Manuel d’utilisation Vermont Casting 2310

28 pages 0.91 mb
Télécharger

Aller à la page of 28

Summary
  • Vermont Casting 2310 - page 1

    0898 Vigilant Cover 8/6/01 djt V igilant II Coal Stove Model #2310 Homeowner ’ s Installation and Operating Instructions For Use in North America Do Not Discard This Manual: Retain for Future Use SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAINT AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, F ...

  • Vermont Casting 2310 - page 2

    2 V er mont Castings V igilant 2000898 W elcome Congratulations on your choice of a V ermont Castings Vigilant II Coal Stove. With this purchase, you have made a commitment to make the hearth a place of warmth, beauty and comfort in your home. At V ermont Castings, we share that joy and appreciation for the hearth, and we show it in all our cast-ir ...

  • Vermont Casting 2310 - page 3

    3 V er mont Castings V igilant 2000898 Specifications Vigilant II Coal Stove Model #2310 Coal type ................................ Anthracite or bituminous Coal size ....................................................... Pea or nut Maximum heat output .......................... 50,000 Btu’ s/hr* Maximum area heated ............................ ...

  • Vermont Casting 2310 - page 4

    4 V er mont Castings V igilant 2000898 Installation Codes and Listings Conforming to local building codes will be an important part of your planning. Local authorities make the final decision on whether or not an installation will be ap- proved. They need to know that your installation is safe and meets local codes. The metal label permanently att ...

  • Vermont Casting 2310 - page 5

    5 V er mont Castings V igilant 2000898 Weak draft situations are characterized by smoking and odor problems in the house, low heat output, and difficulty maintaining a fire, especially at low thermostat settings. The reverse situation, overdraft, is rare, but can be recognized by short burn time, poor response when trying to slow down the fire, ...

  • Vermont Casting 2310 - page 6

    6 V er mont Castings V igilant 2000898 A B C E D F G H I J H ST562 Chimney hazards 12/14/00 djt ST562 Fig. 6 Existing chimney . D. Blockage within flue; remove. E. Improper clearance between chimney and com- bustible materials. Generally , a clearance of 2” (50 mm.) is required to all combustible walls and framing members; check local code ...

  • Vermont Casting 2310 - page 7

    7 V er mont Castings V igilant 2000898 Clearances Y our stove and chimney connector will radiate energy in all directions when in operation. An important part of planning a safe installation is to be sure combustible materials near your stove do not overheat due to inad- equate clearance. Clearance is the distance between your stove (or chim- ney c ...

  • Vermont Casting 2310 - page 8

    8 V er mont Castings V igilant 2000898 If the Vigilant is installed in a corner (corner installation) and no shields are used, the corners of the stove must be at least 16” (410 mm) from nearby walls. (Fig. 6) Measure these distances from the edge of the top plate of the stove nearest the wall to the combustible part of the wall. Unshielded singl ...

  • Vermont Casting 2310 - page 9

    9 V er mont Castings V igilant 2000898 VIGILANT 24"  (610mm) Max. ST687 chimney connector 8/7/01 djt Prefabricated Chimney Single-wall Chimney Connector Chimney Connector Heat Shield Bottom Heat Shield ST687 Fig. 9 Chimney connector heat shields may be used to re- duce clearances when single-wall connectors are used. Clearances Wit ...

  • Vermont Casting 2310 - page 10

    10 V er mont Castings V igilant 2000898 V igilant II Clearance Chart Unprotected Surfaces Side Rear Corners Side Rear Corners Stove in Corner Stove Installed Par- allel to W all Stove in Corner Stove Installed Par- allel to W all Stove Clearance Protected Surfaces Chimney Connector Clearance Single-wall connector No heat shields Single-wall connect ...

  • Vermont Casting 2310 - page 11

    1 1 V er mont Castings V igilant 2000898 Floor Protection Freestanding Installations A tremendous amount of heat radiates from the bottom plate of a Vigilant Coal Stove, and the floor beneath re- quires special protection. A Vigilant Coal Stove Bottom Heat Shield (be sure to install the included shield insert when the shorter 7 ⁷⁄₈ (197 mm) ...

  • Vermont Casting 2310 - page 12

    12 V er mont Castings V igilant 2000898 An unprotected mantel must have a minimum clear- ance of 36”, measured from the stove’s top plate; with a ventilated shield the clearance may safely be reduced to 18”. Unprotected top trim must be a minimum of 36” from the stove’s top surface; with a ventilated trim shield the clearance may be safel ...

  • Vermont Casting 2310 - page 13

    13 V er mont Castings V igilant 2000898 Horizontal runs of chimney connectors should slope upward 1/4” per foot going from the stove toward the chimney . The recommended maximum length of a horizontal run is 3 feet. The total length of chimney connector should be no longer than 8 feet to prevent the cooling of flue gases. In cathedral ceiling in ...

  • Vermont Casting 2310 - page 14

    14 V er mont Castings V igilant 2000898 Securing the Connector to a Prefabricated Chimney Follow the installation instructions of the chimney manufacturer exactly as you install the chimney . The manufacturer of the chimney will supply the accesso- ries to support the chimney , either from the roof of the house or at the ceiling of the room where t ...

  • Vermont Casting 2310 - page 15

    15 V er mont Castings V igilant 2000898 connector enters the chimney . Follow all the guidelines for installing a chimney connector into a freestanding masonry chimney , and watch these additional points: ST695 Vigilant above fireplace 8/8/01 VIGILANT� Thimble Sleeve Mantel Bottom Heat Shield Damper - closed and locked ST695 Fig. 20 In this in ...

  • Vermont Casting 2310 - page 16

    16 V er mont Castings V igilant 2000898 Operation The Vigilant Controls The Thermostat Lever Adjust the thermostat lever to control the heat level. Move the thermostat lever to the left to make the fire burn hotter . Move it to the right for less heat. The thermostat regulates the heat level when the stove is operating by controlling the amount of ...

  • Vermont Casting 2310 - page 17

    17 V er mont Castings V igilant 2000898 3. Continue building up the fire until there is a thick bed of hot embers on the grates. IMPORT ANT : Don’t hurry this part of the burn. Inad- equate preheating of the chimney system is the most common cause of poor coal stove performance. NOTE: The cast iron plates in your V igilant will “sea- son” as ...

  • Vermont Casting 2310 - page 18

    18 V er mont Castings V igilant 2000898 Reloading the Stove Put on a small layer of fresh coal and allow it to catch before clearing the grates of ash. Once the new coal is ignited, shake the grates with full, steady strokes of the shaker handle. Stop shaking when red coals cover the ashpan or when you feel resistance. Using the slicer , clear ash ...

  • Vermont Casting 2310 - page 19

    19 V er mont Castings V igilant 2000898 Maintenance The fire must be out and the stove no longer hot before you work on the stove. We suggest you wear gloves and safety goggles when working on your stove. Cleaning Cast Iron An occasional dusting with a dry rag is usually all that is necessary to keep your Vigilant looking new . From time to time, ...

  • Vermont Casting 2310 - page 20

    20 V er mont Castings V igilant 2000898 • Select the appropriate gasket. Y our V ermont Cast- ings Authorized Dealer carries a complete line of gaskets. Cut to the recommended length plus a 1” - 2” excess. • Place an unbroken 1/8” bead of gasket cement in the channel or groove. • Starting at one end, press the gasket into the chan- nel. ...

  • Vermont Casting 2310 - page 21

    21 V er mont Castings V igilant 2000898 Because access to the areas behind the side plates and lower fireback is possible through the three clean- out access covers, it usually will not be necessary to remove any other interior parts. Contact your local V ermont Castings Authorized Dealer for instructions if it is necessary to remove the remaining ...

  • Vermont Casting 2310 - page 22

    22 V er mont Castings V igilant 2000898 Adjust the Chain Length 1. Make the initial chain adjustment when the stove is cold. With the lever pointing straight up, connect the ball chain to the air intake shutter so the shutter is half open. This setting will work well for most instal- lations. 2. Replace the back heat shield if there was one in- sta ...

  • Vermont Casting 2310 - page 23

    23 V er mont Castings V igilant 2000898 The Maintenance Guidelines given below will help you develop a schedule that works for you. Once you have developed a maintenance schedule, stick to it. Daily: • Ashes should be removed before the ashes reach the top of the ashpan. Check at least once a day . A build up of ashes under the grates will not on ...

  • Vermont Casting 2310 - page 24

    24 V er mont Castings V igilant 2000898 1 48 51 54 53 56 55 47 21 45 44 50 41 40 15 49 20 58 18 17 46 12 1 1 16 13 14 19 10 9 15 2 52 51 3 4 5 6 7 8 22 32 31 62 61 33 34 30 57 59 36 37 38 43 42 39 29 35 23 26 25 28 27 29 30 24 0898 Vigilant parts 8/02 djt 0898 V igilant Coal II Model 2310 Item Description Part Number Item Description Part Number CF ...

  • Vermont Casting 2310 - page 25

    25 V er mont Castings V igilant 2000898 V igilant Coal II Model 2310 (continued) Item Description Part Number Item Description Part Number 13. T riangle Firebrick 1600906 14. Right Inner Side 1305002 15. T ie Rod (1) 1601629 T ie Rod Set (4) 5007497 16. Rear Grate Support 130501 1 17. High Grate Bar 1305040 18. Low Grate Bar 1305039 19. Front Grate ...

  • Vermont Casting 2310 - page 26

    26 V er mont Castings V igilant 2000898 ...

  • Vermont Casting 2310 - page 27

    27 V er mont Castings V igilant 2000898 Limited Three Y ear W arranty CFM Corporation warrants that this Vigilant II Coal Stove will be free of defects in material and work- manship for a period of three years from the date you receive it, except that the thermostat assembly , coal grates, handles, glass door panels, cement, and gasketing shall be ...

  • Vermont Casting 2310 - page 28

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation ...

Fabricant Vermont Casting Catégorie Stove

Les documents que nous recevons du fabricant de l'appareilVermont Casting 2310 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vermont Casting
- manuels d’utilisations 2310
- fiches produit Vermont Casting
- dépliants
- ou étiquettes-énergie Vermont Casting 2310
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vermont Casting 2310.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vermont Casting 2310, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vermont Casting 2310. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vermont Casting 2310.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vermont Casting 2310, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vermont Casting 2310 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vermont Casting 2310.

Le manuel d’utilisation complet Vermont Casting, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vermont Casting 2310 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vermont Casting 2310, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVermont Casting 2310 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vermont Casting 2310 - qui devraient nous aider dans les premières étapes lors de l'utilisation Vermont Casting 2310
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vermont Casting 2310
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vermont Casting 2310 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vermont Casting 2310?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vermont Casting 2310, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vermont Casting 2310 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image