Manuel d’utilisation Lincoln Electric SVM149-A

92 pages 2.3 mb
Télécharger

Aller à la page of 92

Summary
  • Lincoln Electric SVM149-A - page 1

    SVM149-A October , 2006 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation . . . and thoughtful operation on your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WITHOUT READ- ING THIS MANUAL AND THE SAFETY PRECA ...

  • Lincoln Electric SVM149-A - page 2

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJUR Y OR DEA TH. KEEP CHILDREN AW AY . P ACEMAKER WEARERS SHOULD CONSUL T WITH THEIR DOCTOR BEFORE OPERA TING. Read and understand the following safety highlights. For additional safety information it is strongly r ...

  • Lincoln Electric SVM149-A - page 3

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 4.c. When not cutting or gouging, make certain no part of the elec- trode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard. 4.d. Do not cut or gouge tanks, drums or containers until the proper steps have been ...

  • Lincoln Electric SVM149-A - page 4

    SAFETY iii iii Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pou ...

  • Lincoln Electric SVM149-A - page 5

    MASTER T ABLE OF CONTENTS FOR ALL SECTIONS iv iv PRO-CUT 25 Page Safety .................................................................................................................................................i-iii Installation .................................................................................................................. ...

  • Lincoln Electric SVM149-A - page 6

    PRO-CUT 25 Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES ...

  • Lincoln Electric SVM149-A - page 7

    T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 PRO-CUT 25 Installation T echnical Specifications ....................................................................................................... ......A-2 Safety Precautions.................................................................................................. ...

  • Lincoln Electric SVM149-A - page 8

    INST ALLA TION A-2 A-2 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC W eight Including T orch Cable 35 lbs. 15.9 kg. INPUT - SINGLE PHASE / 60 HERTZ ONL Y RA TED OUTPUT OUTPUT RECOMMEND INPUT WIRE AND FUSE SIZES R ...

  • Lincoln Electric SVM149-A - page 9

    INST ALLA TION A-3 A-3 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Read entire Installation Section before installing the PRO-CUT 25. SAFETY PRECAUTIONS ELECTRIC SHOCK CAN KILL. • Only qualified personnel shou ...

  • Lincoln Electric SVM149-A - page 10

    INST ALLA TION A-4 A-4 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC • Failure to wire as instructed may cause personal injury or damage to equipment. • T o be installed or checked by an electrician or qualifi ...

  • Lincoln Electric SVM149-A - page 11

    INST ALLA TION A-5 A-5 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTE: When using nitrogen gas from a cylinder , the cylinder must have a pressure regulator . • Maximum psi from a nitrogen gas cylinder to th ...

  • Lincoln Electric SVM149-A - page 12

    NOTES A-6 A-6 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 13

    Section B-1 Section B-1 PRO-CUT 25 T ABLE OF CONTENTS - OPERA TION SECTION - Operation ............................................................................................................................... Section B Safety Precautions .......................................................................................................... ...

  • Lincoln Electric SVM149-A - page 14

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-2 B-2 PRO-CUT 25 OPERA TION Read and understand this entire section before operat- ing the machine. SAFETY PRECAUTIONS DESCRIPTION The PRO-CUT 25 is a constant current, continu ...

  • Lincoln Electric SVM149-A - page 15

    OPERA TION B-3 B-3 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC USER RESPONSIBILITY Because design, fabrication, erection and cutting vari- ables affect the results obtained in applying this type of information, ...

  • Lincoln Electric SVM149-A - page 16

    OPERA TION B-4 B-4 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CUTTING CAP ABILITY The PRO-CUT 25 is rated at 25 amps, at 35% duty cycle on a 10 minute basis. If the duty cycle is exceeded, a thermal protector w ...

  • Lincoln Electric SVM149-A - page 17

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-5 B-5 PRO-CUT 25 LIMIT A TIONS Do not exceed output current and duty cycle rating of machine. Do not use the PRO-CUT 25 for pipe thaw- ing. CONTROLS AND SETTINGS Whe ...

  • Lincoln Electric SVM149-A - page 18

    OPERA TION B-6 B-6 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Direction of Travel 5 ° - 15 ° 10 ° - 20 ° Arc Lag Leading Angle • Use a 5° - 15° leading angle in the direction of the cut. • Finish the ...

  • Lincoln Electric SVM149-A - page 19

    OPERA TION B-7 B-7 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROCEDURE RECOMMENDA TIONS When properly used, plasma arc cutting is a very eco- nomical process. Improper use will result in a very high operating ...

  • Lincoln Electric SVM149-A - page 20

    NOTES B-8 B-8 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 21

    T ABLE OF CONTENTS - ACCESSORIES - Accessories ........................................................................................................................... Section C Options/Accessories...................................................................................................................C-2 Section C-1 Section C-1 PRO-CUT ...

  • Lincoln Electric SVM149-A - page 22

    ACCESSORIES C-2 C-2 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC AL W A YS USE GENUINE LINCOLN ELECTRIC ELECTRODES AND VORTECH ™ NOZZLES • Only Genuine Lincoln Electric consumables yield the best cutting perf ...

  • Lincoln Electric SVM149-A - page 23

    Section D-1 Section D-1 PRO-CUT 25 T ABLE OF CONTENTS -MAINTENANCE- Maintenance ......................................................................................................................... Section D Routine Maintenance ............................................................................................................ ......D-2 ...

  • Lincoln Electric SVM149-A - page 24

    MAINTENANCE D-2 D-2 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PERIODIC MAINTENANCE Change consumables as required. THERMAL PROTECTION Thermal Detection Devices protect the machine from excessive operating temp ...

  • Lincoln Electric SVM149-A - page 25

    L IN C O L N E L E C T R IC PRO-CUT 25 O N O F F P U R G E POWER GAS PRESSURE THERMAL SAFETY ! R E Q U I R E S 2 0 A / 1 1 5 V B R A N C H C I R C U I T R E Q U I R E S 3 0 A / 1 1 5 V B R A N C H C I R C U I T 2 5 2 0 P C T 2 0 6 1 2 4 3 5 7 MAINTENANCE D-3 D-3 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to ...

  • Lincoln Electric SVM149-A - page 26

    NOTES D-4 D-4 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 27

    Section E-1 Section E-1 PRO-CUT 25 Theory of Operation ............................................................................................................. Section E General Description ....................................................................................................................E-2 Input Line V oltage and Auxiliary T ...

  • Lincoln Electric SVM149-A - page 28

    FIGURE E.2 – INPUT LINE VOL T AGE GENERAL DESCRIPTION The PRO-CUT 25 is an inverter based constant current, continuous contr ol plasma cutting power source. The contr ol system has a safety mechanism to insure that the nozzle and electr ode are in place before cutting or gouging. The PRO-CUT 25 initiates the plasma arc with a simple, yet r eliabl ...

  • Lincoln Electric SVM149-A - page 29

    PRECHARGE AND PROTECTION The input voltage is rectified by the input r ectifier on the inverter board. The r esultant DC voltage is applied to the filter capacitors through the automatic r econnect of the input boar d. The input board also contains prechar ging circuitry for the safe char ging of the input filter capacitors. Once the capacitors are ...

  • Lincoln Electric SVM149-A - page 30

    THEOR Y OF OPERA TION E-4 E-4 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE E.4 – MAIN TRANSFORMER 115/230/1/50/60 VAC INPUT CN1 2 1 4 3 5 6 7 8 300uH L1 RL3 10/10W R1 V2 V1 B A 1A/250V F1 RL2 RL2 RL2 AC ...

  • Lincoln Electric SVM149-A - page 31

    OUTPUT SECTION AND TORCH The output section contains a relay which, upon r eceiving a pilot signal fr om the control boar d will enable the operation of a pilot arc or a cutting ar c. The printed circuit boar d mounted current sensor r egulates the pilot and cutting current. The output choke, which is in series with both the pilot circuit and the c ...

  • Lincoln Electric SVM149-A - page 32

    CONTROL BOARD The control boar d receives status and analog feedback signals from the inverter boar d, input board, and various sensors. The control cir cuitry interprets these signals, makes decisions and changes the machines mode and output to satisfy the requir ements as defined by the circuitry . The control board sends a signal to the inverter ...

  • Lincoln Electric SVM149-A - page 33

    PROTECTION CIRCUITS Protection cir cuits are designed into the PRO-CUT 25 machine to sense trouble, damages, pr oblems with internal components, and to provide safety . These ar e the main protection cir cuits: OVERLOAD PROTECTION The PRO-CUT 25 is electrically protected fr om producing higher than normal output curr ents. If the output current exc ...

  • Lincoln Electric SVM149-A - page 34

    INSULA TED GA TE BIPOLAR TRANSISTOR (IGBT) OPERA TION An IGBT is a type of transistor . IGBT s are semicon- ductors well suited for high frequency switching and high current applications. Drawing A shows an IGBT in a passive mode. There is no gate signal, zero volts r elative to the source, and therefor e, no current flow . The drain terminal of th ...

  • Lincoln Electric SVM149-A - page 35

    PRO-CUT 25 Section F-1 Section F-1 Tr oubleshooting & Repair Section ................................................................................. Section F How to Use T roubleshooting Guide ....................................................................................F-2 PC Board T roubleshooting Pr ocedures and Replacement ......... ...

  • Lincoln Electric SVM149-A - page 36

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 HOW TO USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory T rained Personnel. Unauthorized repairs performed on this equ ...

  • Lincoln Electric SVM149-A - page 37

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRIC SHOCK can kill. Have an electrician install and service this equipment. T ur n the machine OFF before working on equipment. Do not touch electrically hot part ...

  • Lincoln Electric SVM149-A - page 38

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-4 F-4 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not un ...

  • Lincoln Electric SVM149-A - page 39

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-5 F-5 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF M ...

  • Lincoln Electric SVM149-A - page 40

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-6 F-6 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF M ...

  • Lincoln Electric SVM149-A - page 41

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-7 F-7 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not un ...

  • Lincoln Electric SVM149-A - page 42

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-8 F-8 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do not un ...

  • Lincoln Electric SVM149-A - page 43

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-9 F-9 PRO-CUT 25 INPUT FIL TER CAP ACITOR DISCHARGE PROCEDURE W ARNING Service and repair should be performed by only Lincoln Electric factory tra ...

  • Lincoln Electric SVM149-A - page 44

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-10 F-10 PRO-CUT 25 ELECTRIC SHOCK can kill. • Have an electrician install and service this equipment. • T urn the input power off at the fuse ...

  • Lincoln Electric SVM149-A - page 45

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-11 F-11 PRO-CUT 25 W ARNING MAIN INVER TER BOARD RESIST ANCE TEST Service and repair should be performed by only Lincoln Electric factory trained ...

  • Lincoln Electric SVM149-A - page 46

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-12 F-12 PRO-CUT 25 MAIN INVER TER BOARD RESIST ANCE TEST (continued) FIGURE F .2 TEST PROCEDURE 1. Remove main input power to the PRO-CUT 25. 2. R ...

  • Lincoln Electric SVM149-A - page 47

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-13 F-13 PRO-CUT 25 MAIN INVER TER BOARD RESIST ANCE TEST (continued) FIGURE F .3 LOCA TION OF IGBT S (6) RIGHT SIDE OF MACHINE (NZL) WRK (EL) Harn ...

  • Lincoln Electric SVM149-A - page 48

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-14 F-14 PRO-CUT 25 MAIN INVER TER BOARD RESIST ANCE TEST (continued) 9. Check Diodes D1, D2, & D3 for “shorts” or “opens”. Keep in min ...

  • Lincoln Electric SVM149-A - page 49

    RIGHT SIDE OF MACHINE (NZL) WRK (EL) Harness Plug Plug J1 LEAD 3 LEAD 2 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-15 F-15 PRO-CUT 25 10. Remove the torch consumables. (Shield cup, Nozzle a ...

  • Lincoln Electric SVM149-A - page 50

    NOTES F-16 F-16 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 51

    TROUBLESHOOTING & REP AIR F-17 F-17 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INPUT BOARD VOL T AGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthori ...

  • Lincoln Electric SVM149-A - page 52

    TEST PROCEDURE 1. Remove input power to the PRO-CUT 25 machine. 2. Remove carrying handle using a 4mm allen wrench. 3. Using a crescent wr ench, carefully r emove the plastic nut fr om around the pressur e regulator located on the top of the machine. 4. Using a 7mm nut driver , r emove the case wraparound. 5. Perform the Capacitor Discharge Procedu ...

  • Lincoln Electric SVM149-A - page 53

    TROUBLESHOOTING & REP AIR F-19 F-19 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 10. After the relays activate check for 115V AC from both test points AC to CP . See Figure F .7. If this voltage is not presen ...

  • Lincoln Electric SVM149-A - page 54

    NOTES F-20 F-20 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 55

    F-21 F-21 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR MAIN INVER TER BOARD VOL T AGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. ...

  • Lincoln Electric SVM149-A - page 56

    TEST PROCEDURE 1. Remove input power to the PRO-CUT 25 machine. 2. Remove carrying handle using a 4mm allen wrench. 3. Using a crescent wr ench, carefully r emove the plastic nut fr om around the pressur e regulator located on the top of the machine. 4. Using a 7mm nut driver , remove the case wraparound. 5. Perform the Capacitor Discharge Procedur ...

  • Lincoln Electric SVM149-A - page 57

    10. Carefully test for 12VDC at test points C7. See Figure F .9. See the Wiring Diagram. This is the rectified and r egulated supply for the pulse width modulation circuit. 11. Carefully test for 12VDC at C18 test points. If it is not correct the contr ol board or associated wiring may be faulty . See the Wiring Diagram. See Figure F .9. 12. Carefu ...

  • Lincoln Electric SVM149-A - page 58

    NOTES F-24 F-24 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 59

    TORCH CONTINUITY AND SOLENOID TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid electrical shock, please observe all safet ...

  • Lincoln Electric SVM149-A - page 60

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-26 F-26 PRO-CUT 25 TORCH CONTINUITY AND SOLENOID TEST (continued) TEST PROCEDURE 1. Remove input power to the PRO-CUT 25 machine. 2. Remove carryi ...

  • Lincoln Electric SVM149-A - page 61

    TROUBLESHOOTING & REP AIR F-27 F-27 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TORCH CONTINUITY AND SOLENOID TEST (continued) T ABLE F .1 - TORCH ASSEMBL Y RESIST ANCES TEST CIRCUIT(S) BEING EXPECTED TEST P ...

  • Lincoln Electric SVM149-A - page 62

    NOTES F-28 F-28 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 63

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-29 F-29 PRO-CUT 25 W ARNING AIR/GAS SOLENOID TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unaut ...

  • Lincoln Electric SVM149-A - page 64

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-30 F-30 PRO-CUT 25 AIR/GAS SOLENOID TEST (continued) TEST PROCEDURE 1. Remove input power to the PRO-CUT 25 machine. 2. Remove carrying handle usi ...

  • Lincoln Electric SVM149-A - page 65

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-31 F-31 W ARNING CONTROL BOARD REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained ...

  • Lincoln Electric SVM149-A - page 66

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-32 F-32 PROCEDURE 1. Remove input power to the PRO-CUT 25 machine. 2. Remove carrying handle using a 4mm allen wrench. 3. Using a cresc ...

  • Lincoln Electric SVM149-A - page 67

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 7. A nut is located under the red plastic piece that you previously r emoved. Loosen this nut with a 6mm nut driver and remove. Plastic alignment spacer may come off w ...

  • Lincoln Electric SVM149-A - page 68

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 16. Replace the r ed PURGE button. 17. Replace the plastic OUTPUT knob, align it in its original position, and tighten nut. 18. Replace the red cap on the end of the O ...

  • Lincoln Electric SVM149-A - page 69

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-35 F-35 W ARNING INPUT BOARD REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained p ...

  • Lincoln Electric SVM149-A - page 70

    PROCEDURE 1. Remove input power to PRO-CUT 25. 2. Remove carrying handle using a 4mm allen wrench. 3. Using a cr escent wrench, car efully r emove the plastic nut fr om around the pressur e regulator located on the top of the machine. 4. Using a 7mm nut driver , remove the case wraparound. 5. Perform Capacitor Discharge Procedure. Be sure to follow ...

  • Lincoln Electric SVM149-A - page 71

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRO-CUT 25 TROUBLESHOOTING & REP AIR F-37 F-37 FIGURE F.17 – INPUT BOARD REMOVAL Fan Leads Four Leads Switch Leads Mounting Screws Multi-colored Plug Mounting Screws A B AC ...

  • Lincoln Electric SVM149-A - page 72

    NOTES F-38 F-38 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 73

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-39 F-39 W ARNING MAIN INVER TER BOARD REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory ...

  • Lincoln Electric SVM149-A - page 74

    CAUTION PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-40 F-40 FIGURE F.18 – MAIN INVERTER BOARD REMOVAL MAIN INVER TER BOARD REMOV AL & REPLACEMENT (continued) PROCEDURE 1. Re ...

  • Lincoln Electric SVM149-A - page 75

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-41 F-41 FIGURE F.19 – INVERTER BOARD LEAD LOCATIONS Leads NZL WRK EL Harness Plug (J1) Harness plugs Lead MAIN INVER TER BOARD REMOV ...

  • Lincoln Electric SVM149-A - page 76

    NOTES F-42 F-42 PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric SVM149-A - page 77

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-43 F-43 W ARNING SWITCH REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained person ...

  • Lincoln Electric SVM149-A - page 78

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-44 F-44 FIGURE F.20 – SWITCH L IN C O L N E L E C T R IC PRO-CUT 25 O N O FF PU R G E P O W E R G A S P R E S S U R E T H E R M A L S ...

  • Lincoln Electric SVM149-A - page 79

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-45 F-45 W ARNING F AN REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personne ...

  • Lincoln Electric SVM149-A - page 80

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-46 F-46 FIGURE F.21 – FAN LOCATION L IN C O L N E L E C T R IC PRO-CUT 25 O N O FF PU R G E P O W E R G A S P R E S S U R E T H E R M ...

  • Lincoln Electric SVM149-A - page 81

    PRO-CUT 25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-47 F-47 F AN REMOV AL AND REPLACEMENT (continued) 7. Using a phillips head screwdriver , r emove the four mounting scr ews on the four ...

  • Lincoln Electric SVM149-A - page 82

    RETEST AFTER REP AIR Should a machine under test be rejected for any r eason requiring the r emoval of any mechanical part that could affect the machine’ s electrical characteristics, or if any electrical components are repair ed or replaced, the machine must be retested. Machine Input and Output Input V olts/Hertz Input Current Rated Output 230/ ...

  • Lincoln Electric SVM149-A - page 83

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC G-1 G-1 PRO-CUT 25 ELECTRICAL DIAGRAMS T ABLE OF CONTENTS -ELECTRICAL DIAGRAMS SECTION- ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION G WIRING DIAGRAM - PROCUT 25 . . . ...

  • Lincoln Electric SVM149-A - page 84

    ELEC TRIC AL DIA GRAMS G-2 P RO-CUT 25 WIRING DIA GRAM - PRO-CUT 25 115/230/1/50/60 VAC INPUT CN1 2 1 4 3 5 6 7 8 300uH L1 RL3 10/10W R1 V2 V1 B A 1A/250V F1 RL2 RL2 RL2 AC CP CP A C L1 RL1 RL2 115VAC 230V T1 115V RL1 L1 15VAC 15VAC SAFETY +28VDC SEC GND OVLOAD 115/230 +12VDC AC CP CP AC CN2 6 9 10 2 20 15 16 +15Vrms EV1 NO COM NC 12VDC PS2 PS1 86 ...

  • Lincoln Electric SVM149-A - page 85

    ELEC TRIC AL DIA GRAMS G-3 P RO-CUT 25 WIRING DIA GRAM W/ADDITIONAL INFO pressure Schematic 98056 (SIPC 25) Schematic 99016 ( SPA25) Schematic 98044 Purge Switch (n.o.) Gas Psi . Thermo Safety led Input Power 8 vdc when open for correct pressure RL1 RL3 Auto reconnect card RL1 (control bd mounted) 50hz /60 hz RPM’s 2700/ 3100 amps .13 / .12 runs ...

  • Lincoln Electric SVM149-A - page 86

    ELEC TRIC AL DIA GRAMS G-4 P RO-CUT 25 SCHEMA TIC- CONTROL PRINTED CIRCUIT BO ARD - SHEET 1 G-4 NO TE: This diagr am is for r ef erence only . It may not be accur ate for all machines cov ered b y this manual. Re t ur n t o Se ct io n T OC Re tur n to Se ct io n T OC Re t ur n t o Se ct io n T OC Re tur n to Se ct io n T OC Re t ur n t o Ma ste r T ...

  • Lincoln Electric SVM149-A - page 87

    ELEC TRIC AL DIA GRAMS G-5 P RO-CUT 25 SCHEMA TIC- CONTROL PRINTED CIRCUIT BO ARD - SHEET 2 G-5 NO TE: This diagr am is for r ef erence only . It may not be accur ate for all machines cov ered b y this manual. Re t ur n t o Se ct io n T OC Re tur n to Se ct io n T OC Re t ur n t o Se ct io n T OC Re tur n to Se ct io n T OC Re t ur n t o Ma ste r T ...

  • Lincoln Electric SVM149-A - page 88

    ELEC TRIC AL DIA GRAMS G-6 P RO-CUT 25 SCHEMA TIC- CONTROL PRINTED CIRCUIT BO ARD - SHEET 3 G-6 NO TE: This diagr am is for r ef erence only . It may not be accur ate for all machines cov ered b y this manual. Re t ur n t o Se ct io n T OC Re tur n to Se ct io n T OC Re t ur n t o Se ct io n T OC Re tur n to Se ct io n T OC Re t ur n t o Ma ste r T ...

  • Lincoln Electric SVM149-A - page 89

    NO TE: Lincoln Elec tric assumes no responsibilit y for liablilities resulting fr om board lev el troubleshoo ting. PC Board repair s will inv alidate your factory w arranty . Individual P rint ed Cir cuit Board Component s are not a v aila ble fr om Lincoln Electric . This information is pr o- vided for r efer ence only . Lincoln Elec tric discour ...

  • Lincoln Electric SVM149-A - page 90

    NO TE: Lincoln Elec tric assumes no responsibilit y for liablilities resulting fr om board lev el troubleshoo ting. PC Board repair s will inv alidate your factory w arranty . Individual P rint ed Cir cuit Board Component s are not a v aila ble fr om Lincoln Electric . This information is pr o- vided for r efer ence only . Lincoln Elec tric discour ...

  • Lincoln Electric SVM149-A - page 91

    ELEC TRIC AL DIA GRAMS G-9 P RO-CUT 25 PC 25 T ORCH DET A ILS 5% 75% ELECTRODE SOL. ENERGIZED (surface area is great) Cup “O” rings must be good. electrode is held to the nozzle. COMPRESSED AIR INPUT 20% VERY LITTLE COMPRESSED AIR FLOWING at tip. %= AIR FLOW AIR IS FLOWING & ELECTRODE SOL. IS “ON”. HOLDS ELECTRODE TO NOZZLE ELECTRODE SO ...

  • Lincoln Electric SVM149-A - page 92

    SVM ERROR REPORTING FORM We need to know if there are errors in our manuals. We also value any suggestions as to additional tests or procedures that would make this SVM a better tool for you. If you discover new or different “Problems or Symptoms” that are not covered in the three col- umn troubleshooting chart, please share this information wi ...

Fabricant Lincoln Electric Catégorie Welder

Les documents que nous recevons du fabricant de l'appareilLincoln Electric SVM149-A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lincoln Electric
- manuels d’utilisations SVM149-A
- fiches produit Lincoln Electric
- dépliants
- ou étiquettes-énergie Lincoln Electric SVM149-A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lincoln Electric SVM149-A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lincoln Electric SVM149-A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lincoln Electric SVM149-A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lincoln Electric SVM149-A.

Manuel d’utilisation complet de l’appareil Lincoln Electric SVM149-A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lincoln Electric SVM149-A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lincoln Electric SVM149-A.

Le manuel d’utilisation complet Lincoln Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lincoln Electric SVM149-A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lincoln Electric SVM149-A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLincoln Electric SVM149-A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lincoln Electric SVM149-A - qui devraient nous aider dans les premières étapes lors de l'utilisation Lincoln Electric SVM149-A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lincoln Electric SVM149-A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lincoln Electric SVM149-A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lincoln Electric SVM149-A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lincoln Electric SVM149-A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lincoln Electric SVM149-A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)