    Multimeter Selection Guide Fluke 8508A & Agilent 3458/HFL TECHNICAL INFORMATION When comparing two products features and specification using sales information it is often difficult to determine which pr oduct will meet the needs of your specific application. This is mostly because each supplier will define specifications using alternate methods ...

  • Fluke 3458/HFL - page 2

    DC Volt age ±( ppm of se tt ing + ppm of r ange) , r el ati ve t o cal i brat i on sta nd ar ds use d . Cali brat i on I nt e rv al 365 day , ±1°C of l ast TC AL R ange 1281 H P3458/HF L 8508A 120. 00000m V - 4 + 3 - 199. 999999m V 6 + 0. 5 - 2. 7 + 0.5 1. 20000000V - 3 + 0. 3 - 1. 99999999V 3 + 0.2 - 2. 7 + 0. 2 12. 000000V - 3 + 0. 05 - 19. 99 ...

  • Fluke 3458/HFL - page 3

    DC C urrent ±(ppm of setting + ppm of range), relative to calib ration standards used. Calibration Interval 365 day , ±1°C of last TCAL Range 1281 HP3458/HFL 8508A 120.000nA - 30 + 400 - 1.200000µA - 20 + 40 - 12.000000µA - 20 + 10 - 120.00000µA - 20 + 8 - 199.99999µA 25 + 2 - 6.5 + 2.0 1.2000000mA - 20 + 5 - 1.9999999mA 25 + 2 - 6.5 + 2.0 1 ...

  • Fluke 3458/HFL - page 4

    Resistance ±(ppm of setting + ppm of range), relative to calibration standa rds used. Calibration Interv al 365 day, ±1°C of las t TC AL Range 1281 HP3458/HFL 8508A 1.99999999 Ohm - - 10 + 2.0 12.00000 Ohm - 10 + 5 - 19.9999999 Ohm 12 + 1.0 - 7.0 + 0.7 120.00000 Ohm - 8 + 5 - 199.999999 Ohm 8 + 0.3 7.0 + 0.25 1.2000000 kOhm - 7 .5 + 0.5 - 1.9999 ...

  • Fluke 3458/HFL - page 5

    A C Current ±(ppm of setting + ppm o f range), rela tive to cal ibrati on standards use d. Calibration Interval 365 day, ±1°C of last TCAL Range Frequency 1281 HP3458/HFL 8508A 120.0000µA 10Hz - 20Hz - 4000 + 200 - 20Hz - 45Hz - 1500 + 200 - 45Hz - 100Hz - 600 + 200 - 100Hz - 5kHz - 600 + 200 - 199.9999µA 1Hz - 10Hz - - 250 + 100 10Hz - 5kHz 2 ...

  • Fluke 3458/HFL - page 6

    A C Voltage ± (ppm of setting + ppm of range), relative to cali bration standards used. Cali bration Interval 365 day, ±1°C of last TCA L Range Frequ ency 1281 HP3458/HFL 8508A 12.00000 mV 1Hz - 40Hz - 300 + 300 - 40Hz - 1kHz - 200 + 110 - 1kHz - 20 kHz - 300 + 110 - 20kHz - 50k Hz - 1000 + 110 - 50kHz - 100 kHz - 5000 + 110 - 100kHz - 300kHz - ...

  • Fluke 3458/HFL - page 7

    A C Voltage ± (ppm of setting + ppm of range), relative to cali bration standards used. Calibration Int erval 365 day, ±1°C of last T CAL Range Frequency 1281 HP3458/HFL 8508A 19.99999V 1Hz - 10Hz - - 100 + 60 10Hz - 40Hz - - 100 + 10 40Hz - 100Hz 80 + 10 - 80 + 10 100Hz - 2kHz 60 + 10 - 60 + 10 2kHz - 10kHz 80 + 10 - 80 + 10 10kHz - 30kHz 200 + ...

  • Fluke 3458/HFL - page 8

    Fluke 8508A 3458/HFL 8508A vs 3458/HFL Functional & Versatility Parameters Comments Full Scale (dc & ac Voltage) 200mV, 2V, 20V, 200V, 1050Vrms 120mV, 1.2V, 12V, 120V, 1050Vdc (ac = 700Vrms) 8508A maintains >10Gohm input impedance to 20Vdc. This compares with 12V on 3458/HFL. The 8508A 1050Vrms measurement is often used to calibrate cali ...

  • Fluke 3458/HFL - page 9

    8508A vs 3458/HFL Functional & Versatility Parameters Comments High Resistance Measurement (compliance voltage) Test Voltage or Full Scale stimulus = 200V Test Voltage or Full Scale stimulus @ 1.2G Ω = 5V Reduces errors when performing high resistance measurement (feature available 8508A - 20M Ω to 20G Ω range only) Tru-Ohms or Offset Com ...

  • Fluke 3458/HFL - page 10

    ACV & DCV 4 wire input. Selectable 2 and 4-wire measurement. Unavailable 4-wire sense measurement support improved accuracy when calibrating calibrators with 4 wire sense output. Remote switched GUARD Terminal IEEE controlled Manual Switch IEEE control of GUARD terminal helps fully automate calibration without need for manual switching. Read ra ...

  • Fluke 3458/HFL - page 11

    8508A vs 3458/HFL Ease of Use Parameters Comments Rear input switched remotely using IEEE 488 commands Yes No The 3458/HFL must be switched manually using a front panel button. Instrument simultaneously displays Frequency as well as the AC voltage & current. Yes Selectable Requires further commands or key presses to determine frequency. Two cha ...

  • Fluke 3458/HFL - page 12

    8508A Options and Accessories: Model Description 8508A 8.5 digit Reference Multimeter 8508A/01 8.5 digit Reference Multimeter with Rear Input Ratio measurement Accessories 8508A-SPRT Standard Platinum Resistanc e Thermometer 8508A-PRT Platinum Resistance Thermometer 8508A-LE AD Comprehensive Measuremen t Lead Kit Y8508 Rack Mount Kit Y8508S Rack Mo ...

  • Fluke 3458/HFL - page 13

    Notes: ...

Fabricant Fluke Catégorie Wireless Office Headset

Les documents que nous recevons du fabricant de l'appareilFluke 3458/HFL peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Fluke
- manuels d’utilisations 3458/HFL
- fiches produit Fluke
- dépliants
- ou étiquettes-énergie Fluke 3458/HFL
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Fluke 3458/HFL.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Fluke 3458/HFL, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Fluke 3458/HFL. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Fluke 3458/HFL.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Fluke 3458/HFL, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Fluke 3458/HFL par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Fluke 3458/HFL.

Le manuel d’utilisation complet Fluke, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Fluke 3458/HFL - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Fluke 3458/HFL, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFluke 3458/HFL qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Fluke 3458/HFL - qui devraient nous aider dans les premières étapes lors de l'utilisation Fluke 3458/HFL
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Fluke 3458/HFL
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Fluke 3458/HFL dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Fluke 3458/HFL?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Fluke 3458/HFL, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Fluke 3458/HFL il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)