    www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-COMM2-EX Dual Por t ISA RS-232/422/485 Inter face Board Shop online at ...

  • Omega Engineering OMG-COMM2-EX - page 2

    Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sale ...

  • Omega Engineering OMG-COMM2-EX - page 3

    Contents I NTRODUCTION ..........................................................................1 O VERVIEW ................................................................................................ 1 W HAT ’ S I NCLUDED ................................................................................ 1 F ACTORY D EFAULT S ETTINGS ......... ...

  • Omega Engineering OMG-COMM2-EX - page 4

    RS - 232 ..................................................................................................... 12 RS - 422 ..................................................................................................... 12 RS - 485 ..................................................................................................... 13 A PPENDI ...

  • Omega Engineering OMG-COMM2-EX - page 5

    Introduction OMG - COMM2 - EX Page 1 Introduction Overview The OMG - COMM2 - EX provides the PC with 2 asynchronous serial ports providing a versatile interface field selectable as RS - 232 for modems, printers and plotters, as well as RS - 422/485 for industrial automation a nd control applications. What’s Included The OMG - COMM2 - EX is shippe ...

  • Omega Engineering OMG-COMM2-EX - page 6

    Card Setup OMG - COMM2 - EX Page 2 Card Setup The OMG - COMM2 - EX contains several jumper straps which must be set for proper operation. Addres s Selection Each port on the OMG - COMM2 - EX occupies eight consecutive I/O locations. A DIP - switch is used to set the base address for these locations. Be careful when selecting the base address as som ...

  • Omega Engineering OMG-COMM2-EX - page 7

    Card Setup OMG - COMM2 - EX Page 3 Port Enable / Disable Each port on the OMG - COMM2 - EX can be enabled or disabled with switch position 8 on the DIP - switch. The port is enabled with the switch ‘On’ or ‘Closed’ and disabled when ‘Off’ or ‘Open’. If any port is disabled, be sure to disable the interrupt request for that port by r ...

  • Omega Engineering OMG-COMM2-EX - page 8

    Card Setup OMG - COMM2 - EX Page 4 Interrupt Modes Headers E9 and E10 select the interrupt modes for each port. Each port must be set in the correct mode to insure proper installation. E10 sets Port 1 and E9 sets Port 2 ‘ N ’ indicates the ( N )ormal, single interrupt per port mode. ‘ S ’ Indicates the ( S )hared interrupt mode, wh ich allo ...

  • Omega Engineering OMG-COMM2-EX - page 9

    Card Setup OMG - COMM2 - EX Page 5 Set the jumper to ‘ S ’ if you are usin g more than one OMG - COMM2 - EX in a bus or you wish to completely remove the pull - down resistor for hardware compatibility. Setting the adapter in this configuration when it is not accompanied by a pull - down resistor will prevent the ports from triggering an interr ...

  • Omega Engineering OMG-COMM2-EX - page 10

    Installation OMG - COMM2 - EX Page 6 Installation The OMG - COMM2 - EX can be installed in any of the PC expa nsion slots, but to access the ‘AT’ or (E)ISA IRQs (10 - 15) it must be installed in one of the 16 bit slots. The OMG - COMM2 - EX contains several jumper straps for each port which must be set for proper operation prior to installing t ...

  • Omega Engineering OMG-COMM2-EX - page 11

    Technical Description OMG - COMM2 - EX Page 7 Technical Description The OMG - COMM2 - EX adapter utilizes the 16550 UART chip. This chip features programmable baud rate, data format, interrupt control and has a 16 byte transmit and receive FI FO. Features • Full independent operation of ports allowing two ports RS - 232, two ports RS - 422/485 or ...

  • Omega Engineering OMG-COMM2-EX - page 12

    Technical Description OMG - COMM2 - EX Page 8 Connector Pin Assignments RS - 232 (Male DB9) Name Pin # Mode TD Transmit Data 3 Output RTS Request To Send 7 Output DTR Data Term Ready 4 Output GND Ground 5 RD Receive Data 2 In put DCD Data Carrier Detect 1 Input DSR Data Set Ready 6 Input CTS Clear To Send 8 Input RI Ring Indicator 9 Input Note: The ...

  • Omega Engineering OMG-COMM2-EX - page 13

    Specifications OMG - COMM2 - EX Page 9 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 158º F) Humidity Rang e 10 to 90% R.H. Non - Condensing 10 to 90% R.H. Non - Condensing Manufacturing • IPC 610 - B Class - III standards are adhered to wi ...

  • Omega Engineering OMG-COMM2-EX - page 14

    Appendix A - Troubleshooting OMG - COMM2 - EX Page 10 Appendix A - Troubleshooting Serial Utility test software is supplied wit h the adapter and will be used in the troubleshooting procedures. By using this software and following these simple steps, most common problems can be eliminated without the need to call Technical Support. 1. Identify all ...

  • Omega Engineering OMG-COMM2-EX - page 15

    Appendix B - How To Get Assistance OMG - COMM2 - EX Page 11 Appendix B - How To Get Assistance Please refer to Troubles hooting Guide prior to calling Technical Support. 1. Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed please see below. 2. When calling for technical assistance, please have your use ...

  • Omega Engineering OMG-COMM2-EX - page 16

    Appendix C - Electrical Interface OMG - COMM2 - EX Page 12 Appendix C - Electrical Interface RS - 232 Quite possibl y the most widely used communication standard is RS - 232. This implementation has been defined and revised several times and is often referred to as RS - 232 or EIA/TIA - 232. The IBM PC computer defined the RS - 232 port on a 9 pin ...

  • Omega Engineering OMG-COMM2-EX - page 17

    Appendix C - Electrical Interface OMG - COMM2 - EX Page 13 RS - 485 RS - 485 is backwardly compatible with RS - 422; however, it is optimized for partyline or multi - drop applications. The output of the RS - 422/485 driver is capable of being Active (enabled) or Tri - State (disabled). This capability allows multiple ports to be connected in a mul ...

  • Omega Engineering OMG-COMM2-EX - page 18

    Appendix D - Asynchronous Communications OMG - COMM2 - EX Page 14 Appendix D - Asynchronous Communications Serial data co mmunications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handshaking, and character framing (start/stop bits) ...

  • Omega Engineering OMG-COMM2-EX - page 19

    Appendix E - Silk - Screen OMG - COMM2 - EX Page 15 Appen dix E - Silk - Screen 3.9" 6.9" 4.2" ...

  • Omega Engineering OMG-COMM2-EX - page 20

    Appendix F - Compliance Notices OMG - COMM2 - EX Page 1 6 Appendix F - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the F CC Rules. These limits are designed to provide reasonable protection against harmful i ...

  • Omega Engineering OMG-COMM2-EX - page 21

    W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures that OME GA ? ...

  • Omega Engineering OMG-COMM2-EX - page 22

    M1691/0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, C ...

Fabricant Omega Engineering Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilOmega Engineering OMG-COMM2-EX peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega Engineering
- manuels d’utilisations OMG-COMM2-EX
- fiches produit Omega Engineering
- dépliants
- ou étiquettes-énergie Omega Engineering OMG-COMM2-EX
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega Engineering OMG-COMM2-EX.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega Engineering OMG-COMM2-EX, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega Engineering OMG-COMM2-EX. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega Engineering OMG-COMM2-EX.

Manuel d’utilisation complet de l’appareil Omega Engineering OMG-COMM2-EX, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega Engineering OMG-COMM2-EX par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega Engineering OMG-COMM2-EX.

Le manuel d’utilisation complet Omega Engineering, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega Engineering OMG-COMM2-EX - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega Engineering OMG-COMM2-EX, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega Engineering OMG-COMM2-EX qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega Engineering OMG-COMM2-EX - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega Engineering OMG-COMM2-EX
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega Engineering OMG-COMM2-EX
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega Engineering OMG-COMM2-EX dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega Engineering OMG-COMM2-EX?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega Engineering OMG-COMM2-EX, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega Engineering OMG-COMM2-EX il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)