    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • PO WER W A VE A C/DC 1000 OPERA TOR’S MANUAL IM848-A June, 2009 Safety Depends on You Lincoln arc welding and ...

  • Lincoln Electric POWER WAVE 11124 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric POWER WAVE 11124 - page 3

    ii SAFETY ii ARC R A Y S can bur n. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4. b. Use suitable clothing made from durable flame-resistant material to protect your ...

  • Lincoln Electric POWER WAVE 11124 - page 4

    iii SAFETY iii FOR ELECTRIC ALL Y pow er ed equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 .b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. N ...

  • Lincoln Electric POWER WAVE 11124 - page 5

    iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits ? ...

  • Lincoln Electric POWER WAVE 11124 - page 6

    v SAFETY v ...

  • Lincoln Electric POWER WAVE 11124 - page 7

    vi SAFETY vi ...

  • Lincoln Electric POWER WAVE 11124 - page 8

    vii vii T T h h a a n n k k Y Y o o u u for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it hand ...

  • Lincoln Electric POWER WAVE 11124 - page 9

    viii viii T ABLE OF CONTENTS Page I nstallation .......................................................................................................................... Section A Specifications .......................................................................................................................A-1 Safety Precautions. ........... ...

  • Lincoln Electric POWER WAVE 11124 - page 10

    ix T ABLE OF CONTENTS ix Troubleshooting ..............................................................................................Section E How to Use Troubleshooting Guide .......................................................................E-1 Troubleshooting Guide...........................................................................E ...

  • Lincoln Electric POWER WAVE 11124 - page 11

    A-1 SPECIFICA TIONS POWER WAVE® AC/DC 1000 A-1 TECHNICAL SPECIFICA TIONS - POWER W A VE® AC/DC 1000 (K2344-1, K2344-2) OUTPUT RECOMMENDED INPUT WIRE AND FUSE SIZES 1 PHYSICAL DIMENSIONS TEMPERA TURE RANGES INPUT A T RA TED OUTPUT - THREE PHASE ONL Y INPUT VOLTS 3 PHASE 50/60 Hz 380 400 460 500 575 OPEN CIRCUIT VOLTAGE 25 to 100 V RMS 3 PHASE INPU ...

  • Lincoln Electric POWER WAVE 11124 - page 12

    LIFTING Lift the machine by the lift bail only. The lift bail is designed to lift the power source only. Do not attempt to lift the Power Wave AC/DC 1000 with accessories attached to it. ENVIRONMENT AL LIMIT A TIONS Do not use the Power Wave AC/DC 1000 in an out- door environment. The Power Wave AC/DC 1000 power source should not be subjected to fa ...

  • Lincoln Electric POWER WAVE 11124 - page 13

    INPUT AND GROUND CONNECTIONS MACHINE GROUNDING The frame of the welder must be grounded. A ground terminal marked with the symbol shown is located inside the reconnect / input access door for this pur- pose. See your local and national electrical codes for proper grounding methods. A-3 INST ALLA TION POWER WAVE® AC/DC 1000 A-3 I NPUT FUSE AND SUPP ...

  • Lincoln Electric POWER WAVE 11124 - page 14

    A-4 INST ALLA TION POWER WAVE® AC/DC 1000 A-4 SYSTEM CONNECTION System Overview The Power Wave AC/DC 1000 power source is designed to be a part of a modular welding system typically controlled by a Power Feed 10A Controller or customer supplied Programmable Logic Controller (PLC) . Each welding arc may be driven by a s ingle power source or by a n ...

  • Lincoln Electric POWER WAVE 11124 - page 15

    A-5 INST ALLA TION A-5 RECOMMENDED EQUIPMENT System Identifier Power Source Weld Cables Head Torch Power Source to Head Control Cable User Interface ArcLink Digital Communication Cable PLC (w/ User Interface) DeviceNet Cables and Accessories System Interface System Interface to Power Source Control Cable Part No . K2344-1 -or- K2344-2 K2163-xx -or- ...

  • Lincoln Electric POWER WAVE 11124 - page 16

    A-6 INST ALLA TION POWER WAVE® AC/DC 1000 A-6 OPTIONAL EQUIPMENT System Identifier Ethernet Network Equipment Personal Computer Travel Carriage Travel Carriage (High Capacity) Controller Mounting Bracket User Interface Horizontal Adjuster Vertical Adjuster Wire Reel Mounting (single) Wire Reel Mounting (dual) Mounting for Dual Head Flux Hopper Flu ...

  • Lincoln Electric POWER WAVE 11124 - page 17

    A-7 INST ALLA TION POWER WAVE® AC/DC 1000 A-7 Wi re Feeder (14 Pin) A rc lin k (5 Pin) Arclink Conn ect io n K 236 2-1 Wire Reel and Mou nt ing Wor k Piece K 231- XXX Head * Wor k Cable(s) * Electr od e Ca ble(s) K1785-XX W ire Feeder Control Ca ble K1 543-XX Arc li n k Co ntrol Cabl e Wor k Sense Lead (21) Electrode Sens e Lead (67) 67 Lead 21 Le ...

  • Lincoln Electric POWER WAVE 11124 - page 18

    A-8 INST ALLA TION POWER WAVE® AC/DC 1000 A-8 STEP BY STEP INST ALLA TION CHECKLIST SINGLE ARC SYSTEM CHECKLIST – (PF-10A CONTROLLED, 1 POWER SOURCE) (as shown in the Connection Diagram "Typical Single Arc System") Place Power Wave in suitable operating location. Mount PF10A Controller. Install PF10S Wire Drive and other accessories in ...

  • Lincoln Electric POWER WAVE 11124 - page 19

    A-9 INST ALLA TION POWER WAVE® AC/DC 1000 A-9 A A R R C C 2 2 A A R R C C 1 1 A A R R C C 1 1 A A R R C C 2 2 A A R R C C 1 1 A A R R C C 2 2 A A R R C C 1 1 A A R R C C 2 2 S S Y Y S S T T E E M M I I N N T T E E R R F F A A C C E E Ma st er In pu t ( S 12) Conn ects to Sys te m In t erface Arc lin k Co nnec tion 21 Le ad 67 Le ad * Wor k Cables ...

  • Lincoln Electric POWER WAVE 11124 - page 20

    A-10 INST ALLA TION POWER WAVE® AC/DC 1000 A-10 STEP BY STEP INST ALLA TION CHECKLIST TANDEM ARC SYSTEM CHECKLIST – (PF-10A CONTROLLED, 1 POWER SOURCE PER ARC) (as shown in the Connection Diagram "Typical Tandem Arc System”) Place Power Waves in suitable operating location. Mount PF10A Controllers. Install PF10S Wire Drives and other acce ...

  • Lincoln Electric POWER WAVE 11124 - page 21

    A-11 INST ALLA TION POWER WAVE® AC/DC 1000 A-11 A A R R C C 1 1 A A R R C C 2 2 A A R R C C 2 2 A A R R C C 3 3 A A R R C C 1 1 A A R R C C 3 3 A A R R C C 1 1 A A R R C C 2 2 A A R R C C 3 3 S S Y Y S S T T E E M M I I N N T T E E R R F F A A C C E E Connection Diagram- Typical Triple Arc System (DeviceNet PLC Controller) 67 Lead 21 Lead 14 P in ...

  • Lincoln Electric POWER WAVE 11124 - page 22

    A-12 INST ALLA TION POWER WAVE® AC/DC 1000 A-12 STEP BY STEP INST ALLA TION CHECKLIST TRIPLE ARC SYSTEM CHECKLIST – (DEVICENET PLC CONTROLLED, 1 POWER SOURCE PER ARC) (as shown in the Connection Diagram "Typical Triple Arc System”) Place Power Waves in suitable operating location. Mount DeviceNet PLC Controller and User Interface. Install ...

  • Lincoln Electric POWER WAVE 11124 - page 23

    A-13 INST ALLA TION POWER WAVE® AC/DC 1000 A-13 M M A A S S T T E E R R S S L L A A V V E E K 179 5- XX C abl es Connecti on Diagram - Parallel M achines (Example depicts a sin gle arc grouping, and may be repeated for each arc in th e syste m) Connect additional SLAVE machines as required to reach desired capacity. Note: Each arc is li mited to 5 ...

  • Lincoln Electric POWER WAVE 11124 - page 24

    A-14 INST ALLA TION POWER WAVE® AC/DC 1000 A-14 STEP BY STEP INST ALLA TION CHECKLIST EXTRA CAPACITY PARALLEL CONNECTION (as shown in the Connection Diagram "Parallel Machines”) Follow all steps of Single, Tandem, or Triple Arc checklists. Be sure input power is disconnected prior to following the remaining steps. Control Cable Connections: ...

  • Lincoln Electric POWER WAVE 11124 - page 25

    A-15 INST ALLA TION POWER WAVE® AC/DC 1000 A-15 ELECTRODE AND WORK CONNECTIONS General Guidelines The unique switching structure of the Power Wave AC/DC 1000 allows it to produce DC positive, DC negative or AC output waveforms without reposition- ing the work and electrode leads. Additionally, no DIP switch changes are required to switch between t ...

  • Lincoln Electric POWER WAVE 11124 - page 26

    A-16 INST ALLA TION POWER WAVE® AC/DC 1000 A-16 CABLE INDUCT ANCE, AND ITS EFFECTS ON WELDING Excessive cable inductance will cause the welding performance to degrade. There are several factors that contribute to the overall inductance of the cabling system including cable size, and loop area. The loop area is defined by the separation distance be ...

  • Lincoln Electric POWER WAVE 11124 - page 27

    A-17 INST ALLA TION POWER WAVE® AC/DC 1000 A-17 c . Locate the 8-position DIP switch on the control board and look for switch 8 of the DIP switch. d . Using a pencil or other small object, slide the switch to the OFF position if the work sense lead is NOT connected . Conversely, slide the switch to the ON position if the work sense lead is pre- se ...

  • Lincoln Electric POWER WAVE 11124 - page 28

    A-18 INST ALLA TION POWER WAVE® AC/DC 1000 A-18 • For circumferential applications, connect all work leads on one side of the weld joint, and all of the work volt- age sense leads on the opposite side, such that they are out of the current path. PO WER SOURCE #2 PO WER SOURCE #1 PO WER SOURCE #1 PO WER SOURCE #2 PO WER SOURCE #2 PO WER SOURCE #1 ...

  • Lincoln Electric POWER WAVE 11124 - page 29

    A-19 INST ALLA TION POWER WAVE® AC/DC 1000 A-19 CONTROL CABLE CONNECTIONS General Guidelines Genuine Lincoln control cables should be used at all times (except where noted otherwise). Lincoln cables are specifically designed for the communica- tion and power needs of the Power Wave / Power Feed systems. Most are designed to be connected end to end ...

  • Lincoln Electric POWER WAVE 11124 - page 30

    A-20 INST ALLA TION POWER WAVE® AC/DC 1000 A-20 Connections Between Multiple Power Sources Run in Parallel (K1795 - Control Cable). To increase the output capacity for a given arc, the output studs of multiple Power Wave AC/DC 1000 machines can be connected in parallel. The parallel machines utilize a master/slave control scheme to distribute the ...

  • Lincoln Electric POWER WAVE 11124 - page 31

    A-21 INST ALLA TION POWER WAVE® AC/DC 1000 A-21 EXTERNAL I/O CONNECT OR The Power Wave AC/DC 1000 is equipped with a ter- minal strip for making simple input signal connections. (See Figure A.2a) The terminal strip is located under- neath the spring-loaded cover, and divided into three groups: FIGURE A.2a Trigger group, Cold Inch Group and Shutdow ...

  • Lincoln Electric POWER WAVE 11124 - page 32

    A-22 INST ALLA TION POWER WAVE® AC/DC 1000 A-22 Table A.7 External I/O S7 (12 pin – terminal block) PIN Lead # Function 1 851 +15vdc for Trigger group 2 852 Trigger input 3 853 Dual procedure input 4 854 4 step input (Disabled as of S25564-19) 5 855 +15vdc for cold inch group (Disabled as of S25564-19) 6 856 cold inch forward 7 857 cold inch rev ...

  • Lincoln Electric POWER WAVE 11124 - page 33

    A-23 INST ALLA TION POWER WAVE® AC/DC 1000 A-23 WIRE DRIVE GEAR RA TIO SETTING Changing the wirefeeder gear ratio re quires a gear change in the wire drive, and a configuration change at t he power source. The P ower Wave AC/DC 1000 can be configured to support up to 4 unique gear ratios. The gear ratio configuration is selected via a DIP switch o ...

  • Lincoln Electric POWER WAVE 11124 - page 34

    A-24 INST ALLA TION POWER WAVE® AC/DC 1000 A-24 ELECTRIC SHOCK can kill. • Do not touch electric ally live parts or electrodes with your skin or wet clothing. • Insulate yourself from the work and ground. • Always wear dry insulating gloves. ----------------------------------------------------------- 1. Turn off power at the disconnect switc ...

  • Lincoln Electric POWER WAVE 11124 - page 35

    Switch Description 1 Object Instance LSB* (see table A.14) 2 Object Instance MSB** (see table A.14) 3 Equipment Group 1 Select (default OFF) 4 Equipment Group 2 Select (default OFF) 5 Equipment Group 3 Select (default OFF) 6 Equipment Group 4 Select (default OFF) Arclink Object Auto mapping enabled (default) Arclink Object Auto mapping disabled Wor ...

  • Lincoln Electric POWER WAVE 11124 - page 36

    A-26 INST ALLA TION POWER WAVE® AC/DC 1000 A-26 TABLE A.14 OBJECT INST ANCE switch 2 switch 1 Instance off off 0(default) off on 1 on off 2 on on 3 TABLE A.15 Switch 1 Switch 2 Baud Rate off off 125K (default) on off 250K off on 500K on on Programmable value. DeviceNet Baud Rate: ...

  • Lincoln Electric POWER WAVE 11124 - page 37

    A-27 INST ALLA TION POWER WAVE® AC/DC 1000 A-27 DEVICENET MAC ID TABLE A.16 Mac I.D. Switch 8 Switch7 Switch6 Switch5 Switch4 Switch 3 0 0 0 0 0 0 0 Software Selectable 1 000001 2000010 3000011 4000100 5000101 6000110 7000111 8001000 9001001 10 001010 11 001011 12 001100 13 001101 14 001110 15 001111 16 010000 17 010001 18 010010 19 010011 20 0101 ...

  • Lincoln Electric POWER WAVE 11124 - page 38

    A-28 INST ALLA TION POWER WAVE® AC/DC 1000 A-28 1 2 3 4 5 6 7 8 O N 1 2 3 4 5 6 7 8 O N 1 2 3 4 5 6 7 8 O N 1 2 3 4 5 6 7 8 O N 1 2 3 4 5 6 7 8 O N 1 2 3 4 5 6 7 8 O N ETHERNET BOARD DIP SWITCHES (S3, S4): MASTER Internal Synchronization Signal (for systems without K2282-1 System Interface) “BANK S4” Master / Slave Config “BANK S3” I / O T ...

  • Lincoln Electric POWER WAVE 11124 - page 39

    B-1 OPERA TION B-1 POWER WAVE® AC/DC 1000 SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill. • Unless using cold feed feature, when feeding with gun trigger, the elec- trode and d rive mechanism are always electrically energized and could remain energized several sec- onds ...

  • Lincoln Electric POWER WAVE 11124 - page 40

    B-2 OPERA TION POWER WAVE® AC/DC 1000 B-2 INPUT POWER ON OFF HIGH TEMPERA TURE MACHINE ST A TUS CIRCUIT BREAKER WIRE FEEDER POSITIVE OUTPUT NEGA TIVE OUTPUT 3 PHASE INVERTER INPUT POWER THREE PHASE DIRECT CURRENT OPEN CIRCUIT VOL T AGE INPUT VOL T AGE OUTPUT VOL T AGE INPUT CURRENT OUTPUT CURRENT PROTECTIVE GROUND W ARNING or CAUTION Explosion Dan ...

  • Lincoln Electric POWER WAVE 11124 - page 41

    B-3 OPERA TION B-3 POWER WAVE® AC/DC 1000 PRODUCT SUMMAR Y The Power Wave AC/DC 1000 is a high performance, digitally controlled inverter welding power source. It is capable of producing a variable frequency and ampli- tude AC output, DC positive output, or DC negative output without the need for external reconnection. It utilizes complex, high-sp ...

  • Lincoln Electric POWER WAVE 11124 - page 42

    (See Figure B.5) 4. 10 Amp Wire Feeder Circuit Breaker: Protects 40 volt DC wire feeder power supply. 5 . 115 VAC Auxiliary Power Circuit Breaker: Protects case front receptacle auxiliary supply. (10 amps) 6. 21 Work Sense Lead Connector(4-Pin) 7. Arclink Connector (5-Pin) 8. DeviceNet Connector (5-Pin) 9. Work Output Studs 10. Electrode Output Stu ...

  • Lincoln Electric POWER WAVE 11124 - page 43

    B-5 OPERA TION B-5 POWER WAVE® AC/DC 1000 8 12 7 11 9 10 4 5 13 14 6 15 FIGURE B.5 ...

  • Lincoln Electric POWER WAVE 11124 - page 44

    B-6 OPERA TION B-6 9. AC Switch Assembly W/Impeller Fan 10. Optional CE Filter Assembly (not shown): CE compliance filter connects in series with input con- nection. Available for K2344-2 only. POWER-UP SEQUENCE When power is applied to the Power Wave AC/DC 1000, the status lights will flash green, for up to 15 seconds. This is normal and indicates ...

  • Lincoln Electric POWER WAVE 11124 - page 45

    B-7 OPERA TION B-7 DUTY CYCLE The Power Wave AC/DC is capable of welding at a 100% duty cycle (continuous welding). COMMON WELDING PROCEDURES MAKING A WELD The serviceability of a product or structure utiliz- ing the welding programs is and must be the sole responsibility of the builder/user. Many variables beyond the control of The Lincoln Electri ...

  • Lincoln Electric POWER WAVE 11124 - page 46

    B-8 OPERA TION B-8 MUL TIPLE ARC SYSTEM CONSIDERA TIONS Large scale SAW applications often employ multiple arcs to increase deposition rates. In multiple arc sys- tems, magnetic forces created by like and opposing weld currents of adjacent arcs can result in arc inter- action that can physically push or pull the arc columns together. To counteract ...

  • Lincoln Electric POWER WAVE 11124 - page 47

    B-9 OPERA TION B-9 WELD SEQUENCE: The weld sequence defines the weld procedure from beginning to end. The Power Wave AC/DC 1000 not only provides adjustment of basic welding parameters, but also allows the operator to fine tune the start and finish of each weld for superior performance. All adjustments are made through the user interface. Because o ...

  • Lincoln Electric POWER WAVE 11124 - page 48

    B-10 OPERA TION B-10 WELD PROCESS ADJUSTMENTS Depending on the weld mode, there are a number of adjustments that can be made, including but not limit- ed to Current, Voltage and WFS. These adjustments apply to either AC or DC processes, and control the basic parameters of the weld. AC ADJUSTMENTS In addition to the basic weld parameters, there are ...

  • Lincoln Electric POWER WAVE 11124 - page 49

    B-11 OPERA TION B-11 MU L TI PLE ARC AC ADJ UST ME NTS FO R SYSTEMS EQUIPPED WITH K2282-1 SYSTEM INTERF ACE Phase The phase relationship between the arcs helps to minimize the magnetic interaction between adjacent arcs. It is essentially a time offset between the wave- forms of different arcs, and is set in terms of an angle from 0 to 360°, repres ...

  • Lincoln Electric POWER WAVE 11124 - page 50

    C-1 ACCESSORIES C-1 KITS, OPTIONS AND ACCESSORIES OPTIONAL KITS AND ACCESSORIES K2282-1 Power Wave System Interface The optional Power Wave System Interface provides the means to synchronize the AC wave shapes of up to four different arcs to a common carrier frequency. This frequency can range from 10 hertz to 300 hertz, with the most practical ran ...

  • Lincoln Electric POWER WAVE 11124 - page 51

    D-1 MAINTENANCE D-1 POWER WAVE® AC/DC 1000 SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only Qualified personnel should perform this maintenance. • Turn the input power OFF at the disconnect switch or fuse box before working on this equip- ment. • Do not touch electrically hot parts. --------------------------------------------------------- ...

  • Lincoln Electric POWER WAVE 11124 - page 52

    E-1 TROUBLESHOOTING E-1 POWER WAVE® AC/DC 1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and ...

  • Lincoln Electric POWER WAVE 11124 - page 53

    E-2 TROUBLESHOOTING E-2 POWER WAVE® AC/DC 1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION Observe all Safety Guidelines detailed throughout this manual ...

  • Lincoln Electric POWER WAVE 11124 - page 54

    E-3 TROUBLESHOOTING E-3 POWER WAVE® AC/DC 1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION Observe all Safety Guidelines detailed throughout this manual ...

  • Lincoln Electric POWER WAVE 11124 - page 55

    E-4 TROUBLESHOOTING E-4 POWER WAVE® AC/DC 1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION Observe all Safety Guidelines detailed throughout this manual ...

  • Lincoln Electric POWER WAVE 11124 - page 56

    E-5 TROUBLESHOOTING E-5 POWER WAVE® AC/DC 1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION Observe all Safety Guidelines detailed throughout this manual ...

  • Lincoln Electric POWER WAVE 11124 - page 57

    E-6 TROUBLESHOOTING E-6 POWER WAVE® AC/DC 1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION ...

  • Lincoln Electric POWER WAVE 11124 - page 58

    E-7 TROUBLESHOOTING E-7 POWER WAVE® AC/DC 1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION ...

  • Lincoln Electric POWER WAVE 11124 - page 59

    E-8 TROUBLESHOOTING E-8 POWER WAVE® AC/DC 1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION ...

  • Lincoln Electric POWER WAVE 11124 - page 60

    E-9 TROUBLESHOOTING E-9 POWER WAVE® AC/DC 1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION ...

  • Lincoln Electric POWER WAVE 11124 - page 61

    E-10 TROUBLESHOOTING E-10 POWER WAVE® AC/DC 1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTI ...

  • Lincoln Electric POWER WAVE 11124 - page 62

    E-11 TROUBLESHOOTING E-11 POWER WAVE® AC/DC 1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTI ...

  • Lincoln Electric POWER WAVE 11124 - page 63

    E-12 TROUBLESHOOTING E-12 POWER WAVE® AC/DC 1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION USING THE ST A TUS LED T O TROUBLESHOOT SYSTEM PROBLEMS The ...

  • Lincoln Electric POWER WAVE 11124 - page 64

    E-13 TROUBLESHOOTING E-13 POWER WAVE® AC/DC 1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION Observe all Safety Guidelines detailed throughout this manu ...

  • Lincoln Electric POWER WAVE 11124 - page 65

    E-14 TROUBLESHOOTING E-14 POWER WAVE® AC/DC 1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTI ...

  • Lincoln Electric POWER WAVE 11124 - page 66

    F-1 DIAGRAMS F-1 POWER WAVE® AC/DC 1000 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment ...

  • Lincoln Electric POWER WAVE 11124 - page 67

    F-2 DIAGRAMS F-2 POWER WAVE® AC/DC 1000 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment ...

  • Lincoln Electric POWER WAVE 11124 - page 68

    F-3 AC SWITCH WIRING DIAGRAM F-3 POWER WAVE® AC/DC 1000 ...

  • Lincoln Electric POWER WAVE 11124 - page 69

    F-4 AC SWITCH WIRING DIAGRAM F-4 POWER WAVE® AC/DC 1000 ...

  • Lincoln Electric POWER WAVE 11124 - page 70

    F-5 DIMENSION PRINT F-5 POWER WAVE® AC/DC 1000 L 12 30 2 A .0 1 19.70 19.16 9.56 18.84 40.94 43.44 33.00 34.34 14.62 ...

  • Lincoln Electric POWER WAVE 11124 - page 71

    NOTES POWER WAVE® AC/DC 1000 ...

  • Lincoln Electric POWER WAVE 11124 - page 72

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUFACTURER ’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA EL ...

  • Lincoln Electric POWER WAVE 11124 - page 73

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out o f fumes . ● Use ventil atio n or e xhaust to remo ve fum ...

  • Lincoln Electric POWER WAVE 11124 - page 74

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabricant Lincoln Electric Catégorie Welder

Les documents que nous recevons du fabricant de l'appareilLincoln Electric POWER WAVE 11124 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lincoln Electric
- manuels d’utilisations POWER WAVE 11124
- fiches produit Lincoln Electric
- dépliants
- ou étiquettes-énergie Lincoln Electric POWER WAVE 11124
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lincoln Electric POWER WAVE 11124.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lincoln Electric POWER WAVE 11124, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lincoln Electric POWER WAVE 11124. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lincoln Electric POWER WAVE 11124.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Lincoln Electric POWER WAVE 11124, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lincoln Electric POWER WAVE 11124 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lincoln Electric POWER WAVE 11124.

Le manuel d’utilisation complet Lincoln Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lincoln Electric POWER WAVE 11124 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lincoln Electric POWER WAVE 11124, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLincoln Electric POWER WAVE 11124 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lincoln Electric POWER WAVE 11124 - qui devraient nous aider dans les premières étapes lors de l'utilisation Lincoln Electric POWER WAVE 11124
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lincoln Electric POWER WAVE 11124
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lincoln Electric POWER WAVE 11124 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lincoln Electric POWER WAVE 11124?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lincoln Electric POWER WAVE 11124, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lincoln Electric POWER WAVE 11124 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)