Manuel d’utilisation Weil-McLain CGa

24 pages 2.63 mb
Télécharger

Aller à la page of 24

Summary
  • Weil-McLain CGa - page 1

    Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance . • Do not touch any electrical switch ; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’ s phone . Follow the gas sup ...

  • Weil-McLain CGa - page 2

    2 Part Number 550-1 10-592/1099 Please read this page first How to use this manual . . . The User ’ s Infor mation Manual pro vides information to the boiler o w ner/user for r outine operation and maintenance and emergency shutdown. Detailed information on boiler installation, operation, start-up, service and parts is included in the Boiler Manu ...

  • Weil-McLain CGa - page 3

    3 Part Number 550-1 10-592/1099 F ailure t o adher e to the guidelines on this pag e can result in sev ere personal injury , death or substantial property damage. STOP!! — Read befor e proceeding Products to avoid Spray cans containing chloro/fluorocar- bons Permanent wave solutions Chlorinated waxes/cleaners Chlorine-based swimming pool chemical ...

  • Weil-McLain CGa - page 4

    4 Part Number 550-1 10-592/1099 5921 0 Boiler components 5921 1 1 Gas valve 2 Pilot burner 3 Main burner 4 Gas manifold/orifices 5 Control module 6 Inducer (CGi and CGs only) 7 V ent damper (CGa only) 8 W ater temperature limit switch 9 T ransformer 10 Spill switc h (CGa only) 11 Air pressure switc h (CGi and CGs only) 12 Rollout thermal fuse eleme ...

  • Weil-McLain CGa - page 5

    5 Part Number 550-1 10-592/1099 1 Gas valve 2 Pilot burner 3 Main burner 4 Gas manifold/orifices 5 Control module 7 V ent damper 9 T ransformer 10 Spill switc h 12 Rollout thermal fuse element 13 Low water cutoff (steam boilers) 14 Limit control(s) 15 Draft hood 16 Circulator 18 Gauge (pressure or pressure/temperature) 19 Gauge glass (steam only) ...

  • Weil-McLain CGa - page 6

    6 Part Number 550-1 10-592/1099 Maintain boiler using schedule below T ankless water heater (EG and EGH only) If boiler is used to supply d omestic hot water , limit co ntrol should be set to suppl y adequate hot water . W eil-M cLain tankless heaters are rated at 200 ° F boile r water t emperature. T o ge t rated output, set low limit at 200 ° F ...

  • Weil-McLain CGa - page 7

    7 Part Number 550-1 10-592/1099 User maintenance pr ocedur es Do not attempt to place boiler in operation if spill switch cuts of f gas flow . Immediately call a serv ice technician. Failure to do so can cause severe personal injury , death or substantial pr oper t y damage. Rollout thermal fuse element CGa, CGi, CGs, EG, EGH, PEG & PFG-5 only ...

  • Weil-McLain CGa - page 8

    8 Part Number 550-1 10-592/1099 ❏ Check daily . . . . . . . . . . . . . . . . . Air openings 1. V er ify that combustion and v entilation air openings to the boiler room and/or building are open and unobstructed. 2. CGs boilers — V erify that b oiler vent disc harge and air intake are clean and free of obstructions. Remove any debris on the air ...

  • Weil-McLain CGa - page 9

    9 Part Number 550-1 10-592/1099 Figure 4 Automatic air vent Automatic air vents (if used) 1. See Figure 4 . 2 . Remove the cap from any automatic air vent in the system and check operation by depressing valve B slightly with the tip of a screwdriv er . 3. If the air vent valve appears to be working freely and not leaking , replace cap A , twisting ...

  • Weil-McLain CGa - page 10

    10 Part Number 550-1 10-592/1099 Probe type— See Figure 8 1 . Clean probe type low water cutoff for proper operation. a. T ur n off power to boiler and wait 5 min utes. b . Drain water to bottom of gauge glass. c. T urn on po wer . d. Set thermostat to call for heat. Red neon lamp on lower water cutoff should light. e. W ait 5 minutes. Boiler sho ...

  • Weil-McLain CGa - page 11

    11 Part Number 550-1 10-592/1099 Operate boiler relief valve ❏ Service every 6 months . . . . . . . . . To av oid water damage or scalding due to valve operation, a metal discharge line must be connected to relief valve outlet and run to a safe place of disposal. This discharge line must be installed by a qualified heating installer or service te ...

  • Weil-McLain CGa - page 12

    12 Part Number 550-1 10-592/1099 Follow boiler shutdown procedure ❏ End-of-season shutdo wn . . . . . . . . 1. Follow “ T O TURN OFF GA S T O APPLIANCE ” on the Lighting/Operating instr uctions on the inside of the jacket panel. Y ou will also find these instructions on pages 13 through 22 of this manual. U se the Lighting/Operating instr uct ...

  • Weil-McLain CGa - page 13

    13 Part Number 550-1 10-592/1099 Lighting instructions FOR Y OUR S AFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS T O TURN OFF GAS T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the g ...

  • Weil-McLain CGa - page 14

    14 Part Number 550-1 10-592/1099 • Gas valve — Robertshaw 7200 FOR Y OUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS T O TURN OFF GAS T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. F ...

  • Weil-McLain CGa - page 15

    15 Part Number 550-1 10-592/1099 FOR Y OUR S AFETY READ BEFORE LIGHTING OPERA TING INS TRUCTIONS T O TURN OFF GAS T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s i ...

  • Weil-McLain CGa - page 16

    16 Part Number 550-1 10-592/1099 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GAS T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain CGa - page 17

    17 Part Number 550-1 10-592/1099 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GAS T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain CGa - page 18

    18 Part Number 550-1 10-592/1099 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GAS T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain CGa - page 19

    19 Part Number 550-1 10-592/1099 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GAS T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain CGa - page 20

    20 Part Number 550-1 10-592/1099 FOR Y OUR SAFETY READ BEFORE LIGHTING OPERA TING INS TRUCTIONS T O TURN OFF GAS T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s i ...

  • Weil-McLain CGa - page 21

    21 Part Number 550-1 10-592/1099 FOR YOUR SAFETY READ BEFORE OPERA TING OPERA TING INSTRUCTIONS TO TURN OFF GAS TO THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instr ...

  • Weil-McLain CGa - page 22

    22 Part Number 550-1 10-592/1099 ANNUAL SHUTDOWN PROCEDURE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach y our gas supplier , call the fire de ...

  • Weil-McLain CGa - page 23

    23 Part Number 550-1 10-592/1099 Common pr oblems and solutions Symptom Common Causes Possible Corrections Rapid cycling — boiler turns on and off frequently Thermostat installed where drafts or heat affect reading Locate thermostat on inner wall away from heat sources or cool drafts. Heat anticipator in thermostat adjusted incorrectly Adjust the ...

  • Weil-McLain CGa - page 24

    24 Part No. 550-1 10-592/1099 W eil-McLain Limited W arranty for Residential & Commercial Cast Iron Boilers W eil-McLain 500 Blaine Street Michigan City , IN 46360-2388 http://www .weil-mclain.com RESIDENTIAL W A TER W ARRANTY—Limited Lifetime RESIDENTIAL STEAM W ARRANTY—Limited 10 Y ear COMMERCIAL W ARRANTY—Limited 10-Y ear NOTE: The res ...

Fabricant Weil-McLain Catégorie Boiler

Les documents que nous recevons du fabricant de l'appareilWeil-McLain CGa peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Weil-McLain
- manuels d’utilisations CGa
- fiches produit Weil-McLain
- dépliants
- ou étiquettes-énergie Weil-McLain CGa
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Weil-McLain CGa.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Weil-McLain CGa, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Weil-McLain CGa. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Weil-McLain CGa.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Weil-McLain CGa, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Weil-McLain CGa par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Weil-McLain CGa.

Le manuel d’utilisation complet Weil-McLain, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Weil-McLain CGa - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Weil-McLain CGa, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lWeil-McLain CGa qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Weil-McLain CGa - qui devraient nous aider dans les premières étapes lors de l'utilisation Weil-McLain CGa
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Weil-McLain CGa
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Weil-McLain CGa dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Weil-McLain CGa?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Weil-McLain CGa, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Weil-McLain CGa il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)