46XX and Full RS-232C 712 ...

  • Honeywell Metrologic MS7120 Orbit - page 33

    29 D ESIGN S PECIFICATIONS MS7120 S PECIFICAT IONS O PE RATI ONAL Light Source: VLD 640-660 nm Depth of Field: 0 mm to 216 mm (0" to 8.5") for 0.33 mm (13 mil) bar codes Scan Speed: 1067 scans/second Scan Pattern: 5 fields of 4 par allel lines (omnidirectional) Scan Lines: 20 Min Bar Width: 0.13 mm (5.2 mil) Decode Capability: Autodiscrim ...

  • Honeywell Metrologic MS7120 Orbit - page 34

    30 D ESIGN S PECIFICATIONS MS7120 S PECIFICAT IONS E LECTRICA L Input Voltage: 5.2VDC ± 0.25V Power: 1.0 W typical Operating Current: 200 mA typical, 250 mA typical for IBM models DC Transformers: Class II; 5.2VDC@ 650 mA Laser Class: CDRH: Class IIa; EN 60825-1:1994/A11:1996 Class 1 EMC: FCC, ICES-003 & EN 55022 Class B E NVIRONMENTA L Operat ...

  • Honeywell Metrologic MS7120 Orbit - page 35

    31 D EFA ULT S ETTINGS Many functions of the scanner c an be "program med" - that is, enabled or disabled. T he scanner is shipped f rom the factory programm ed to a set of def ault conditions. The def ault parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an aster isk is not in the default colum n th ...

  • Honeywell Metrologic MS7120 Orbit - page 36

    32 D EFA ULT S ETTINGS Paramet er Default OCIA RS-232* Light Pen IBM 46XX KBW Laser Emulat ion DTS/NIXDORF * ü NCR F ü NCR S ü Poll L ight Pe n Source ü Beeper Tone Normal üüüü ü ü Beep/Transmit Sequen ce Before Transmit üüüü ü ü Communic atio n Time out None üüüü ü ü Razzb erry To ne on T imeout üüüü ü ü Three Beeps on ...

  • Honeywell Metrologic MS7120 Orbit - page 37

    33 D EFA ULT S ETTINGS Paramet er Default OCIA RS-232* Light Pen IBM 46XX KBW Laser Emulat ion Convert EAN-8 to EAN-13 üü ü ü Transmit UPC-A Number System * üüüü ü ü Transmit UPC-A Manufa cturer ID# * üüüü ü ü Transmit UPC-A Item ID# * üüüü ü ü Transm it Codabar Start/Stop Char acters üü ü ü CLSI Editin g (Enable) üü ü ...

  • Honeywell Metrologic MS7120 Orbit - page 38

    34 D EFA ULT S ETTINGS Paramet er Default OCIA RS-232* Light Pen IBM 46XX KBW Laser Emulat ion Carria ge Ret urn * üü Line Feed - di sabled by default in KB W * üü Tab Pr efi x üü Tab Suffix üü "DE" Disable Command ü "FL" Laser E nable Command ü DTR Hands hakin g Support ü RTS/CT S Handshaking ü Character RTS/CTS * ? ...

  • Honeywell Metrologic MS7120 Orbit - page 39

    35 D EFA ULT S ETTINGS Paramet er De fault OCIA RS-232* Light Pen IBM 46XX KBW Laser Emulat ion Coupon Code 128 üü as code 39 üü as code 39 Progr ammable Code Lengths 7 avail. üü ü üü ü Progr ammable Pr efix Character s 10 avail. ü Suffix Ch aracters ü Prefi xes for i ndiv idual Code Ty pe s Editing üü ü üü ü Inter Scan-Code Delay ...

  • Honeywell Metrologic MS7120 Orbit - page 40

    36 1 10 S CANNER A ND C AB LE T ERMINATIONS Scanner Pinout Connections The MS7120 s canner interfac es terminate to a 10-pin m odular jack . The serial # label indicates the interf ace enabled when the scanner is shipped from the factor y . Som e units have internal jum pers that c an be moved to enable a diff erent electrical interf ace. Current c ...

  • Honeywell Metrologic MS7120 Orbit - page 41

    37 S CANNER AND C ABLE T ERMINATIONS MS7120-11 IBM 46XX/RS-232 Pin Function 1 Ground 2 RS-232 Transmit Output 3 RS-232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 IBM 46XX transmit 8 IBM 46XX Receive 9+ 5 V D C 10 Shield Ground Options listed are program/cable selections Cable Connector configurations PowerLink Cable MLPN 54-54xxx* or 53-5 ...

  • Honeywell Metrologic MS7120 Orbit - page 42

    38 S CANNER A ND C AB LE T ERMINATIONS Cable Connector Configur ation The PowerLink cable is term inated with a 5-pin DIN fem ale connector on one end, and a 6-pin m ini DIN male on the other. Metrologic will supply an adapter cable with a 5-pin DIN male c onnector on one end and a 6-pin m ini DIN female c onnector on the other. According to the te ...

  • Honeywell Metrologic MS7120 Orbit - page 43

    39 L IMITED W A RRANTY The MS7120 Orbit © scanners are manufactured by Metrologic at its Blackw ood, New Jersey, U.S.A. facility . The MS7120 scanners have a t wo (2) y ear limited warranty f rom the dat e of manufacture. Metrologic w arrants and represents that all MS7120 scanners are free of all defects in material, w orkmanship and design, and ...

  • Honeywell Metrologic MS7120 Orbit - page 44

    40 N OTICE S Notices This equipment has been tested and found t o comply with the limit s for a Class B digital device, pursuant to part 15 of the FCC rules. These limit s are designed to provide reasonable protection against harmful interference in a residential inst allation. This equipment generates, uses and can radiat e radio frequency energy ...

  • Honeywell Metrologic MS7120 Orbit - page 45

    41 N OTICE S Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu w arten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. ...

  • Honeywell Metrologic MS7120 Orbit - page 46

    42 N OTICE S Die nachfolgende Mitteilung gilt nur für Modell Nr. MS7120-11 Zur Klassifizierung gemäß Klasse B nach FCC T eil 15, ICES-003 und EN55022, befestigen Sie den vorliegenden Ferritkern an dem mitgelieferte Pow erLink Kabel Ihres MS7120-11 Barcode Scanners. Ferritkern Installation: 1. Entfernen Sie den vorliegenden Ferritkern aus der Sch ...

  • Honeywell Metrologic MS7120 Orbit - page 47

    43 N OTICE S Nota (exclusivamente para los modelos de la ser ie MS7120-11) De acuerdo con las normativas FCC apartado 15, IC ES-003 y EN55022 para la Clase B, el obturador de ferrita del PowerLink que se suministra con el modelo de lector de códigos de barras MS7120-11. Instalación del obturador de ferrita 1. Quitar el envoltorio protector del ob ...

  • Honeywell Metrologic MS7120 Orbit - page 48

    44 P AT EN T S This M ETROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 4,960,985; 5,081,342; 5,216,232; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,557,093; 5,591,953; 5,616,908; 5,627,359; 5,637,852; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,811,780; 5 ...

  • Honeywell Metrologic MS7120 Orbit - page 49

    45 I NDEX A access ories .......................... 2, 3 adapter ....................... 2, 3, 5, 38 application .............................. 27 audible ..................................... 9 authorized service center ....... 11 autodiscrim inates ................... 29 B bar code .......... 1, 3, 8-10, 12-20, 23-25, 27, 29, 41 beep ....... 4, 9 ...

  • Honeywell Metrologic MS7120 Orbit - page 50

    46 I NDEX N norm al depth of field .............. 35 notices ................. 40, 41, 42, 43 O OCIA .............. 1-4, 28, 29, 31-36 omnidir ectional................... 1, 29 operating current .................... 30 operating tem perature ........... 30 operation ...... 1, 5, 6, 8, 9, 29, 40 operational ......................... 3, 29 output win ...

  • Honeywell Metrologic MS7120 Orbit - page 51

    ...

  • Honeywell Metrologic MS7120 Orbit - page 52

    October 2005 Printed in USA 00 - 02408 D ...

Fabricant Honeywell Catégorie Barcode readers

Les documents que nous recevons du fabricant de l'appareilHoneywell Metrologic MS7120 Orbit peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Honeywell
- manuels d’utilisations Metrologic MS7120 Orbit
- fiches produit Honeywell
- dépliants
- ou étiquettes-énergie Honeywell Metrologic MS7120 Orbit
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Honeywell Metrologic MS7120 Orbit.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Honeywell Metrologic MS7120 Orbit, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Honeywell Metrologic MS7120 Orbit. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Honeywell Metrologic MS7120 Orbit.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Honeywell Metrologic MS7120 Orbit, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Honeywell Metrologic MS7120 Orbit par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Honeywell Metrologic MS7120 Orbit.

Le manuel d’utilisation complet Honeywell, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Honeywell Metrologic MS7120 Orbit - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Honeywell Metrologic MS7120 Orbit, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHoneywell Metrologic MS7120 Orbit qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Honeywell Metrologic MS7120 Orbit - qui devraient nous aider dans les premières étapes lors de l'utilisation Honeywell Metrologic MS7120 Orbit
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Honeywell Metrologic MS7120 Orbit
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Honeywell Metrologic MS7120 Orbit dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Honeywell Metrologic MS7120 Orbit?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Honeywell Metrologic MS7120 Orbit, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Honeywell Metrologic MS7120 Orbit il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image