    Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www .cda.eu HG6100 & HG6120 Gas Hobs Manual for Installation, Use and Maintenance ...

  • CDA HG6100 - page 2

    2 Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that we reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance. This appliance is not designed to be used by people (includi ...

  • CDA HG6100 - page 3

    3 safety (L VD) and Electromagnetic interference compatibility (EMC). Parts intended to come into contact with food conform to EEC/89/109 . IMPORT ANT INFORMA TION FOR CORRECT DISPOSAL OF THE PRODUCT IN A CCORD ANCE WITH EC DIRECTIVE 2002/96/EC. At the end of its working life, the product must be taken to a special local authority waste collection ...

  • CDA HG6100 - page 4

    4 • This hob (Class 3) has been designed for use only as a cooking appliance. Any other use (e. g. heating rooms) should be considered incorrect and potentially dangerous. • These instructions are valid only for the countries of destination, the symbols of which appear on the cover and on the appliance. ...

  • CDA HG6100 - page 5

    5 Using Y our Hob Fig. 1 Gas burners: Gas flow to the burners is controlled by the control knobs (5, 6, 7 and 8 on the diagrams on the next page). There are 3 positions shown on the control panel. T urning the control knob to the positions shown below achieves the following: Closed (OFF position) Maximum position: Provides fast boiling function Mi ...

  • CDA HG6100 - page 6

    6 K ey to Fig 2 Gas burners: 1. Semi-Rapid burner 1.85k W 2. Semi-R apid burner 1.85k W 3. Rapid burner 3. 0k W 4. Auxiliary burner 1. 0k W Control panel: 5. Back right burner control knob 6. Back left burner control knob 7 . Front left burner control knob 8. Front right burner control knob These appliances are class 3 Fig. 2 5 6 7 8 1 4 3 2 ...

  • CDA HG6100 - page 7

    7 Igniting the Burners The hob is fitted with a flame failure device. Flame failure devices operate by shutting o the supply of gas to the burner in the event that the flame is extinguished accidentally . T o ignite the burners, follow these instructions: 1. Lightly press the control knob down and turn the knob anti- clockwise to the maximum ...

  • CDA HG6100 - page 8

    8 Fig. 4 Ecient Use of Y our Hob The hob is equipped with burners of dierent sizes, designed to accommodate most shapes and sizes of pan. For best results, only use pans with flat bottoms and choose an appropriate burner depending on the size of the pan. The most ecient use of the hob is shown below , where the pan and burner are correctl ...

  • CDA HG6100 - page 9

    9 Care and Maintenance As the hob has a stainless steel or enamel surface, you should use a nonabrasive cleaner . Any abrasive cleaner (including Cif ) will scratch the surface and could erase the control panel markings. Stainless steel can be eectively cleaned by simply using a dilute solution of water and mild detergent and drying to a shine w ...

  • CDA HG6100 - page 10

    10 T otal rated gas input : 7 . 7k W Mains electrical voltage: 230 – 240V ac, 50Hz T otal rated electrical consumption: <1W If Y our Hob is Not W orking 1. Check that the mains supply has not been switched o . 2. Check that the fuse in the spur has not blown. 3. Ensure that the burner components are not ex cessively soiled as this can lead ...

  • CDA HG6100 - page 11

    11 Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED T O THE MAINS SUPPL Y B Y A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWIT CHED FUSE SPUR OUTLET AND PROTECTED B Y A 3A FUSE. W e recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E. T ...

  • CDA HG6100 - page 12

    12 Gas Supply R equirements IMPORT ANT : THIS APPLIANCE SHOULD BE FITTED B Y A GAS SAFE REGIS TERED FITTER OR OTHER SUIT ABL Y QU ALIFIED PERSON. • This installation must comply with the Gas Safety (installation and use) R egulations 1984. • This appliance is category II2H3+ and is designed for use in the UK and Ireland. The installation must c ...

  • CDA HG6100 - page 13

    13 Room V olume (m 3 ) 5 6 to 10 6 to 11 11 or more Air V ent Required (cm 2 ) 100 50 No permanent vent required if a door opens to the outside None required V entilation All rooms require a window or equivalent (e.g. a door) which can be opened. Some rooms require a permanent vent in addition to a win- dow (see below). This unit must not be used i ...

  • CDA HG6100 - page 14

    14 Natural Gas to LPG Conversion This hob can be converted from natural gas to propane operation at a nominal inlet pressure of 37mbar , or butane operation at a nominal inlet pressure of 28/30mbar . This conversion must only be carried out by a competent person (i.e. a Gas Safe registered fitter). Instructions to fit replacement injectors: 1. Di ...

  • CDA HG6100 - page 15

    15 LPG to Natural Gas Conversion This hob can be converted from propane operation at a nominal inlet pressure of 37mbar or butane operation at a nominal inlet pressure of 28/30mbar to natural gas at 20mbar . This conversion must only be carried out by a competent person (i.e. a Gas Safe registered fitter). Required: • 7mm AF nut spinner • Repl ...

  • CDA HG6100 - page 16

    16 Fitting the Hob Unpacking the hob: T ake care not to lose or mishandle any parts. Fitting position of the hob: This appliance must be installed a minimum of 50mm from any back wall and a minimum of 150mm away from any adjacent vertical surfaces, e.g. a tall cupboard end panel. This may be reduced to 100mm if the adjacent surface is resistant to ...

  • CDA HG6100 - page 17

    17 Fig. 7 15mm V entilation slot > 30mm withstanding temperatures 65°C above ambient or greater (typically 80-90°C). • If there is no oven to be built in below the hob it is recommended that, an isolation shelf should be fitted to protect the user from high temperatures. If the hob is to be installed above a working drawer , then a partitio ...

  • CDA HG6100 - page 18

    18 How to Install the Hob How to install the hob: Overall dimensions of the hob: Width: 580mm Depth: 500mm W orktop cut-out dimensions: Width: 557mm Depth: 477mm 1. Make the required hole in the worktop. Note that before doing this, check the instructions supplied with any cooker hood to ensure that you will have the required clearance. The cut-out ...

  • CDA HG6100 - page 19

    19 400mm 750mm Fig. 8 Fig. 9 Fig. 10 Fig. 11 >61.5mm 150mm 150mm 557mm 477mm 3cm 4cm ...

  • CDA HG6100 - page 20

    20 NO TES: ...

  • CDA HG6100 - page 21

    21 NO TES: ...

  • CDA HG6100 - page 22

    22 Energy Eciency Information A) Measurement and calculation methods • The gas hob was CE approval according to the Gas Appliance Directives 2009/142/EC. • The energy eciency of this gas hob was tested and measured according to EN 30-2-1-1998+A1-2003+A2-2005. • The semi-rapid burner and rapid burner were tested separately; the auxiliary ...

  • CDA HG6100 - page 23

    23 E & O E. All instructions, dimensions and illustrations are provided for guidance only . CDA reserve the right to change specifications without prior notice. Attribute Symbol Units Model Identification HG6100 HG6120 Annual Energy Consumption Built in Built in Time increase factor 4.0 4.0 Fluid Dynamic Efficiency EE Gas burner Aux:NA / SR:56 ...

  • CDA HG6100 - page 24

    Please contact our Customer Care Department for Service on the details below Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www. cda.eu © CDA 2015 ...

Fabricant CDA Catégorie Stove

Les documents que nous recevons du fabricant de l'appareilCDA HG6100 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques CDA
- manuels d’utilisations HG6100
- fiches produit CDA
- dépliants
- ou étiquettes-énergie CDA HG6100
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation CDA HG6100.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation CDA HG6100, manuels d’entretien, brefs manuels ou manuels de l’utilisateur CDA HG6100. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit CDA HG6100.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil CDA HG6100, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser CDA HG6100 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs CDA HG6100.

Le manuel d’utilisation complet CDA, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel CDA HG6100 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières CDA HG6100, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCDA HG6100 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil CDA HG6100 - qui devraient nous aider dans les premières étapes lors de l'utilisation CDA HG6100
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de CDA HG6100
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service CDA HG6100 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de CDA HG6100?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec CDA HG6100, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec CDA HG6100 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)