    INSTRUCTION MANUAL OXYGEN DEFICIENCY MONITOR (Model 55) T10008 Rev A1 ...

  • Sierra Monitor Corporation 55 - page 2

    OXYGEN DEFICIENCY MONITOR PAGE 1 TABLE OF CONTENTS 1. Introduction .................................................................................................... 1 2. Features ......................................................................................................... 2 3. Mechanical Description .................................. ...

  • Sierra Monitor Corporation 55 - page 3

    OXYGEN DEFICIENCY MONITOR PAGE 1 1. Introduction 1.1 The SMC Model 55 is a portable oxygen efficiency monitor for personnel in confined work pla ces. It is self-contained, light weight and battery operat ed. It does not require any adjustments by the user other than routine cali brations. The monitor re ads true percent oxygen in the presence of an ...

  • Sierra Monitor Corporation 55 - page 4

    OXYGEN DEFICIENCY MONITOR PAGE 2 2. Features 2.1 Features of the Model 55 include: • Temperature Stable • Barometric Pressure Insensitive • Large LCD digital display • High accuracy over temperature range 0-50 o C • Fast response -90% full scale in 10 seconds • Visual Alarm – LED provided on top of case • External Earphone for noisy ...

  • Sierra Monitor Corporation 55 - page 5

    OXYGEN DEFICIENCY MONITOR PAGE 3 3. Mechanical Description 3.1 The Model 55 is housed i n a rugged, high impact en closre. The sliding ON/OFF power switch is located on the left side, the calibration potentiometer is acce ssible on the ri ght side and the digital display is on the fro nt surface. The top of the monitor and the digital display is on ...

  • Sierra Monitor Corporation 55 - page 6

    OXYGEN DEFICIENCY MONITOR PAGE 4 4. Alarms 4.1 LOW OXYGE N CODITION: When the % oxygen fall s below 19.5 (factory set) the digital display will be augmented by an audi ble alarm when using either int ernal or external sensor. The red LE D will also truno on to provide visual indicat ion. If an earphone is in use the alarm will only sou nd through t ...

  • Sierra Monitor Corporation 55 - page 7

    OXYGEN DEFICIENCY MONITOR PAGE 5 Figure 1 ...

  • Sierra Monitor Corporation 55 - page 8

    OXYGEN DEFICIENCY MONITOR PAGE 6 5. Operation 5.1 Turn the ON/OFF switch to “ON” po sition. 5.2 Display reads percent oxygen. 5.3 If the alarm sounds the percentage oxygen has d ropped below the present alarm lever (factory se t to 19.5%). The alarm will turn off automatically when the oxygen concentration ri ses above the alarm level. 5.4 If t ...

  • Sierra Monitor Corporation 55 - page 9

    OXYGEN DEFICIENCY MONITOR PAGE 7 6. Calibration NOTE: This instruction assumes that o nly the internal sensor is in use (external probe disconnected). See opti on instructio ns for calibration of external probe. 6.1 Turn the monitor “ON” and place it in an enviro nment containing 20.9% oxygen and 79.1% nitrogen. This can be supplied from a cali ...

  • Sierra Monitor Corporation 55 - page 10

    OXYGEN DEFICIENCY MONITOR PAGE 8 7. Sensor Replacement 7.1 Sensors for the Model 55 are provided in a seale d bag to prevent depletion of the electrolyte pr ior to required u se. Sensor depletion begins when the bad seal is br oke n. 7.2 Remove the four screws from the rear of the monitor and open the case. 7.3 Remove the sensor from the clamp i n ...

  • Sierra Monitor Corporation 55 - page 11

    OXYGEN DEFICIENCY MONITOR PAGE 9 FIGURE 2 Sensor Installation ...

  • Sierra Monitor Corporation 55 - page 12

    OXYGEN DEFICIENCY MONITOR PAGE 10 8. Battery Replacement 8.1 When the “BAT” indicator is displaye d approximately 8 hours of battery life remain. 8.2 Slide off the battery cover loca ted on the lower rear of the unit. Remove the battery and disconnect. 8.3 Connect a new battery and ca refully install it in the compartment taking care to stow th ...

  • Sierra Monitor Corporation 55 - page 13

    OXYGEN DEFICIENCY MONITOR PAGE 11 9. Remote Sensor Option 9.1 Use the remote sensor option to check the confined environment before entry. 9.2 Plug the probe into the top of the monitor and loop the cabl e securely around the belt clip. Wh en the remote probe is plu gged in the internal sensor is disabled and the displ ay reads the remote pro be co ...

  • Sierra Monitor Corporation 55 - page 14

    OXYGEN DEFICIENCY MONITOR PAGE 12 10. NOTICE The enclosed replacement sens or for your Model 55 Pers onal Oxygen Monitor is an enhanced version which will provide twice the operating life compared to sens ors shipped prior to September, 2004. The enclosed sensor will operate for t wo years. To insure maximum life of your new sensor, please perform ...

  • Sierra Monitor Corporation 55 - page 15

    OXYGEN DEFICIENCY MONITOR PAGE 13 11. Specifications SENSOR OXYMAX™ oxygen concentration transducer. DISPLAY 3 digit LCD, %0 2 in air from 0% to 25.0% with low battery indicator. ACCURACY + 3% of full scale from 10 to 50 o C + 4% of full scale from 0 to 50 o C RESPONSE 10 seconds to 90% indication RESOLUTION 0.1% Oxygen SENSOR LIFE 21 months in a ...

  • Sierra Monitor Corporation 55 - page 16

    OXYGEN DEFICIENCY MONITOR PAGE 14 CONTROLS ON/OFF switch. CALIBRATION ADJUSTMENT Calibrate both internal and external sensors against dry 0 2 /N 2. Both calibration adjustment s are with jeweler screwdriver. ALARAMS Audible: Factory set to alarm below 19.5% 0 2. Visual: LED lights when Audible Alarm sounds. CONNECTIONS Alarm earphone jack. External ...

  • Sierra Monitor Corporation 55 - page 17

    OXYGEN DEFICIENCY MONITOR PAGE 15 WEIGHT 11 Oz. (0.3 Kg) INTERFERING GASES Ozone, chlorine and other highly oxidizing gases will interfere to the extent of their oxygen equivalent. Highly corrosive atmosphere will cause premature failure. CASE Three-piece, molded of high impact plastic. ...

  • Sierra Monitor Corporation 55 - page 18

    OXYGEN DEFICIENCY MONITOR PAGE 16 12. Limited Warranty SIERRA MONITOR CORPORATION warrants its produ cts to be free from defects in workmanship or material under normal use and service for tw o years after date of shipment. SMC w ill repair or replace without charge any equipment found to be defective during the warranty period. Final determination ...

  • Sierra Monitor Corporation 55 - page 19

    OXYGEN DEFICIENCY MONITOR PAGE 17 13. NOTICE – New 2-year Oxygen Sensor Thank you for your order for a SPC21111 Ox ygen Sensor Assembly for your Model 55 Pe rsonal Oxygen Monitor. In this shipment you will find the new Sierra Monitor 2-y ear Oxygen sensor for your Model 55 Personal Oxygen Monitor. Thi s enhan ced v ersion will provide twice the o ...

  • Sierra Monitor Corporation 55 - page 20

    OXYGEN DEFICIENCY MONITOR PAGE 18 WARRANTY REGISTRATION SERIAL # Model 55 Oxygen Deficiency Monitor Name: Company: Address: City/State /Zip: Phone: I am also intere sted in the following Sierra M onitor Product s: Remote Probe for my Model 55 Oxygen Monitor Spare parts for Model 55 Sentry – Fixed installation monitor for Combustible, Oxygen, and ...

Fabricant Sierra Monitor Corporation Catégorie Carbon Monoxide Alarm

Les documents que nous recevons du fabricant de l'appareilSierra Monitor Corporation 55 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Sierra Monitor Corporation
- manuels d’utilisations 55
- fiches produit Sierra Monitor Corporation
- dépliants
- ou étiquettes-énergie Sierra Monitor Corporation 55
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Sierra Monitor Corporation 55.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Sierra Monitor Corporation 55, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Sierra Monitor Corporation 55. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Sierra Monitor Corporation 55.

Manuel d’utilisation complet de l’appareil Sierra Monitor Corporation 55, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Sierra Monitor Corporation 55 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Sierra Monitor Corporation 55.

Le manuel d’utilisation complet Sierra Monitor Corporation, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Sierra Monitor Corporation 55 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Sierra Monitor Corporation 55, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSierra Monitor Corporation 55 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Sierra Monitor Corporation 55 - qui devraient nous aider dans les premières étapes lors de l'utilisation Sierra Monitor Corporation 55
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Sierra Monitor Corporation 55
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Sierra Monitor Corporation 55 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Sierra Monitor Corporation 55?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Sierra Monitor Corporation 55, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Sierra Monitor Corporation 55 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)