    FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-896 CS1200 Alterra™ Freestanding W ood Sto ve 07/05/10 Owner's & Installation Manual T ested by: Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep these instructions for fu ...

  • Regency CS1200 - page 2

    Regency CS1200 Wood Cast Insert 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY ...

  • Regency CS1200 - page 3

    Regency CS1200 F reestanding W ood Stov e 3 SAFETY LABEL This is a copy of the label that accompanies each CS1200 Wood Stove . W e have printed a copy of the contents here for your review . HOT WHILE IN OPERA TION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE A W A Y . CONT ACT MA Y CAUSE SKIN BURNS. READ NAMEPLA TE AND INSTRUCTIONS. DO NOT R ...

  • Regency CS1200 - page 4

    4 Regency CS1200 F reestanding W ood Stov e T ABLE OF CONTENTS SAFETY LABEL Copy of the Safety Label ............................................... 3 DIMENSIONS Unit Dimensions ............................................................ 5 INST ALLA TION Residential Installation................................................... 6 Room Air ....... ...

  • Regency CS1200 - page 5

    Regency CS1200 F reestanding W ood Stov e 5 DIMENSIONS UNIT DIMENSIONS 9-15/16 ” 14-7/16 ” 39-9/16 ”( 1 1 0 5 m m ) 17-1/8” (436mm) 26-3/4”(680mm) A A 21-3/4” (552mm) 37-13/16” (961mm) 19-1/16” (485mm) (250mm) (367mm) 17-1/8” (436mm) 27-1/8” (689mm) 9-15/16” (250mm) 7-5/16” (186mm) 17-1/8” (435mm) CL for outside ai r 6&quo ...

  • Regency CS1200 - page 6

    6 Regency CS1200 F reestanding W ood Stov e INST ALLA TION RESIDENTIAL INST ALLA TION 1) Read all instructions before installing your Re- gency Stove. Install and use only in accordance with these installation and operating instructions. Be aware that local Codes and Regulations may override some items in this manual. Check with your local inspecto ...

  • Regency CS1200 - page 7

    Regency CS1200 F reestanding W ood Stov e 7 INST ALLA TION MINIMUM CLEARANCE T O COMBUSTIBLE MA TERIALS MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE T O A SIDE W ALL OR T O A CORNER, AND FROM THE REAR HEA T SHIELD TO A BACK W ALL NO TE: Be a ware that local Codes and Regulations may o verride some clearances listed in t ...

  • Regency CS1200 - page 8

    8 Regency CS1200 F reestanding W ood Stov e INST ALLA TION Z 6" 6" 16" Y Y X X 6" for angled corners 6" 16" 6" 6" Z The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" Maximum d ...

  • Regency CS1200 - page 9

    Regency CS1200 F reestanding W ood Stov e 9 INST ALLA TION Horizontal Installation Standard Ceiling Installation 8) T o complete your chimney installation, install the double wall connector pipe from the stove’s fl ue collar to the chimney support device. 9) If you are using a horizontal connector , the chimney connector should be as high as pos ...

  • Regency CS1200 - page 10

    10 Regency CS1200 F reestanding W ood Stov e INST ALLA TION F ACTOR Y BUIL T CHIMNEY When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. Y ou must also purchase and install the ceiling support package or wall pass-through and "T" section package, fi restops (where needed), insul ...

  • Regency CS1200 - page 11

    Regency CS1200 F reestanding W ood Stov e 11 INST ALLA TION Method A : 12" (304.8 mm) Clearance to Combustible W all Member: Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner , construct a wall pass-through. The clay liner must conform to ASTM C315 (Standard Speci fi cation for Clay ...

  • Regency CS1200 - page 12

    12 Regency CS1200 F reestanding W ood Stov e INST ALLA TION MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET (Measured from the top of the unit) # OF ELBOWS ELEV A TION (FT) ABOVE SEA LEVEL 0 2 x 15 o 4 x 15 o 2 x 30 o 4 x 30 o 2 x 45 o 4 x 45 o 0-1000 12.0 13.0 14.0 15.0 18.0 16.0 20.0 1000-2000 12.5 13.5 14.5 15.5 19.0 16.5 21.0 2000-3000 13.0 14.0 15.0 ...

  • Regency CS1200 - page 13

    Regency CS1200 F reestanding W ood Stov e 13 INST ALLA TION MOBILE HOME INST ALLA TION W ARNING: Minimum height requirements must be met. Safe removal of the chimney system must be adhered to when transporting the mobile home. W ARNING: Operate only with door fully closed - open feed door to feed fi re only . Once you have properly marked the posi ...

  • Regency CS1200 - page 14

    14 Regency CS1200 F reestanding W ood Stov e INST ALLA TION SIMPSON DURA-PLUS Qty .Part # Description 1 6DVL8693 Connector Kit 1 6DP-MH9096 Mobile Home Kit ICC EXCEL 2100 Qty .Part # Description 1 6CL48 48" Chimney length (also in 12",18", 24" lengths. 1 6RC Rain Cap 1 6RCS Spark Screen (for rain cap) 1 6RDS/SQS Round/Square sup ...

  • Regency CS1200 - page 15

    Regency CS1200 F reestanding W ood Stov e 15 INST ALLA TION Side View Front View Front View 1) If the two air tubes are installed continue on to Step 2), if not, follow the instructions below . Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door . Slide the tube i ...

  • Regency CS1200 - page 16

    16 Regency CS1200 F reestanding W ood Stov e INST ALLA TION SIDE P ANEL INST ALLA TION Before installation, panels must be handled and cleaned as per instructions noted below: Stainless Steel Panels • Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after ...

  • Regency CS1200 - page 17

    Regency CS1200 F reestanding W ood Stov e 17 INST ALLA TION ASH DRA WER OPTION 2) Remove the bricks from the fl oor of the fi rebox. 5) Position ash drawer lid in 'Open' position on the ash drawer lid (towards the front) as shown below . 6) Slide in ash drawer . 7) Close center door and main top door- once ash drawer is in place. Keep a ...

  • Regency CS1200 - page 18

    18 Regency CS1200 F reestanding W ood Stov e INST ALLA TION LOWER SURROUND DOOR REVERSAL (LEFT TO RIGHT SIDE OPENING) 1) The lower surround door can be reversed - to open from the right. Make sure stove has cooled, open the door - and remove it from the hinge by removing 2 bolts. 2) Remove and discard the latch on the left side of the unit by remov ...

  • Regency CS1200 - page 19

    Regency CS1200 F reestanding W ood Stov e 19 INST ALLA TION CAST DOOR REVERSAL (LEFT TO RIGHT SIDE OPENING) 1) The door can be reversed - so that it will open to the left. Make sure stove has cooled to room temperature. Open the door to about 45 ° - then remove it from the hinge by lifting up and out. Note: Door is heavy . 2) Remove the 2 bolts se ...

  • Regency CS1200 - page 20

    20 Regency CS1200 F reestanding W ood Stov e INST ALLA TION OPTIONAL ASHLIP INST ALLA TION WOOD ST ORAGE When storing wood within pedestal- ensure wood does not protrude past door opening. Do not store newspaper within pedestal. Note: Please refer to local codes. (B365, NFP A 21 1) and your local jurisdiction. Store wood behind door opening 1) Open ...

  • Regency CS1200 - page 21

    Regency CS1200 F reestanding W ood Stov e 21 INST ALLA TION 1) Remove the fi ve screws from the back panel of the unit - to remove the fan cover plate. 2) Slide the fan up into the rear heat shield. 3) After aligning holes, secure the fan to the rear heat shield using the fi ve screws removed earlier . 4) Secure the bottom of the fan using the tw ...

  • Regency CS1200 - page 22

    22 Regency CS1200 F reestanding W ood Stov e 22 OPERA TING INSTRUCTIONS 8) Do not place anything on the stove top during the curing process. This may result in damage to your paint fi nish. 9) During the fi rst few days it may be more dif fi cult to start the fi re. As you dry out your fi rebrick and your masonry fl ue, your draft will increa ...

  • Regency CS1200 - page 23

    Regency CS1200 F reestanding W ood Stov e 23 OPERA TING INSTRUCTIONS ASH DISPOSAL During constant use, ashes should be removed every few days. The Ash Drawer option features a convenient ash dump for easy removal of ash, refer to the "Modular Options" section. Safety Precautions 1) Do not allow ashes to build up to the loading doors! Only ...

  • Regency CS1200 - page 24

    24 Regency CS1200 F reestanding W ood Stov e MAINTENANCE SAFETY GUIDELINES AND W ARNINGS 1) Never use gasoline, gasoline type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or ‘freshen up’ a fi re in your heater . Keep all such liquids well away from the heater while it is in use. 2) Keep the door closed during ope ...

  • Regency CS1200 - page 25

    Regency CS1200 F reestanding W ood Stov e 25 MAINTENANCE CREOSOTE When wood is burned slowly , it produces tar and other organic vapors, which when combined with moisture, form creosote. The creosote vapors condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosote residue accumulates on the fl ue lining. When i ...

  • Regency CS1200 - page 26

    26 Regency CS1200 F reestanding W ood Stov e P AR TS LIST 1 6 13 14 11 3 2 9 4 5 10 7 8 12 Part # Description 1) 076-201 Cast Stove T op 2) 076-21 1 Cast Pedestal 3) 156-21 1 Surround Bottom 4) 156-513 Curved Door Assembly 5) 156-261 Thin Surround 6) 076-921 Side Shield (Black Set) 076-927 Side Shield (Stainless Set) 7) 156-519 Door Catch Assembly ...

  • Regency CS1200 - page 27

    Regency CS1200 F reestanding W ood Stov e 27 P AR TS LIST Part # Description 200-917 Fan Assembly Package 1) 220-026 Fan Housing Front 2) 222-022 Fan Housing Bottom 3) 222-036 Sensor Mount 4) 200-227 Fan Bracket Right Hand 5) 200-228 Fan Bracket Left Hand 6) 200-229 Fan Housing Back 7) 910-157/P Fan 8) 910-142 Thermodisc Part # Description 1) 073-9 ...

  • Regency CS1200 - page 28

    28 Regency CS1200 F reestanding W ood Stov e NO TES ...

  • Regency CS1200 - page 29

    Regency CS1200 F reestanding W ood Stov e 29 NO TES ...

  • Regency CS1200 - page 30

    30 Regency CS1200 F reestanding W ood Stov e NO TES ...

  • Regency CS1200 - page 31

    Regency CS1200 F reestanding W ood Stov e 31 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty t ...

  • Regency CS1200 - page 32

    32 Regency CS1200 F reestanding W ood Stov e 32 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________ ...

Fabricant Regency Catégorie Stove

Les documents que nous recevons du fabricant de l'appareilRegency CS1200 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Regency
- manuels d’utilisations CS1200
- fiches produit Regency
- dépliants
- ou étiquettes-énergie Regency CS1200
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Regency CS1200.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Regency CS1200, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Regency CS1200. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Regency CS1200.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Regency CS1200, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Regency CS1200 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Regency CS1200.

Le manuel d’utilisation complet Regency, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Regency CS1200 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Regency CS1200, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRegency CS1200 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Regency CS1200 - qui devraient nous aider dans les premières étapes lors de l'utilisation Regency CS1200
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Regency CS1200
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Regency CS1200 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Regency CS1200?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Regency CS1200, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Regency CS1200 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)