    359583-YTG-B-0208 TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2 - 5 TONS GENERAL All Models 1/2 - 5 tons ship as factory- charged packages. Horizontal units are design ed for suspended ceiling mount- ing. Horizontal models are sh ipped with ‘straight-thro ugh’ evap ...

  • York 359583-YTG-B-0208 - page 2

    359583-YTG-B-0208 2 Johnson Controls Unitary Products ELECTRICAL/CONTROLS All units are completely fact ory wire d with all necessar y operating controls. A 24 volt co ntrol circuit, with over- size transformer, is provid ed for field connection. Un its are designed to operate wit h conventio nal thermostat control inte rface. Th e reve rsing valve ...

  • York 359583-YTG-B-0208 - page 3

    3 5 9 5 8 3 - Y T G - B - 0 2 0 8 Johnson Controls Unitary Products 3 NOTE: 1. Performance calculated in accordance with ARI/ISO S t andard 13256-1 for W ater Loop Appl ication. 2. Cooling capacities are rat ed at entering air conditions o f 80.6ºF db / 66.2ºF wb. 86ºF entering water temperature. 3. Heating capacit i es are ra ted at entering ai ...

  • York 359583-YTG-B-0208 - page 4

    359583-YTG-B-0208 4 Johnson Controls Unitary Products NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 2: RP 007 @200 CFM NOMINAL AI RFLOW VERTICAL AND HORIZONTAL MODELS EWT (ºF) GPM WPD (PSI) Cooling EWT(ºF) GPM Heati ...

  • York 359583-YTG-B-0208 - page 5

    3 5 9 5 8 3 - Y T G - B - 0 2 0 8 Johnson Controls Unitary Products 5 NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 3: RP 009 @ 300 CFM NOMINAL AIR FLOW VERTICAL AND HORIZON T AL MODELS EWT (ºF) GPM WPD (PSI) Cooling ...

  • York 359583-YTG-B-0208 - page 6

    359583-YTG-B-0208 6 Johnson Controls Unitary Products NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 4: RP 012 @400 CFM NOMINAL AI RFLOW VERTICAL AND HORIZONTAL MODELS EWT (ºF) GPM WPD (PSI) Cooling EWT(ºF) GPM Heatin ...

  • York 359583-YTG-B-0208 - page 7

    3 5 9 5 8 3 - Y T G - B - 0 2 0 8 Johnson Controls Unitary Products 7 NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 5: RP 018 @ 600 CFM NOMINAL AIR FLOW VERTICAL AND HORIZON T AL MODELS EWT (ºF) GPM WPD (PSI) Cooling ...

  • York 359583-YTG-B-0208 - page 8

    359583-YTG-B-0208 8 Johnson Controls Unitary Products NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 6: RP 0024 @ 800 CFM NOMINAL AI RFLOW VERTICAL AND HORIZONTAL MODELS EWT (ºF) GPM WPD (PSI) Cooling EWT(ºF) GPM Heat ...

  • York 359583-YTG-B-0208 - page 9

    3 5 9 5 8 3 - Y T G - B - 0 2 0 8 Johnson Controls Unitary Products 9 NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 7: R P 030 @ 1000 CF M NOMINAL AI RFLOW VERT ICAL AND HORIZONTAL MODELS EWT (ºF) GPM WPD (PSI) Coolin ...

  • York 359583-YTG-B-0208 - page 10

    359583-YTG-B-0208 10 Johnson Controls Unitary Products NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 8: RP 036 @ 1200 CFM NOMINAL AIRFLOW VERTICAL AND HORIZONT AL MODELS EWT (ºF) GPM WPD (PSI) Cooling EWT (ºF) GPM He ...

  • York 359583-YTG-B-0208 - page 11

    3 5 9 5 8 3 - Y T G - B - 0 2 0 8 Johnson Controls Unitary Products 11 NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 9: R P 048 @ 1600 CF M NOMINAL AI RFLOW VERT ICAL AND HORIZONTAL MODELS EWT (ºF) GPM WPD (PSI) Cooli ...

  • York 359583-YTG-B-0208 - page 12

    359583-YTG-B-0208 12 Johnson Controls Unitary Products NOTE: All capacity data shown is NET - includes motor powe r/heat at design CFM and HI fan speed. Tabulated kW values do not include allowance for external pumping power. T ABLE 10: RP 060 @ 2000 CFM NOMINAL AI RFLOW VERTICAL AND HORIZONTAL MODELS EWT (ºF) GPM WPD (PSI) Cooling EWT(ºF) GPM He ...

  • York 359583-YTG-B-0208 - page 13

    3 5 9 5 8 3 - Y T G - B - 0 2 0 8 Johnson Controls Unitary Products 13 Units are shipped pre-wired for Medium speed. All airflow ratings are at lowest voltage rat ing of dual rating (i.e.2 08 volt). Airflow ratings include resistance of wet coil and clean air filters. T ABLE 1 1: BLOWER PERFORMANCE EXTERNAL STATIC PRESSURE (IN W .G.) Unit Speed 0 0 ...

  • York 359583-YTG-B-0208 - page 14

    359583-YTG-B-0208 14 Johnson Controls Unitary Products FIGURE 1 - HORIZONT AL DIMENSIONAL DA T A 1 - Electrical Box Service Door 2 - Compressor and Condenser Service Door 3 - Blower Service Door SERVICE DOORS MODEL RETURN AIR DIMENSIONS IN INCHES ...

  • York 359583-YTG-B-0208 - page 15

    3 5 9 5 8 3 - Y T G - B - 0 2 0 8 Johnson Controls Unitary Products 15 FIGURE 2 - VERTICAL DIMENSIONAL DATA SERVICE DOORS 1 - ELECTRICAL BOX SERVICE DOOR 2 - COMPRESSOR AND CONDENSER SERVICE DOOR 3 - BLOWER SERVICE DOOR ...

  • York 359583-YTG-B-0208 - page 16

    Subject to change without notice. Print ed in U.S.A. 359583-YTG-B-0208 Copyright © 2008 by Johnson Controls, In c. All rights reserved. Supersedes: 359583 /036-21486-001-A-110 2 Johnson Cont rols Unitary Pr oducts 5005 York Drive Norman, OK 73069 ...

Fabricant York Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilYork 359583-YTG-B-0208 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques York
- manuels d’utilisations 359583-YTG-B-0208
- fiches produit York
- dépliants
- ou étiquettes-énergie York 359583-YTG-B-0208
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation York 359583-YTG-B-0208.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation York 359583-YTG-B-0208, manuels d’entretien, brefs manuels ou manuels de l’utilisateur York 359583-YTG-B-0208. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit York 359583-YTG-B-0208.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil York 359583-YTG-B-0208, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser York 359583-YTG-B-0208 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs York 359583-YTG-B-0208.

Le manuel d’utilisation complet York, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel York 359583-YTG-B-0208 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières York 359583-YTG-B-0208, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lYork 359583-YTG-B-0208 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil York 359583-YTG-B-0208 - qui devraient nous aider dans les premières étapes lors de l'utilisation York 359583-YTG-B-0208
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de York 359583-YTG-B-0208
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service York 359583-YTG-B-0208 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de York 359583-YTG-B-0208?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec York 359583-YTG-B-0208, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec York 359583-YTG-B-0208 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)