    ¤ • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • OUTBA CK 145 ™ OPERA TOR’S MANUAL IM973 April, 2009 Safety Depends on You Lincoln arc welding and cutting ...

  • Lincoln Electric 145 - page 2

    ¤ FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. _____________________________________________ ...

  • Lincoln Electric 145 - page 3

    ¤ ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Us e suitable clothing made from durable flame-resistant material to protect your ...

  • Lincoln Electric 145 - page 4

    ¤ iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. Nat ...

  • Lincoln Electric 145 - page 5

    ¤ iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuit ...

  • Lincoln Electric 145 - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric 145 - page 7

    vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .......................................................................................................A-1 Safety Precautions. ......................... ...

  • Lincoln Electric 145 - page 8

    A-1 INST ALLA TION OUTBACK™ 145 A-1 ¤ TECHNICAL SPECIFICA TIONS - OUTBACK™ 145 (K2707-1) Make/Model Description Speed (RPM) Displacement Ignition Capacities System SUBARU 1 cylinder 3750RPM High Idle 17.07 cu. in Electric & Recoil Fuel: 6.86 gal. ROBIN 4 cycle (287 cc) Start; (24.9L) EX30 air-cooled 3400RPM Full Load OHC gasoline Bore x St ...

  • Lincoln Electric 145 - page 9

    A-2 INST ALLA TION OUTBACK™ 145 A-2 ¤ ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet cloth- ing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. W ARNING ENGINE EXHAUST can kill. • Use in open, well ventilated areas or vent exhaust outside. • Do not stack any ...

  • Lincoln Electric 145 - page 10

    A-3 INST ALLA TION OUTBACK™ 145 A-3 ¤ CAUTION SP ARK ARRESTER Some federal, state or local laws may require gaso- line engines to be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this machine does not qualify as a spark arres ...

  • Lincoln Electric 145 - page 11

    A-4 INST ALLA TION OUTBACK™ 145 A-4 ¤ ELECTRICAL OUTPUT CONNECTIONS See Figure A.1 for the location of the current control dial, weld output terminals, ground stud, circuit break- ers, 240 and 120 volt receptacles. WELDING CABLE CONNECTIONS Cable Size and Length Be sure to use welding cables that are large enough. The correct size and length bec ...

  • Lincoln Electric 145 - page 12

    A-5 INST ALLA TION OUTBACK™ 145 A-5 ¤ MACHINE GROUNDING Because this portable engine driven welder or genera- tor creates its own power, it is not necessary to con- nect its frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.). To prevent dangerous electric shock, other equipment to which this engi ...

  • Lincoln Electric 145 - page 13

    A-6 INST ALLA TION OUTBACK™ 145 A-6 ¤ PREMISES WIRING The OUTBACK™ 145 is not recommended for premises wiring. The OUTBACK™ 145 does not have a combined 120/240 volt receptacle and cannot be connected to a premises. The OUTBACK™ 145 is intended only for backup intermittent power. Certain electrical devices cannot be provided by the OUTBACK ...

  • Lincoln Electric 145 - page 14

    A-7 INST ALLA TION OUTBACK™ 145 A-7 ¤ CAUTION Certain Electrical devices cannot be powered by the OUTBACK™ 145. See Table A.2 TABLE A.2 ELECTRICAL DEVICE USE WITH THE OUTBACK™ 145 Type Resistive Capacitive Inductive Capacitive / Inductive Common Electrical Devices Heaters, toasters, incandescent light bulbs, electric range, hot pan, skillet, ...

  • Lincoln Electric 145 - page 15

    B-1 OPERA TION OUTBACK™ 145 B-1 ¤ SAFETY INSTRUCTIONS Observe additional Safety Guidelines detailed throughout this manual. W ARNING W ARNING ENGINE EXHAUST can kill. • Use in open, well ventilated areas or vent exhaust outside. • Do not stack anything on or near the engine. MOVING PARTS can injure. • Do not operate with doors open or guar ...

  • Lincoln Electric 145 - page 16

    B-2 OPERA TION B-2 OUTBACK™ 145 ¤ GRAPHIC SYMBOLS USED ON THIS EQUIPMENT OR IN THIS MANUAL W ARNING / CAUTION CHOKE OIL FUEL AIR CLEANER CIRCUIT BREAKER GROUND (AUXILIAR Y POWER) WORK CLAMP ELECTRODE WELDING ARC ...

  • Lincoln Electric 145 - page 17

    B-3 OPERA TION B-3 OUTBACK™ 145 ¤ GENERAL DESCRIPTION The OUTBACK™ 145 is designed for commercial use welder/generator applications. As a welder it provides 145 amps of DC constant current for welding with DC stick electrodes. A single dial lets you select a full range of welding output from 50 to 145 amps. As a generator it can supply up to s ...

  • Lincoln Electric 145 - page 18

    1 2 7 8 3 or 4 6 5 B-4 OPERA TION B-4 OUTBACK™ 145 ¤ CONTROLS AND SETTINGS All welder/generator controls are located on the Output Control Panel. Gasoline engine controls are mounted on the engine. See Figure B.1 and the figures in engine operation section. WELDER/GENERA TOR CONTROLS See Figure B.1 for the location of the following features: 1. ...

  • Lincoln Electric 145 - page 19

    B-5 OPERA TION B-5 OUTBACK™ 145 ¤ ENGINE OPERA TION Starting/Shutdown Instructions Be sure all Pre-Operation Engine Service has been performed. Also, Read owners manual before starting for the first time. (See INSTALLATION section) NOTE: Remove all loads connected to the AC power receptacles before starting the gasoline engine. Put the “ON/OFF ...

  • Lincoln Electric 145 - page 20

    B-6 OPERA TION B-6 OUTBACK™ 145 ¤ 4. Insert the electrode into the electrode hold er. 5. Set the current control dial to the desired output current . 6. Start the gasoline engine. See ENGINE OPERATION in this section of the manual. 7. Strike an arc and begin welding. AFTER YOU FINISH THE WELD: 1. Stop the gasoline engine. See ENGINE OPERA- TION ...

  • Lincoln Electric 145 - page 21

    B-7 OPERA TION B-7 OUTBACK™ 145 ¤ TABLE B.2 ELECTRODE SELECTION GUIDE 120V Receptacle Operation: • Set the Output Control on the Pro-Cut 25 no higher than the 15 amp position.( Higher settings may cause circuit breaker on the OUTBACK™ 145 to trip.) • Maximum material thickness that can be cut is 1/4". 240V Receptacle Operation: • Th ...

  • Lincoln Electric 145 - page 22

    B-8 OPERA TION B-8 OUTBACK™ 145 ¤ TABLE B.3 AUXILIARY POWER APPLICATIONS Suggested Power Applications Running Watts *Start-up Watts (Continuous) (Peak) *Air Compressor - 1 HP 2,000 4,000 - 8,000 *Air Compressor - 3/4 HP 1,250 3,100 - 5,000 *Airless Sprayer - 1/3 HP 600 1,500 - 2,400 Chain Saw 1,200 Circular Saw 1,200 Coffee Maker 1,000 *Deep Fre ...

  • Lincoln Electric 145 - page 23

    C-1 ACCESSORIES C-1 OUTBACK™ 145 ¤ OPTIONS/ACCESSORIES The following options/accessories are available for your OUTBACK™145 from your local Lincoln Distributor: ACCESSORY KIT (K875) – Includes the following: • Twenty feet (6.1 meters) of #6 AWG electrode cable with lug. • Fifteen feet (4.6 meters) of #6 work cable with lugs. • Work Cla ...

  • Lincoln Electric 145 - page 24

    D-1 MAINTENANCE D-1 OUTBACK™ 145 ¤ SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • Turn the engine off before working inside the machine. • Remove guards only when necessary to perform maintenance and replace them when the mainte- nance requiring their removal is complete. • If guards are miss ...

  • Lincoln Electric 145 - page 25

    D-2 MAINTENANCE D-2 OUTBACK™ 145 ¤ To service the pre-cleaner : Remove the cover. Carefully remove the foam pre- cleaner from the filter element. 1. Wash in liquid detergent and water. 2. Squeeze dry in a clean cloth. 3. Saturate in clean engine oil. 4. Squeeze in a clean, absorbent cloth to remove all excess oil. Carefully place the pre-cleaner ...

  • Lincoln Electric 145 - page 26

    ¤ E-1 TROUBLESHOOTING OUTBACK™ 145 E-1 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repai ...

  • Lincoln Electric 145 - page 27

    E-2 TROUBLESHOOTING E-2 OUTBACK™ 145 ¤ Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBL ...

  • Lincoln Electric 145 - page 28

    E-3 TROUBLESHOOTING E-3 OUTBACK™ 145 ¤ Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBL ...

  • Lincoln Electric 145 - page 29

    F-1 DIAGRAMS F-1 OUTBACK™ 145 ¤ L13929 W IRI NG DIA G RA M - OUTBA CK 145 _ WORK 6 5 3 CB1 20A J6 9 7 + - ROTO R FIELD SLIP RINGS W2 W1 CB1 20A 6A 6B GND-F 3B 3A GND-D 3 GND-C GROUND STUD ON CONTROL PANEL F RONT GND-E _ + D1 WORK GND-H GND-C 5 5A 5A 5B 5B NEUTRAL STUD ON CONTROL PANEL BOTTOM GND GND 6A SUPPRESSOR ASSEMBLY 204 MODULE LOW OIL SWIT ...

  • Lincoln Electric 145 - page 30

    F-2 DIMENSION PRINT F-2 OUTBACK™ 145 ¤ M21768 A.0 2 6.75 29.00 31.47 NOTES: N.A. CENTER OF GRAVIT Y W ITH OIL IN EN GINE AND EMPTY FUEL TANK. N.A. 25.62 21.60 7.79 13.50 8.25 ...

  • Lincoln Electric 145 - page 31

    NOTES OUTBACK™ 145 ¤ ...

  • Lincoln Electric 145 - page 32

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA EL ...

  • Lincoln Electric 145 - page 33

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes fro ...

  • Lincoln Electric 145 - page 34

    ¤ • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabricant Lincoln Electric Catégorie Welding System

Les documents que nous recevons du fabricant de l'appareilLincoln Electric 145 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lincoln Electric
- manuels d’utilisations 145
- fiches produit Lincoln Electric
- dépliants
- ou étiquettes-énergie Lincoln Electric 145
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lincoln Electric 145.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lincoln Electric 145, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lincoln Electric 145. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lincoln Electric 145.

Manuel d’utilisation complet de l’appareil Lincoln Electric 145, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lincoln Electric 145 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lincoln Electric 145.

Le manuel d’utilisation complet Lincoln Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lincoln Electric 145 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lincoln Electric 145, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLincoln Electric 145 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lincoln Electric 145 - qui devraient nous aider dans les premières étapes lors de l'utilisation Lincoln Electric 145
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lincoln Electric 145
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lincoln Electric 145 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lincoln Electric 145?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lincoln Electric 145, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lincoln Electric 145 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)