  • Fluke 175 - page 1

    ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation. All right s reserved. Printed in USA. ...

  • Fluke 175 - page 2

    Lifeti m e Limi ted Warr a n ty Ea c h Fl u k e 20, 70, 80, 17 0 and 18 0 S eri es DM M wil l b e f ree f rom de f e c ts in m a t eri al an d wor k ma n s hi p f or i t s li f e t ime. As u s ed h erein, “li f e- t ime ” is de f ined a s s e v e n y ears a ft e r Fl u k e dis c on t inues man u f ac t uri ng t h e produ c t, b u t t he warran ...

  • Fluke 175 - page 3

    i Table of Contents Titl e Page Con tacting Fluk e ............................................................................................................... .... 1 "Warn ing" and "C aution " State ments ..................................................................................... 1 Unsafe Vol tage ................. ...

  • Fluke 175 - page 4

    ii Warning . Rea d be fore u sing the Mete r: To avoid possible electrical shock or personal injury, follow these guidelines: ⇒ Use the Meter only as spec ified in this ma nual or the pr otection p rovided by t he Meter might be im paired. ⇒ Do not use the Meter or test leads if they appear damaged , or if the Meter is not operating pr operly. ...

  • Fluke 175 - page 5

    1 Models 175, 177 & 179 True RMS Multimeters The Fluke Model 175 , Model 177 , and Model 179 are batter y - powered, t rue-RMS m u l t i me t ers (herea ft er " t he Me t er" ) wi t h a 6000- c ount, 3 3/4-di gi t di s play and a bar graph. Thi s manual applies t o al l t hree m odel s . All f igures s how the M odel 179. These meters ...

  • Fluke 175 - page 6

    Models 175, 177 & 179 Users M anual 2 Battery Saver ("Sleep Mode") The Meter enters the "Sleep m ode" and blanks t he di s play if t here is no func tion change or but t on press for 20 m inutes. To di s able the Sleep m ode, hol d down t he YELLOW button while t urni ng t he Meter on. The S l eep m ode i s always di s abled ...

  • Fluke 175 - page 7

    Displ ay 3 Display . 8 7 7 5 6 4 3 2 1 13 14 15 9 11 12 10 AIK02F.EPS No. Symbol Meaning 1 s Continuit y t est. 2 Diode test . 3 K Negative readi ngs . 4 Y Unsafe v ol t age. Voltage ≥ 30 V , or voltage ov erload ( OL ) 5 Displ ay HOLD is enabl ed. Display freezes pres ent reading. In MIN M AX AV G mode, MI N MAX AVG recordi ng i s interrupted. A ...

  • Fluke 175 - page 8

    Models 175, 177 & 179 Users M anual 4 MIN MAX AVG Recording M ode The MIN MA X A VG recording m ode c aptures the m i ni m um and maximum input values , and calc ulates a runni ng av erage of all readings. When a new hi gh or l ow i s detected, the Meter beeps . Note For DC funct i ons , accurac y is the s pecifi ed ac curacy of t he measuremen ...

  • Fluke 175 - page 9

    Manual Ranging and Autoranging 5 Manual Ranging and Autoranging The Meter has bot h Manual range and Autorange m odes . ⇒ In the Aut orange mode, the M et er s elects the range with t he best res ol ut i on. ⇒ In the Manual Range m ode, you override A ut orange and select the range yoursel f . When you turn the M eter on, it def aults t o A uto ...

  • Fluke 175 - page 10

    Models 175, 177 & 179 Users M anual 6 Making Basic Measurements The figures on t he f ollowing pages s how how to make bas ic measurement s. When connect i ng t he t est leads to the ci rc uit or devi c e, connect the comm on ( COM ) test l ead bef ore c onnecting t he live lead; when removing t he t est leads , remove the l i v e lead before r ...

  • Fluke 175 - page 11

    Making Basic Measurem ents 7 Testing for Continuit y RANGE HOLD MIN MA X RANGE HOLD MIN MA X AIK06F.EPS Measuring Temperature (Model 179 Only) RANGE HOLD MIN MAX 80BK1 Type K Thermocouple Probe Vent or Pipe RANGE AIK10F.EPS Warning: Do not connect 80BK1 to liv e c irc uit s . Testing Diodes + __ Forward Bias Single Beep + Reverse Bias Good Diode Go ...

  • Fluke 175 - page 12

    Models 175, 177 & 179 Users M anual 8 Measuring AC or DC Current Warning To avoid personal injury or damage to the Meter: • Never attempt to make an i n-ci rcuit current measure- ment when the open-circuit potential to earth is > 1000 V. • Check the Meter's fuses before testing. (See “ Testing the Fuses”.) • Use the proper ter ...

  • Fluke 175 - page 13

    Using the Bar Graph 9 Measuring Frequency Warning To avoid electrical shock, di sregard the bar graph for frequencies > 1 kHz. I f the frequency of the m easured signal is > 1 kHz, the bar graph is unspecified. The Meter meas ures the frequency of a signal . The trigger level i s 0 V, 0 A A C f or all ranges. + RANGE HOLD MIN MAX Hz RANGE HOL ...

  • Fluke 175 - page 14

    Models 175, 177 & 179 Users M anual 10 Cleaning Wipe the cas e with a damp c l ot h and m i l d det ergent. Do not us e abrasives or solvent s . Dirt or m oi s ture in the t erm i nal s can aff ec t readings. Testing the Fuses Warning To avoid electrical shock or injury, rem ove the test leads and any input signals before replacing the fuse. Te ...

  • Fluke 175 - page 15

    Specifications 11 Specifications Accuracy is s pec if ied f or 1 y r af t er c alibrat ion, at operat ing t emperatures of 18 ° C to 28 ° C, with relative humidity at 0 % t o 95 %. Ac c urac y specificat ions t ak e t he f orm of: ± ( [ % of Reading ] + [ Counts ] ) Maximum voltage between any termi nal and earth gr ound: 1000 V DC or AC RM S Su ...

  • Fluke 175 - page 16

    Models 175, 177 & 179 Users M anual 12 Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range 1 Res ol ution Model 17 5 Model 177 Model 17 9 AC Volts 2,3 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 1. ...

  • Fluke 175 - page 17

    Specifications 13 Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range 1 Res ol ution Model 17 5 Model 177 Model 17 9 DC Amps 4 60.00 mA 400.0 mA 6.000 A 10.00 A 0.01 mA 0.1 mA 0.001 A 0.01 A 1.0 % + 3 1.0 % + 3 1.0 % + 3 Hz (AC- or DC- coupled, V or A 2, 3 input ) 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 ...

  • Fluke 175 - page 18

    Models 175, 177 & 179 Users M anual 14 Function Overload Protection 1 Input Im pe da nc e (Nominal) Common Mode Rejection Ratio (1 k Ω Unbalanced) Normal Mode Rejecti on Volts AC 1000 V RMS > 10 M Ω < 100 pF > 60 dB @ DC, 50 Hz or 60 Hz Volts DC 1000 V RMS > 10 M Ω <100 pF >120 dB @ DC, 50 Hz or 60 Hz > 60 dB @ 50 Hz ...

Fabricant Fluke Catégorie Video Game Keyboard

Les documents que nous recevons du fabricant de l'appareilFluke 175 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Fluke
- manuels d’utilisations 175
- fiches produit Fluke
- dépliants
- ou étiquettes-énergie Fluke 175
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Fluke 175.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Fluke 175, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Fluke 175. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Fluke 175.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Fluke 175, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Fluke 175 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Fluke 175.

Le manuel d’utilisation complet Fluke, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Fluke 175 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Fluke 175, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFluke 175 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Fluke 175 - qui devraient nous aider dans les premières étapes lors de l'utilisation Fluke 175
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Fluke 175
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Fluke 175 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Fluke 175?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Fluke 175, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Fluke 175 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)