    Victoreen® 948A-40 and 948A-50 Remote Alarm and Alarm/Meter Instruction Manual ...

  • Cardinal Gates 948A-40 - page 2

    (Blank Page) ...

  • Cardinal Gates 948A-40 - page 3

    i Contents Section 1: Introduction .................................................................................................................. .. 1-1 1.1 General De scription ........................................................................................................ ........................................ 1-1 1.2 Appli cation . ...

  • Cardinal Gates 948A-40 - page 4

    (Blank Page) ...

  • Cardinal Gates 948A-40 - page 5

    1-1 Secti o n 1 Introduction 1.1 General Description Remote Alarm and Alarm/Meter (948A-40 & 9 48A-50) The 948A-50 Remote Alarm/Meter contin uous ly indicates the level of radiation at the detector sit e and provides a visual and audible indication of a high radiation level o n an analog meter, light, and Sonalert. The meter of the Remote Alarm ...

  • Cardinal Gates 948A-40 - page 6

    1-2 1.4 Receiving Inspection Upon recei pt of the unit: 1. Inspect the carton(s) and contents for damage. If damage is evident, file a claim with the c arrier and notify Cardinal Health at 440.248.9300. 2. Remove the contents fr om the packing ma terial. 3. Verify that all items listed on the packing list have been received and are in good condi ti ...

  • Cardinal Gates 948A-40 - page 7

    1-3 Indicate d battery and ot her operation al tests must be performed prio r to each use to assure th at the instru ment is functioning properly. If applicable, failure to conduct pe riodic performance test s in accordance with ANSI N323-1978 (R1983) Radiat ion Protecti on Instrumentat ion Test and Cali bration, paragraphs 4.6 and 5.4, and to keep ...

  • Cardinal Gates 948A-40 - page 8

    (Blank page) ...

  • Cardinal Gates 948A-40 - page 9

    2-1 Secti o n 2 Installation 2.1 Installation Ensure all power is removed prior to installing the 948A- 40 or 948A-50 Remote Alarm, Alarm/Meter. Installation of the 948A-50 Remo te Alarm/Meter consist s of finding a suitable location for mounting, such as a wall or post, and providing an electrical interface. Both the 948A -40 and 948A-50 Remote Al ...

  • Cardinal Gates 948A-40 - page 10

    (Blank page) ...

  • Cardinal Gates 948A-40 - page 11

    3-1 Secti o n 3 Operation 3.1 Operation Since the operation and theory for the 948A-40 is ident ica l to the 948A-50 with th e exception that the 948A-40 has no meter, only the 948A-50 will be discussed. Once installation has been complete d, operation of the VICTOREEN 948A-50 Remote Alarm/Meter is automat ic and does not require opera tor attenti ...

  • Cardinal Gates 948A-40 - page 12

    (Blank Page) ...

  • Cardinal Gates 948A-40 - page 13

    4-1 Secti o n 4 Maintenance, Calibration, and Troubleshooting 4.1 Maintenance The 948A-40 Remote Alarm and 948A-50 Re mote Alarm/Meter require no routine maintenance other than periodic calibration for the 948A-50. Refer to calibration for further informat ion. 4.2 Calibration The 948A-50 requires calibration befo re it is initially placed into ser ...

  • Cardinal Gates 948A-40 - page 14

    4-2 Troubleshooting cons ists of checking the field wiring; re fer to loop drawing 945-3 in Appendix A. If a problem develops with the remote alarm/meter, refer to the applicable drawings locate d in Appendix A and to TP948A for the factory test procedure. Should it be nec essary to return the remote alarm/ mete r during the warranty period, contac ...

  • Cardinal Gates 948A-40 - page 15

    A-1 Appendix A Applicable Drawings and Bill of Materials A.1 Drawings Drawing Number Description GEL948A-50 Dimensional Outline 948A-40-5 Assembly Drawing w/o Meter 948A-50-5 948A-40/ 948A-50 Assembly Drawing 948A-50-3 Schematic Diagram 945-3 Loop Diagram 945A-3 Loop Diagram WL948A-40-5 Wire List WL948A-50-5 Wire List TP948A Test Procedure A.2 Bill ...

  • Cardinal Gates 948A-40 - page 16

    Radiation Management Services For additional information, please contact Radiation Management Services business of Cardinal Health at 440.248.9300. © 2004 Cardinal Health, Inc. or one of its subsidiaries All rights reserved. Manual No. 948A-50-1 Rev. 2 04 aug 04 Cardinal Health 6045 Cochran Road Cleveland, Ohio 44139 www.cardinal.com/rms ...

Fabricant Cardinal Gates Catégorie Automobile Alarm

Les documents que nous recevons du fabricant de l'appareilCardinal Gates 948A-40 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cardinal Gates
- manuels d’utilisations 948A-40
- fiches produit Cardinal Gates
- dépliants
- ou étiquettes-énergie Cardinal Gates 948A-40
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cardinal Gates 948A-40.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cardinal Gates 948A-40, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cardinal Gates 948A-40. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cardinal Gates 948A-40.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Cardinal Gates 948A-40, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cardinal Gates 948A-40 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cardinal Gates 948A-40.

Le manuel d’utilisation complet Cardinal Gates, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cardinal Gates 948A-40 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cardinal Gates 948A-40, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCardinal Gates 948A-40 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cardinal Gates 948A-40 - qui devraient nous aider dans les premières étapes lors de l'utilisation Cardinal Gates 948A-40
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cardinal Gates 948A-40
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cardinal Gates 948A-40 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cardinal Gates 948A-40?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cardinal Gates 948A-40, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cardinal Gates 948A-40 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (1)

detlev

I need a manual in german to see how to reanimate my old protrainer XT