    Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL VENT -FREE INF ARED PROP ANE/LP GAS HEA TER Models: CGP16RA and CGP26D WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or ...

  • Desa CGP16RA - page 2

    2 101827 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ................................................................................... 4 Unpacking ...................... ...

  • Desa CGP16RA - page 3

    3 101827 SAFETY INFORMA TION Continued W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. Use only propane/LP gas. Do not convert heater to use different fuel type. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. 3. This heater shall not be installe ...

  • Desa CGP16RA - page 4

    4 101827 PRODUCT IDENTIFICA TION GRH/PV 006A COMFORT GLOW PLAQUE FRONT-NON THERMO Burners Heater Cabinet Front Panel Grill Guard PRODUCT FEA TURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is ...

  • Desa CGP16RA - page 5

    5 101827 Unconfined Space The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon- fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passag ...

  • Desa CGP16RA - page 6

    6 101827 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation ...

  • Desa CGP16RA - page 7

    7 101827 AIR FOR COMBUSTION AND VENTILA TION Continued Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 Continued WARNING ICON G001 W ARNING If the area in which the heater may be operated i ...

  • Desa CGP16RA - page 8

    8 101827 AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR (Continued) Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open t ...

  • Desa CGP16RA - page 9

    9 101827 IMPORT ANT : V ent-free heaters add moisture to the air . Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air f or Comb ustion and V entilation, pages 5 through 8. INST ALLING T O W ALL NOTICE A qualified service person must install heater. Follow a ...

  • Desa CGP16RA - page 10

    10 101827 Minimum From Sides Of Heater 36" 3" FLOOR CEILING Minimum Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material 8" Left Side Right Side Figure 4 - Mounting Clearances As Viewed From Front of Heater INST ALLING T O W ALL Continued CAUTION If you install the heater in a home garage • heater pilot and burne ...

  • Desa CGP16RA - page 11

    11 101827 INSTALLING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel. Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart ...

  • Desa CGP16RA - page 12

    12 101827 Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mount- ing bracket is level. 2. Mark screw locations on wall (see Figure 7). Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall. Figure 7 - ...

  • Desa CGP16RA - page 13

    13 101827 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. Figure 9 - Popping Open Anchor Wings For Thin Walls 5. Place mounting bracket onto wall. Line up last hole on each ...

  • Desa CGP16RA - page 14

    14 101827 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. CAUTION Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too ...

  • Desa CGP16RA - page 15

    15 101827 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Tee Joint Reducer Bushing to 1/8" NPT 1/8" NPT Plug Tap Test Gauge Connection * Tee Joint Pipe Nipple Cap Manual Shutoff Valve * 1/2" NPT Pipe Nipple Heater Cabinet Pressure Regulator Figure 13 - Gas Connection 3" Minimum G ...

  • Desa CGP16RA - page 16

    16 101827 3. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff v ...

  • Desa CGP16RA - page 17

    17 101827 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floo ...

  • Desa CGP16RA - page 18

    18 101827 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step. 5. Press in control knob. Note: You may be running this heater for the first time after hooking up to gas supply ...

  • Desa CGP16RA - page 19

    19 101827 TO SELECT HEA TING LEVEL 1. Slightly press in control knob and turn counterclockwise to the LOW, MEDIUM, or HIGH positions. IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position. CAUTION Do not try to adjust heating levels by using the manual shut- off valve. LOW OFF PILOT IGN MED ...

  • Desa CGP16RA - page 20

    20 101827 Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise to the PILOT position. MANUAL LIGHTING PROCEDURE 1. Follow steps 1 through 6 under Lighting Instructions , pages 17 ...

  • Desa CGP16RA - page 21

    21 101827 Bad Burner Pattern 5 Plaque GRH/OV 019A Figure 22 - Incorrect Burner Flame Pattern If burner flame pattern is incorrect, as shown in Figure 22 • turn heater off (see To Turn Off Gas to Appliance , page 20) • see Troubleshooting , pages 22 through 25 Figure 21 - Correct Burner Flame Pattern INSPECTING BURNER Continued BURNER FLAME PATT ...

  • Desa CGP16RA - page 22

    22 101827 CLEANING AND MAINTENANCE ODS/PILOT AND BURNER ORIFICE • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust. TROUBLE- SHOOTING ...

  • Desa CGP16RA - page 23

    23 101827 REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Press in control knob while turning to PILOT/IGN position 3. Continue holding down control knob. Repeat igniting operation until air is removed 4. Contact local propane/ LP gas company. 5. Clean ODS/pilot (see Cleaning and Mainte- nance , page 22) or replace ODS/pilot assembly 6 ...

  • Desa CGP16RA - page 24

    24 101827 OBSERVED PROBLEM Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during combustion Burner plaque(s) does not glow Slight smoke or odor during initial operation Heater produces a clicking/ticking noise just after burner is lit or shut off POSSIBLE CAUSE 1. Burner orifice(s) is clogged 2. Burn ...

  • Desa CGP16RA - page 25

    25 101827 TROUBLE- SHOOTING Continued If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, c ...

  • Desa CGP16RA - page 26

    26 101827 SPECIFICA TIONS CGP16RA CGP26D BTU (Variable) 6,000/11,000/16,000 6,000/16,000/26,000 Type Gas Propane/LP Only Propane/LP Only Ignition Piezo Piezo Pressure Regulator Setting 8" W.C. 8" W.C. Inlet Gas Pressure (in. of water) Maximum 14" 14" Minimum 11" 11" Dimensions, Inches (H x W x D) Heater 23.5 x 18.5 x 8 ...

  • Desa CGP16RA - page 27

    27 101827 MANUAL SHUTOFF VALVE - GA5010 Manual shutoff valve with 1/8" NPT tap. FLOOR MOUNTING STAND Model CGP16RA - GA4000B and GA4500 Model CGP26D - GA4010B and GA4510 For locating heater on the floor, away from a wall. Complete installation instructions included. ACCESSORIES Purchase these heater accessories from your local dealer. If they ...

  • Desa CGP16RA - page 28

    28 101827 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model CGP16RA 13-15 13-14 ODS/PILOT BURNER ASSEMBLY A B C 13-1 13-2 13-3 13-10 13-4 13-5 13-6 13-7 13-8 13-9 13-12 13-13 13-11 1 2 3 11 6 4 8 5 6 7 12 13 9 10 14 ...

  • Desa CGP16RA - page 29

    29 101827 P ARTS LIST Model CGP16RA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. PARTS AVAILABLE - NOT SHOWN KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-03 Front Panel 1 3 098238-06 Grill Guard 1 ...

  • Desa CGP16RA - page 30

    30 101827 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model CGP26D 13-15 13-14 ODS/PILOT BURNER ASSEMBLY E D C 13-1 13-2 13-3 13-9 13-4 13-5 13-7 13-6 13-8 13-10 13-12 13-13 13-11 B A 1 2 3 11 6 13 4 8 5 6 7 12 9 10 14 ...

  • Desa CGP16RA - page 31

    31 101827 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIST Model CGP26D PARTS AVAILABLE - NOT SHOWN KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-04 Front Panel 1 3 098238-07 Grill Guard 1 ...

  • Desa CGP16RA - page 32

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. 2701 Ind ...

Fabricant Desa Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilDesa CGP16RA peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Desa
- manuels d’utilisations CGP16RA
- fiches produit Desa
- dépliants
- ou étiquettes-énergie Desa CGP16RA
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Desa CGP16RA.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Desa CGP16RA, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Desa CGP16RA. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Desa CGP16RA.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Desa CGP16RA, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Desa CGP16RA par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Desa CGP16RA.

Le manuel d’utilisation complet Desa, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Desa CGP16RA - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Desa CGP16RA, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDesa CGP16RA qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Desa CGP16RA - qui devraient nous aider dans les premières étapes lors de l'utilisation Desa CGP16RA
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Desa CGP16RA
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Desa CGP16RA dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Desa CGP16RA?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Desa CGP16RA, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Desa CGP16RA il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)