Manuel d’utilisation LSI 40909G-S

56 pages 0.15 mb
Télécharger

Aller à la page of 56

Summary
  • LSI 40909G-S - page 1

    ® S14062 LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solar is USER’S GUIDE February 2001 V ersion 1.0 ...

  • LSI 40909G-S - page 2

    ii Electroma gnetic Compatibility Notices This device complies with P ar t 15 of the FCC Rules. Operation is subject to the f ollowing two conditions: 1. This device ma y not cause har mful interference , and 2. This device m ust accept any interf erence received, including interference that ma y cause undesired operation. This equipment has been t ...

  • LSI 40909G-S - page 3

    iii This document contains proprietar y information of LSI Logic Cor poration. The inf or mation contained herein is not to be used by or disclosed to third parties without the e xpress written per mission of an officer of LSI Logic Cor poration. LSI Logic products are not intended f or use in lif e-suppor t appliances, de vices, or systems. Use o ...

  • LSI 40909G-S - page 4

    iv ...

  • LSI 40909G-S - page 5

    Pref ace v Preface This book is the primar y reference and user’ s guide f or the LSI Logic LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solaris board. It contains a complete functional description for the LSI40909G-S as w ell as complete ph ysical and electrical specifications. A udience This document assumes that you ha ve some f ami ...

  • LSI 40909G-S - page 6

    vi Pref ace Related Publications LSIFC909 Fibre Channel I/O Processor T echnical Man ual, Order Number S14029.A Revision Recor d Revision Date Remarks 1.0 02/01 First printing. ...

  • LSI 40909G-S - page 7

    Contents vii Contents Chapter 1 LSI40909G-S Description 1.1 General Description 1-1 1.2 F eatures 1-1 1.2.1 PCI Interf ace 1-1 1.2.2 FC Interf ace 1-2 1.2.3 Board Characteristics 1-2 1.2.4 FC Link Activity/Link F ault LED 1-3 Chapter 2 Installing the LSI40909G-S 2.1 Quick Installation Procedure 2-1 2.2 Detailed Installation Procedure 2-2 2.2.1 Bef ...

  • LSI 40909G-S - page 8

    viii Contents Chapter 4 LSI40909G-S T echnical Characteristics 4.1 Ph ysical Environment 4-1 4.1.1 Ph ysical Characteristics 4-1 4.1.2 Electrical Characteristics 4-2 4.1.3 Thermal, Atmospher ic Characteristics 4-2 4.1.4 Electromagnetic Compliance 4-3 4.1.5 Saf ety Characteristics 4-3 4.2 Operational En vironment 4-3 4.2.1 The PCI Interf ace 4-3 4.2 ...

  • LSI 40909G-S - page 9

    LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solaris 1-1 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 12 pc 12.938 pc 13.851 pc 48.583 pc 52.5 pc 34.5 pc 34.732 pc Chapter 1 LSI40909G-S Description This chapter describes the LSI40909G-S PCI to Fibre Channel (FC) Host Adapter board and includes these topics: • Section 1.1, “General Desc ...

  • LSI 40909G-S - page 10

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 1-2 LSI40909G-S Description The PCI interf ace includes these f eatures: • Full 64-bit DMA bus master • LSIFC909 functionality: – Zero wait-state b us master data bursts up to 1 Kb yte – Complies with PCI Local Bus Specification, Re vision 2.2 – 3.3 V interf a ...

  • LSI 40909G-S - page 11

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc F eatures 1-3 1.2.4 FC Link Activity/Link Fault LED The LSI40909G-S provides a dual-purpose LED visible through the brac ket which indicates activity on the FC link when the LED is green. This LED tur ns yello w when there has been a fault on the FC link. ...

  • LSI 40909G-S - page 12

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 1-4 LSI40909G-S Description ...

  • LSI 40909G-S - page 13

    LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solaris 2-1 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 12 pc 12.938 pc 13.851 pc 48.583 pc 52.5 pc 34.5 pc 34.732 pc Chapter 2 Installing the LSI40909G-S This chapter provides instructions on how to install the LSI40909G-S and includes these topics: • Section 2.1, “Quick Installation Proce ...

  • LSI 40909G-S - page 14

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 2-2 Installing the LSI40909G-S 2.2 Detailed Installation Pr ocedure This section provides step-b y-step instructions for installing the LSI40909G-S. If y ou are experienced in these tasks, y ou ma y pref er to use Section 2.1, “Quick Installation Procedure . ” 2.2.1 ...

  • LSI 40909G-S - page 15

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc Detailed Installation Procedure 2-3 the edge; do not touch board components or gold connector contacts. The use of a static ground str ap is recommended. Step 5. Locate the slots f or PCI plug-in board installation. Ref er to the computer’ s user’ s manual to confir ...

  • LSI 40909G-S - page 16

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 2-4 Installing the LSI40909G-S Figure 2.1 Hard ware Connections for the LSI40909G-S Step 7. Carefully inser t edge connector J1 (see Figure 2.1 ) of the host adapter into the PCI slot. Make sure the edge connector is properly aligned bef ore pressing the board into place ...

  • LSI 40909G-S - page 17

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc Detailed Installation Procedure 2-5 Figure 2.2 Inserting the Host Adapter Step 8. Secure the board with the brac ket scre w (see Figure 2.2 ) before making the e xter nal FC link connection. Step 9. Connect the FC cable to the LSI40909G-S . 32-bit PCI Slots 64-bit PCI Sl ...

  • LSI 40909G-S - page 18

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc 2-6 Installing the LSI40909G-S ...

  • LSI 40909G-S - page 19

    LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solaris 3-1 Chapter 3 Software Installation This chapter describes the features and use of the LSI Logic/IntraServer de vice drivers f or the Solar is operating system 2.6, 2.7, and 2.8. This chapter includes these topics: • Section 3.1, “Installing the Sun SP ARC Solar is Fusion-MPT™ Dri ...

  • LSI 40909G-S - page 20

    3-2 Software Installation 3.1.1 Features The f ollowing f eatures of the LSI40909G-S minimize CPU utilization: • Uses state of the ar t Fusion-MPT interface , providing support f or FC , SCSI, and RAID de vices with a single binar y image. • Provides highly efficient, lo w CPU usage architecture. • Multipor t functionality minimizes slot usa ...

  • LSI 40909G-S - page 21

    Installing the Sun SP ARC Solaris Fusion-MPT™ Drivers 3-3 Step 2. When the banner is displa yed, press the Stop-A k eys to interrupt the boot process and stop at the ok prompt. Step 3. Use the show-devs command to list the system de vices. Y ou should see an output similar to the f ollowing e xample, as shown in Figure 3.1 : Figure 3.1 System Dev ...

  • LSI 40909G-S - page 22

    3-4 Software Installation 3.1.4 Identifying the FC Disks The probe-scsi-all command is used to identify the FC disk de vices on your LSI Logic/Intr aSer ver adapter , as sho wn in Figure 3.2 . Figure 3.2 FC Disk Devices Listing ok probe-scsi-all /pci@1f,0/pci@1/IntraServer,Ultra2-scsi@1 Target 0 Unit 0 Disk IBM DNES-309170W SA30 /pci@1f,0/pci@1/pci ...

  • LSI 40909G-S - page 23

    Installing the Sun SP ARC Solaris Fusion-MPT™ Drivers 3-5 If the FC disks on your LSI Logic/Intr aSer ver adapter are not identified by y our system, check the f ollowing: 1. Are all the FC cables correctly connected to the disk enclosure? 2. Is the disk enclosure powered up? 3. If the external disk enclosure required a loopback connector , is t ...

  • LSI 40909G-S - page 24

    3-6 Software Installation Figure 3.3 P ersistent Device Mapping ok show-disks a) /pci@1f,0/pci@1/IntraServer,fc@2/disk b) /pci@1f,0/pci@1/IntraServer,Ultra2-scsi@1/disk c) /pci@1f,0/pci@1,1/ide@3/cdrom d) /pci@1f,0/pci@1,1/ide@3/disk e) /pci@1f,0/pci@1,1/ebus@1/fdthree@14,3203f0 q) NO SELECTION Enter Selection, q to quit: a /pci@1f,0/pci@1/IntraSer ...

  • LSI 40909G-S - page 25

    Installing the itmpt Sun SP ARC Solaris FC Driver 3-7 T o clear an entr y in the persistent device map , use the clear-persistent command, as shown in Figure 3.4 : Figure 3.4 Clearing an Entry Entr y 1 has been deleted from the table , and the table is no w empty . 3.1.6 itmpt Device Driver The LSI Logic/IntraServer itmpt driver is designed to Sun ...

  • LSI 40909G-S - page 26

    3-8 Software Installation 3.2.1.1 Floppy Disk Install If you receiv ed the dr ivers on a flopp y diskette , f ollow these steps: Step 1. Place the diskette in the flopp y dr iv e and e x ecute the volcheck command to ensure the system sees the flopp y . Step 2. Change the director y to the root of the flopp y (e.g. " cd /floppy/floppy0 &qu ...

  • LSI 40909G-S - page 27

    Installing the itmpt Sun SP ARC Solaris FC Driver 3-9 Figure 3.5 pkgadd Procedure The following packages are available: 1 TImpt LSI Logic/IntraServer FusionMPT(tm) Fibrechannel/SCSI drivers (sparc) itmpt kit version 1.1 Select package(s) you wish to process (or 'all' to process all packages). (default: all) [?,??,q]: 1 Processing package ...

  • LSI 40909G-S - page 28

    3-10 Software Installation Figure 3.6 Completing Floppy Disk Installation See Figure 3.8 f or additional inf or mation. Figure 3.7 Completing Floppy Disk Installation (Continued) T o suppor t nonzero LUNs , which is default f or most RAID controllers such as the LSI Logic MetaStor ® ,y o u must edit the file /kernel/dr v/ssd.conf as shown in Figu ...

  • LSI 40909G-S - page 29

    Installing the itmpt Sun SP ARC Solaris FC Driver 3-11 Figure 3.8 /kernel/drv/ssd.conf Step 4. The itmpt device driver is no w installed. Reboot the machine to reconfigure the system and to recognize the ne w de vices. 3.2.1.2 Distribution File Install If you receiv ed the dr iv ers in an itmpt_install.tar .Z file, f ollow these steps: Step 1. Un ...

  • LSI 40909G-S - page 30

    3-12 Software Installation 3.2.2 Network Installation Pr ocedure If you are using y our LSI Logic/IntraSer ver adapter to suppor t your Sparc Solaris system disk, you must install the Solaris operating system using a network install. This section describes a complete installation of Solar is to a client system using LSI Logic/IntraServer FC adapter ...

  • LSI 40909G-S - page 31

    Installing the itmpt Sun SP ARC Solaris FC Driver 3-13 cd /floppy/floppy0 Step 3. Ex ecute the install.sh shell script to add the itmpt dr iver to the boot installation area: ./install.sh –n /export/home/install/Solaris_2.7 Notes: • F or Solaris 2.8 boot files, the director y would be /e xpor t/home/install/Solaris_2.8. • The message “majo ...

  • LSI 40909G-S - page 32

    3-14 Software Installation Note: Y ou can obtain the platf orm_group from a machine of the same type as the target client using the uname –m command . 3.2.2.4 Booting the Client Using the itmpt FC Driver Now y ou can begin the installation of the Solar is operating system to the client target machine using the boot and install ser ver . On the cl ...

  • LSI 40909G-S - page 33

    T roub leshooting 3-15 Notes: The message “major number maximum based on server , not client” can saf ely be ignored. Y our Sun machine will prompt you to allo w pow er saving automatic shutdown. Y ou must ans wer no to this question if you are using the LSI Logic/Intr aSer ver adapter to suppor t your boot disk. If you change the disk driv e c ...

  • LSI 40909G-S - page 34

    3-16 Software Installation itmpt<n>: Could not allocate memor y to read configuration data. The driver w as unable to allocate memory required to process the configuration data. This means that the configuration w as not properly deter mined. T o fix this you ma y need to manually configure the driver using the itmpt.conf file. itmpt< ...

  • LSI 40909G-S - page 35

    T roub leshooting 3-17 itmpt<n>: The adapter is malfunctioning or is of an unknown type. The driver is not ab le to communicate with the hardware . Y ou ma y need to update your driv er or your hardw are. itmpt<n>: The adapter is malfunctioning. – itmpt<n>: F ailed to create minor node required f or DMI interface . The driver wa ...

  • LSI 40909G-S - page 36

    3-18 Software Installation ...

  • LSI 40909G-S - page 37

    LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solaris 4-1 Chapter 4 LSI40909G-S T echnical Characteristics This chapter provides specific details about the ph ysical environment associated with the LSI40909G-S. This chapter includes these topics: • Section 4.1, “Ph ysical Environment, ” page 4-1 • Section 4.2, “Operational En vi ...

  • LSI 40909G-S - page 38

    4-2 LSI40909G-S T echnical Characteristics Figure 4.1 LSI40909G-S Components 4.1.2 Electrical Characteristics Under nor mal conditions, the LSI40909G-S maxim um power requirement i s :+5VD C , ± 5%, 1.0 A, and ov er the operating range 0 ° Ct o5 5 ° C. Under abnor mal conditions + 5 V current ma y be higher . The PCI PRSNT1/ and PRSNT2/ pins are ...

  • LSI 40909G-S - page 39

    Operational En vironment 4-3 The f ollowing par ameters define the storage and transit en vironment for the LSI40909G-S: • Storage T emperature: − 45 ° Ct o+8 5 ° C (dr y bulb) • Relative Humidity Range: 5% to 95% noncondensing 4.1.4 Electroma gnetic Compliance These boards minimize electromagnetic emissions , susceptibility , and the eff ...

  • LSI 40909G-S - page 40

    4-4 LSI40909G-S T echnical Characteristics 3.3 V v oltage regulator . The PCI + 3 V/+ 5 V pins are used to diff erentiate between a 5 V or a 3.3 V PCI signaling environment. 4.2.2 The FC Interface The LSI40909G-S Fibre Channel interf ace provides an optical connection to the FC link. The GBIC board uses an SCA connector and rail set which accepts a ...

  • LSI 40909G-S - page 41

    LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solaris A-1 3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 12 pc 12.938 pc 13.851 pc 48.583 pc 52.5 pc 34.5 pc 34.732 pc Appendix A Glossary of T erms and Abbre viations 8B/10B A data encoding scheme de veloped b y IBM, translating byte wide data to an encoded 10-bit f or mat. ANSI American Nation ...

  • LSI 40909G-S - page 42

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc A-2 Glossar y of T erms and Abbreviations Configuration Ref ers to the wa y a computer is setup; the combined hardware components (computer , monitor , keyboard, and peripheral de vices) that make up a computer system; or the softw are settings that allow the hardware c ...

  • LSI 40909G-S - page 43

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc Glossar y of T erms and Abbre viations A-3 FC-1 Middle le vel of the FC-PH standard, defining the 8B/10B encoding/decoding and transmission protocol. FC-2 Highest le v el of FC-PH, defining the rules for signaling protocol and describing transfer of the fr ame, sequenc ...

  • LSI 40909G-S - page 44

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc A-4 Glossar y of T erms and Abbreviations Host The computer system in which a SCSI host adapter is installed. It uses the SCSI host adapter to transf er information to and from devices attached to the SCSI bus . Host Adapter A circuit board or integrated circuit that pro ...

  • LSI 40909G-S - page 45

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc Glossar y of T erms and Abbre viations A-5 Operating System A program that organiz es the internal activities of the computer and its peripheral devices . An operating system performs basic tasks such as moving data to and from de vices, and managing inf or mation in mem ...

  • LSI 40909G-S - page 46

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc A-6 Glossar y of T erms and Abbreviations Responder An FC ter m ref erring to the answ ering device . RISC Core LSIFC909 chips contain a RISC (Reduced Instruction Set Computer) processor , programmed through microcode scripts. ROM Read Only Memor y . Memor y from which i ...

  • LSI 40909G-S - page 47

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc Glossar y of T erms and Abbre viations A-7 System BIOS Controls the low le vel POST (P ower-On Self-T est), and basic operation of the CPU and computer system. TID T arget ID . T opology The logical and/or physical arrangement of stations on a netw ork. ULP Upper La yer ...

  • LSI 40909G-S - page 48

    3.75 pc 10.25 pc 11.25 pc 38.25 pc 4.333 pc 48.583 pc 52.5 pc 34.5 pc 44.25 pc A-8 Glossar y of T erms and Abbreviations ...

  • LSI 40909G-S - page 49

    LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solaris Customer Feedbac k W e would appreciate y our f eedback on this document. Please cop y the f ollowing page , add your comments , and f ax it to us at the number shown. If appropriate, please also f ax copies of any marked-up pages from this document. Impor tant: Please include y our nam ...

  • LSI 40909G-S - page 50

    Customer F eedback Reader’ s Comments F ax your comments to: LSI Logic Cor poration T echnical Publications M/S E-198 F ax: 408.433.4333 Please tell us how y ou rate this document: LSI40909G-S PCI to Fibre Channel Host Adapter f or Sun Solaris User’ s Guide. Place a check mark in the appropriate blank f or each categor y . What could we do to i ...

  • LSI 40909G-S - page 51

    U .S. Distributor s by State A. E. A vnet Electronics http://www .hh.avnet.com B. M. Bell Microproducts, Inc. (for HAB’ s) http://www .bellmicro.com I. E. Insight Electronics http://www .insight-electronics.com W . E. W yle Electronics http://www .wyle.com Alabama Daphne I. E. T el: 334.626.6190 Huntsville A. E. T el: 256.837.8700 B. M. T el: 256 ...

  • LSI 40909G-S - page 52

    U .S. Distributor s by State (Continued) Montana A. E. T el: 800.526.1741 W . E. T el: 801.974.9953 Nebraska A. E. T el: 800.332.4375 W . E. T el: 303.457.9953 Nevada Las V egas A. E. T el: 800.528.8471 W . E. T el: 702.765.7117 New Hampshire A. E. T el: 800.272.9255 W . E. T el: 781.271.9953 New Jerse y Nor th/South A. E. T el: 201.515.1641 T el: ...

  • LSI 40909G-S - page 53

    Direct Sales Representatives by State (Components and Boards) E. A. Earle Associates E. L. Electrodyne - UT GRP Group 2000 I. S. Infinity Sales , Inc. ION ION Associates , Inc. R. A. Rathsburg Associ- ates, Inc. SGY Synergy Associates , Inc. Arizona T empe E. A. T el: 480.921.3305 California Calabasas I. S. T el: 818.880.6480 Irvine I. S. T el: 71 ...

  • LSI 40909G-S - page 54

    Sales Offices and Design Resource Center s LSI Logic Corporation Corporate Headquarters 1551 McCarthy Blvd Milpitas CA 95035 T el: 408.433.8000 Fax: 408.433.8989 NORTH AMERICA California Irvine 18301 V on Kar man A ve Suite 900 Irvine, CA 92612 ♦ T el: 949.809.4600 F ax: 949.809.4444 Pleasanton Design Center 5050 Hopy ard Road, 3rd Floor Suite 3 ...

  • LSI 40909G-S - page 55

    Sales Offices and Design Resource Center s (Continued) Korea Seoul LSI Logic Corporation of Korea Ltd 10th Fl., Haesung 1 Bldg. 942, Daechi-dong, Kangnam-ku, Seoul, 135-283 T el: 82.2.528.3400 F ax: 82.2.528.2250 The Netherlands Eindhov en LSI Logic Europe Ltd World T rade Center Eindhoven Building ‘Rijder’ Bogert 26 5612 LZ Eindhoven T el: 31 ...

  • LSI 40909G-S - page 56

    International Distributor s Australia New South W ales Reptechnic Pty Ltd 3/36 Bydown Street Neutral Bay , NSW 2089 ♦ T el: 612.9953.9844 F ax: 612.9953.9683 Belgium Acal n v/sa Lozenberg 4 1932 Zav entem T el: 32.2.7205983 F ax: 32.2.7251014 China Beijing LSI Logic International Services Inc. Beijing Representative Office Room 708 Canwa y Build ...

Fabricant LSI Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilLSI 40909G-S peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques LSI
- manuels d’utilisations 40909G-S
- fiches produit LSI
- dépliants
- ou étiquettes-énergie LSI 40909G-S
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation LSI 40909G-S.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation LSI 40909G-S, manuels d’entretien, brefs manuels ou manuels de l’utilisateur LSI 40909G-S. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit LSI 40909G-S.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil LSI 40909G-S, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser LSI 40909G-S par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs LSI 40909G-S.

Le manuel d’utilisation complet LSI, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel LSI 40909G-S - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières LSI 40909G-S, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLSI 40909G-S qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil LSI 40909G-S - qui devraient nous aider dans les premières étapes lors de l'utilisation LSI 40909G-S
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de LSI 40909G-S
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service LSI 40909G-S dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de LSI 40909G-S?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec LSI 40909G-S, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec LSI 40909G-S il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)