  • Graco Husky 224-833 - page 1

    308–230 Rev . J Supersedes Rev H and PCN J First choice when quality counts.   Model 224–833 Shown (Pail is not included) INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Husky  307 Air Spray/HVLP Systems ST AINLESS STEEL FLUID FITTINGS, ACET AL PUMP ...

  • Graco Husky 224-833 - page 2

      T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts 12 . . . . . . . . . . . . . . . . . . ...

  • Graco Husky 224-833 - page 3

      TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.  Know the specific hazards of the fluid you are using.  Store hazardous fluid in an approved container . Dispose of hazardous fluid according to all local, state and natio ...

  • Graco Husky 224-833 - page 4

    4 308-230 Installation Assembling Pail Mount Units 1. Insert the suction tube (27) into the elbow (15) to its full depth. T ighten the nut securely . See Fig. 1. 2. Insert the recirculation tube (28) into the connector (16) to its full depth. T ighten the nut securely . 3. On Models 236–870 and 224–833, assemble the Fluid Regulator Kit (items 1 ...

  • Graco Husky 224-833 - page 5

    308-230 5 Installation Assembling the W all Mount Unit Install the wall bracket (2) 5 ft (1.52 m) above the floor . Use the mounting hole layout shown on page 18. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation. The following steps apply to Model 236–41 ...

  • Graco Husky 224-833 - page 6

    6 308-230 Installation General Information 1. The T ypical Installations shown on pages 7 and 8 are only a guide for selecting and installing sys - tem components. Contact your Graco distributor or Graco T echnical Assistance (see back page) for assistance in planning a system to suit your needs. 2. Always use Genuine Graco Parts and Accesso - ries ...

  • Graco Husky 224-833 - page 7

    308-230 7 Installation 04966 04967 Fig. 3 F KEY A Husky 307 Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Air Line Quick Disconnect E Master Air V alve (for accessories) F Air Line Filter G Gun Air Regulator H Pump Air Regulator J Fluid Drain V alve (required) K Fluid Recirculation Line L Fluid Suction Line M Surge T ...

  • Graco Husky 224-833 - page 8

      Installation 04973 Fig. 4 KEY A Husky 307 Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Air Line Quick Disconnect E Master Air V alve (for accessories) F Air Line Filter G Gun Air Regulator H Pump Air Regulator J Fluid Drain V alve (required) L Fluid Suction Line M Surge T ank and Filter N Gu ...

  • Graco Husky 224-833 - page 9

      Installation Grounding FIRE AND EXPLOSION HAZARD This pump must be grounded. Before operating the pump, ground the system as explained below . Also read the sec - tion FIRE OR EXPLOSION HAZARD on page 3. W ARNING T o reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping ...

  • Graco Husky 224-833 - page 10

    10 308-230 Operation Pressure Relief Procedure PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci - dentally . T o reduce the risk of an injury from acci - dental spray from the gun, splashing fluid, or mov - ing parts, follow the Pressure Relief Procedure whenever you: ? ...

  • Graco Husky 224-833 - page 11

    308-230 11 Operation Pump Shutdown W ARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10. At the end of the work shift, relieve the pressure. Flushing and Storage W ARNING To reduce the risk of serious injury whenever you are instructed to relieve pressu ...

  • Graco Husky 224-833 - page 12

    12 308-230 Parts Model 236–412, Series A Includes items 1–42 Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 D31–331 PUMP , Husky 307; SST/ r ; See 308–553 for parts 1 2 235–505 COVER, pail; stainless steel 1 3 1 1 1–276 THUMBSCREW ; 5/16–18 unc; 1” (25.4 mm) long; sst 3 4 104–1 19 SCREW , cap, hex hd; 1/4–20 ...

  • Graco Husky 224-833 - page 13

    Model 236–412, Series A Includes items 1–42 1 2 8 14 15 16 20 21 22 Part of item 1 11 Apply thread sealant to male threads. Ref. No. 38, Hose Kit, Includes Items 39–41. 7 10 12 13 14 17 18 19 23 24 25 26 26 29 30 4 5 6 27 39 40 41 A A 3 Pail is not included. Part of item 17 17a 17b 1 3 4 2 T orque to 35–55 in–lb (4.0–6.2 N.m). Do not ov ...

  • Graco Husky 224-833 - page 14

    14 308-230 Parts Model 236–870, Series A Includes items 1–35 and 42 Model 224–833, Series B Includes items 1–42 Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 D31–331 PUMP , Husky 307; SST/ r ; See 308–553 for parts 1 2 235–505 COVER, pail; stainless steel 1 3 1 1 1–276 THUMBSCREW ; 5/16–18 unc; 1” (25.4 mm) ...

  • Graco Husky 224-833 - page 15

    Model 236–870, Series A Includes items 1–35 and 42 Model 224–833, Series B Includes items 1–42 Apply thread sealant to male threads. Pail is not included. 1 3 4 2 T orque to 35–55 in–lb (4.0–6.2 N.m). Do not over-torque. T orque to contact plus 1/2 turn. Insert tube into elbow (14) to full depth and tighten nut securely with wrench. I ...

  • Graco Husky 224-833 - page 16

    16 308-230 Parts Model 236–628, Series A Includes items 1–26 and 34–42 Model 236–868, Series A Includes items 1–26, 34–37, and 42 Model 236–869, Series A Includes items 1–37 and 42 Model 236–414, Series A Includes items 1–42 Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 D31–331 PUMP , Husky 307; SST/ r ; ...

  • Graco Husky 224-833 - page 17

    Model 236–628, Series A Includes items 1–26 and 34–42 Model 236–868, Series A Includes items 1–26, 34–37, and 42 Model 236–869, Series A Includes items 1–37 and 42 Model 236–414, Series A Includes items 1–42 1 14 20 21 22 Part of item 1 11 Apply thread sealant to male threads. Ref. No. 38, Hose Kit, Includes Items 39–41. 7 10 ...

  • Graco Husky 224-833 - page 18

    18 308-230 Dimensions Pail is not included. Maximum pail outer diameter is 12.125 in. (308 mm).   13.1 in. (332.7 mm) 15.1 in. (383.5 mm) Pail is not included. Maximum pail outer diameter is 12.125 in. (308 mm). 13.1 in. (332.7 mm) Model 236–412 Models 236–870 and 224–833 17.5 in. (444.5 mm) W all Mounting Hole L ...

  • Graco Husky 224-833 - page 19

    308-230 19 T echnical Data Wetted Parts Pump See 308–553 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pail Cover (236–870, 224–833, 236–412) stainless steel . . . . . . . . . . . . . . . . . . . . . . . . . . . Fluid Hoses nylon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hose Couplings stainless ...

  • Graco Husky 224-833 - page 20

      The Graco W arranty and Disclaimers Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special extend ...

Fabricant Graco Catégorie Paint Sprayer

Les documents que nous recevons du fabricant de l'appareilGraco Husky 224-833 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Graco
- manuels d’utilisations Husky 224-833
- fiches produit Graco
- dépliants
- ou étiquettes-énergie Graco Husky 224-833
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Graco Husky 224-833.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Graco Husky 224-833, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Graco Husky 224-833. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Graco Husky 224-833.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Graco Husky 224-833, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Graco Husky 224-833 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Graco Husky 224-833.

Le manuel d’utilisation complet Graco, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Graco Husky 224-833 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Graco Husky 224-833, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGraco Husky 224-833 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Graco Husky 224-833 - qui devraient nous aider dans les premières étapes lors de l'utilisation Graco Husky 224-833
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Graco Husky 224-833
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Graco Husky 224-833 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Graco Husky 224-833?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Graco Husky 224-833, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Graco Husky 224-833 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image