    Save this manual for future reference. UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any o ...

  • Vanguard Managed Solutions PRVYS18PWA - page 2

    2 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at ...

  • Vanguard Managed Solutions PRVYS18PWA - page 3

    3 104343 OWNER’S MANUAL LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, ...

  • Vanguard Managed Solutions PRVYS18PWA - page 4

    4 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® AIR FOR COMBUSTION AND VENTILA TION Unusually Tight Construction The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight ...

  • Vanguard Managed Solutions PRVYS18PWA - page 5

    5 104343 OWNER’S MANUAL DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the ro ...

  • Vanguard Managed Solutions PRVYS18PWA - page 6

    6 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ...

  • Vanguard Managed Solutions PRVYS18PWA - page 7

    7 104343 OWNER’S MANUAL NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Op- eration, page 10. Log Sizing Requirement ...

  • Vanguard Managed Solutions PRVYS18PWA - page 8

    8 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued Minimum Non-combustible Material Clearances If Not Using Mantel You must have non-combustible material(s) above the fireplace opening. Non-combus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you mu ...

  • Vanguard Managed Solutions PRVYS18PWA - page 9

    9 104343 OWNER’S MANUAL Figure 7 - Minimum Mantel Clearances When Using Hood Minimum Non- Combustible Material 8" Min. 12" 15" 18" All minimum distances are in inches Log Sets All Models 20" 2 1 /2 " 6" 8" 10" 12" Distances to Underside of Mantel Hood (GA6050, GA6052) Top of Fireplace Opening Unde ...

  • Vanguard Managed Solutions PRVYS18PWA - page 10

    10 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of non combustible material. If your heater is a manually c ...

  • Vanguard Managed Solutions PRVYS18PWA - page 11

    11 104343 OWNER’S MANUAL Masonry Screw Figure 12 - Attaching Base Assembly to Fireplace Floor Bracket with Screw Holes Standard Oak Log Chassis Golden Oak and Birch Model Chassis Masonry Screw Bracket with Screw Holes INST ALLA TION Continued Heater Gas Regulator Flexible Gas Hose (if allowed by local codes) Figure 11 - Attaching Flexible Gas Hos ...

  • Vanguard Managed Solutions PRVYS18PWA - page 12

    12 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued Tee Joint Pipe Nipple Cap 3" Minimum Sediment Trap Gas Regulator From External Regulator (11" W.C.** to 14" W.C. Pressure) A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap* Approved Flexible Gas Hose (if allowed by local ...

  • Vanguard Managed Solutions PRVYS18PWA - page 13

    13 104343 OWNER’S MANUAL ON POSITION OFF POSITION INST ALLA TION Continued Figure 15 - Manual Shutoff Valve Open Closed Manual Shutoff Valve Figure 16 - Checking Gas Joints Control Valve Location Propane Supply Tank Manual Shutoff Valve Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its ind ...

  • Vanguard Managed Solutions PRVYS18PWA - page 14

    14 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. INSTALLING LOGS For Vintage Oak Model Each log is marked with a ...

  • Vanguard Managed Solutions PRVYS18PWA - page 15

    15 104343 OWNER’S MANUAL 1. STOP! Read the safety inf ormation above. 2. Make sur e manual shutoff valve is fully open. 3. Press in and tur n control knob clock- wise Clockwise to the OFF position. Figure 23 - Pilot OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explos ...

  • Vanguard Managed Solutions PRVYS18PWA - page 16

    16 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® OPERA TING HEA TER Continued TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Press in and turn control knob clock- wise Clockwise to the HIGH position. 2 . T urn the control knob clockwise Clockwise to the PILOT position. 3. Press in control knob and turn clock- wise Clockwis ...

  • Vanguard Managed Solutions PRVYS18PWA - page 17

    17 104343 OWNER’S MANUAL INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 26 shows a correct pilot flame pat- tern. Figure 27 shows an incorrect pilot flame pattern. ( Note: Appearance of pilot assembly may vary by model.) The incor- rect pilot flame is not touching the thermo- couple. This ...

  • Vanguard Managed Solutions PRVYS18PWA - page 18

    18 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ...

  • Vanguard Managed Solutions PRVYS18PWA - page 19

    19 104343 OWNER’S MANUAL TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Moisture/condensation noticed on windows Dark residue on logs or inside or f ...

  • Vanguard Managed Solutions PRVYS18PWA - page 20

    20 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supp ...

  • Vanguard Managed Solutions PRVYS18PWA - page 21

    21 104343 OWNER’S MANUAL OPTIONAL POSITIONING OF THERMOST A T SENSING BULB FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb. The thermostat sensing bulb is locate ...

  • Vanguard Managed Solutions PRVYS18PWA - page 22

    22 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SPECIFICA TIONS Vintage Oak Vintage Oak Golden Oak and Birch 18" Variable 24" Variable 18" Variable Manually Manually Manually Controlled Controlled Controlled Btu (Variable) 16,000/27,000 16,000/31,500 16,000/30,000 Type Gas Propane Only Propane Only Propane Only ...

  • Vanguard Managed Solutions PRVYS18PWA - page 23

    23 104343 OWNER’S MANUAL Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190. When cal ...

  • Vanguard Managed Solutions PRVYS18PWA - page 24

    24 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX™ VINTAGE OAK MODELS VYS18P AND VYS24P 4 1 2 3 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 22 18 13 19 17 20 18 20-1 20-2 23 20-1 20-2 ODS Pilot ...

  • Vanguard Managed Solutions PRVYS18PWA - page 25

    25 104343 OWNER’S MANUAL P AR TS LIST VYS18P VYS24P This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY PART NUMBER FOR NO. VYS18P VYS24P DESCRIPTION QTY. 1 102968-01 102968-02 Back Log (#1) 1 2 102969-01 102969-02 Front Log (#2) 1 3 1 ...

  • Vanguard Managed Solutions PRVYS18PWA - page 26

    26 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX™ GOLDEN OAK AND BIRCH LOG MODELS VYD18P, VYBD18P, VYD24P, VYBD24P,VYD30P, VYBD30P, AND VYD36P 4 20 10 11 12 20 7 20 20 5 6 9 8 15 14 16 18 2 17 13 18 3 19 17 1A 1B *Note: The Golden Oak Log (104254-01) for the VYD36P model differs sligh ...

  • Vanguard Managed Solutions PRVYS18PWA - page 27

    27 104343 OWNER’S MANUAL P AR TS LIST VYD18P, VYBD18P VYD24P, VYBD24P VYD30P, VYBD30P VYD36P This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY PART NUMBER FOR NO. VYD18P VYBD18P VYD24P VYBD24P VYD30P VYBD30P VYD36P DESCRIPTION QTY. 1 ...

  • Vanguard Managed Solutions PRVYS18PWA - page 28

    28 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ILLUSTRA TED PA R T S BREAKDOWN THERMOSTATICALLY- CONTROLLED MODELS VYD18PT VYD24PT VYD30PT 12 1 2 18 16 17 20 10 9 5 11 4 7 6 19 8 21 13 19 14 19 19 3 15 17 19 ...

  • Vanguard Managed Solutions PRVYS18PWA - page 29

    29 104343 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. P AR TS LIST VYD18PT VYD24PT VYD30PT KEY VYD18PT VYD24PT VYD30PT NO. PART NUMBER PART NUMBER PART NUMBER DESCRIPTION QTY. 1 103517-01 102785-01 103519-01 Log Set, ...

  • Vanguard Managed Solutions PRVYS18PWA - page 30

    30 104343 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual. MAN ...

  • Vanguard Managed Solutions PRVYS18PWA - page 31

    31 104343 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Vanguard Managed Solutions PRVYS18PWA - page 32

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased LIMITED ...

Fabricant Vanguard Managed Solutions Catégorie Fan

Les documents que nous recevons du fabricant de l'appareilVanguard Managed Solutions PRVYS18PWA peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vanguard Managed Solutions
- manuels d’utilisations PRVYS18PWA
- fiches produit Vanguard Managed Solutions
- dépliants
- ou étiquettes-énergie Vanguard Managed Solutions PRVYS18PWA
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vanguard Managed Solutions PRVYS18PWA.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vanguard Managed Solutions PRVYS18PWA, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vanguard Managed Solutions PRVYS18PWA. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vanguard Managed Solutions PRVYS18PWA.

Manuel d’utilisation complet de l’appareil Vanguard Managed Solutions PRVYS18PWA, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vanguard Managed Solutions PRVYS18PWA par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vanguard Managed Solutions PRVYS18PWA.

Le manuel d’utilisation complet Vanguard Managed Solutions, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vanguard Managed Solutions PRVYS18PWA - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vanguard Managed Solutions PRVYS18PWA, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVanguard Managed Solutions PRVYS18PWA qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vanguard Managed Solutions PRVYS18PWA - qui devraient nous aider dans les premières étapes lors de l'utilisation Vanguard Managed Solutions PRVYS18PWA
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vanguard Managed Solutions PRVYS18PWA
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vanguard Managed Solutions PRVYS18PWA dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vanguard Managed Solutions PRVYS18PWA?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vanguard Managed Solutions PRVYS18PWA, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vanguard Managed Solutions PRVYS18PWA il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)