    1523, 1524 Thermometer Readout User’ s Guide Rev . 891001_EN ...

  • Fluke 1523 - page 2

    Fluke Corporation, Har t Scientific Division 799 E. Utah V alley Drive • American Fork, UT 84003-9775 • USA Phone: +1.801.763.1600 • T elef ax: +1.801.763.1010 E-mail: suppor t@har tscientic.com www .har tscientific.com Specications subject to change without notice. • Cop yr ight © 2008 • Printed in USA ...

  • Fluke 1523 - page 3

    Limited W arranty & Limitation of Liability Each product from Fluke Corporation, Hart Scientic Division (“Hart”) is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year(s) for the Reference Thermometer . The warranty period begins on the date of the shipment. Parts, p ...

  • Fluke 1523 - page 4

    DA T A, WHETHER ARISING FROM BREACH OF W ARRANTY OR BASED ON CONTRACT , TOR T , RELIANCE OR ANY OTHER THEOR Y . Since some countries or states do not allow limitation of the term of an implied warranty , or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer . ...

  • Fluke 1523 - page 5

    i T able of Contents 1 Befor e Y ou Start ....................................................................... 1 1.1 Introduction ............................................................................................... 1 1.2 Standard Equipment ................................................................................. 1 1.3 Safety I ...

  • Fluke 1523 - page 6

    1 523, 1 524 Ther mometer R eadout ii F igures Figure 1 Clamp-On Ferrite ................................................................................. 6 Figure 2 Input/Output Connections - 1523 ........................................................ 9 Figure 3 Input/Output Connections - 1524 .................................................... ...

  • Fluke 1523 - page 7

    iii T ables T able 1 International Symbols ............................................................................ 4 T able 2 1523 Input/Output Connections ............................................................ 9 T able 3 1524 Input/Output Connections .......................................................... 10 T able 4 1523 Key Functio ...

  • Fluke 1523 - page 8

    ...

  • Fluke 1523 - page 9

    Bef ore Y ou Start Standar d Equipment 1 Bef or e Y ou Start 1 Introduction 1 .1 The Reference Thermometer Readouts (1523, 1524) are designed to be reliable, stable, temperature measur - ing instruments that can be used in the eld or laboratory . They offer accuracy , portability , and speed for near- ly every eld calibration application. The ...

  • Fluke 1523 - page 10

    1 523, 1 524 Ther mometer R eadout Safety Infor mation 2 Safety Inf ormation 1 .3 The Reference Thermometer is designed in accordance with EN 61010-1 {2nd Edition}, and CAN/CSA 22.2 No 61010.1-04. Use this instrument only as specied in this manual, otherwise the protection provided by the instrument may be impaired. A W arning identies condit ...

  • Fluke 1523 - page 11

    Bef ore Y ou Start Safety Infor mation 3 appears damaged or operates abnormally . Protection may be impaired. When in doubt, have the instrument serviced. Always use an isolated R TD or PR T (metal sheath isolated from lead wires).   Make sure the battery door is closed and latched before you operate the reference thermometer .   Do not ...

  • Fluke 1523 - page 12

    1 523, 1 524 Ther mometer R eadout Safety Infor mation 4 T able 1 International Symbols Symbol Description Symbol Descr iption AC (Alternating Current) PE Ground AC-DC Hot Surface (Burn Hazard) Battery Read the User’ s Guide (Important Information) Complies with European Union directives Off DC On Double Insulated Canadian Standards Association E ...

  • Fluke 1523 - page 13

    Bef ore Y ou Start Using Clamp-On F errit es 5 CE Comments 1 .4 EMC Directiv e 1 .4.1 Hart Scientic’ s equipment has been tested to meet the European Electromagnetic Compatibility Directive (EMC Directive, 2004/108/EC ). The Declaration of Conformity for your instrument lists the specic stan- dards to which the unit was tested. The instrume ...

  • Fluke 1523 - page 14

    1 523, 1 524 Ther mometer R eadout Emissions T esting 6 Figure 1 clamp -on ferrite probe cable Clamp-On Ferrite Emissions T esting 1 .6 The instrument fullls the limit requirements for Class B. Low V oltage Dir ective (Saf ety) 1 .7 In order to comply with the European Low V oltage Directive (2006/95/EC), Fluke equipment has been de- signed to m ...

  • Fluke 1523 - page 15

    Bef ore Y ou Start Authorized Ser vice Center s 7 1 .8 A uthorized Ser vice Cent ers Please contact one of the following authorized Service Center to coordinate service on your Fluke product: Fluke Corporation Hart Scientic Division Phone: +1.801.763.1600 Fluke Nederland B.V . Phone: +31-402-675300 Fluke Int'l Corporation - CHINA Phone: +86 ...

  • Fluke 1523 - page 16

    ...

  • Fluke 1523 - page 17

    Quick Start Setup 9 Quic k Star t 2 Set up 2.1 SAVE NEXT HOME ENTER RESET TREND RECALL HOLD STATS ° C ° F SETUP mV RS 232 1 2 V DC 30 V MAX 1 5 2 3 CALIBRATION THERMOMETER READOUT Figure 2 Input/Output Connections - 1523 1523 Input/Output Connections T able 2 No. Name Description 1 Serial Serial interface connector 2 Connector , T1 Sensor Connect ...

  • Fluke 1523 - page 18

    1 523, 1 524 Ther mometer R eadout Setup 10 SAVE NEXT HOME LOG RESET ENTER RECALL HOLD STATS ° C ° F SETUP TREND mV RS 232 1 2 V DC 30 V MAX T 1 T 2 1 5 2 4 CALIBRATION THERMOMETER READOUT Figure 3 Input/Output Connections - 1524 1524 Input/Output Connections T able 3 No Name Description 1 Serial Serial interface connector 2 Connector , T1 Sensor ...

  • Fluke 1523 - page 19

    Quick Start Setup 11 SAVE NEXT HOME LOG RESET ENTER RECALL HOLD STATS ° C ° F SETUP TREND mV RS 232 1 2 V DC 30 V MAX T 1 T 2 1 5 2 4 CALIBRATION THERMOMETER READOUT 1 10 11 4 3 2 5 6 7 8 9 12 Figure 4 Keys ...

  • Fluke 1523 - page 20

    1 523, 1 524 Ther mometer R eadout Setup 12 1523 Key Functions T able 4 No Key Description 1 Power on or off 2 Y ellow Second or Special Function Key 3 T urns the backlight on or off 4 STATS 1st Press: MAX, 2nd Press: MIn, 3rd Press: A VE, 4th Press: STD DEV 5 ° C ° F Units, °C/°F 6 HOLD 1st press - Holds value on screen "-- HOLD --" ...

  • Fluke 1523 - page 21

    Quick Start Setup 13 No Key Description 11 RECALL 1st Press - Enters Recall menu, 2nd Press - Exits Recall Menu 12 NEXT Moves down to next option on screen. 13 + STATS “RESET” - Resets Stats Data 14 + ° C ° F “ Ω mV” - T oggles from °C to Ω or Ω to °C (PRT , thermistor), °C to mV or mV to °C (TC) 15 + HOLD “TREND” - Starts G ...

  • Fluke 1523 - page 22

    1 523, 1 524 Ther mometer R eadout Setup 14 Figure 5 1523 Menu ...

  • Fluke 1523 - page 23

    Quick Start Setup 15 Figure 6 1523 Menu (cont) ...

  • Fluke 1523 - page 24

    1 523, 1 524 Ther mometer R eadout Setup 16 Figure 7 1523 Menu (cont) ...

  • Fluke 1523 - page 25

    Quick Start Setup 17 1524 Key Functions T able 5 No Key Description 1 Power on or off 2 Y ellow Second or Special Function Key 3 T urns the backlight on or off 4 STATS 1st Press: Max, 2nd Press: Min, 3rd Press: Ave, 4th Press: STD DEV 5 ° C ° F Units, °C/°F 6 HOLD 1st press - Holds value on screen "-- HOLD --" across bottom of screen. ...

  • Fluke 1523 - page 26

    1 523, 1 524 Ther mometer R eadout Setup 18 No Key Description 10 ENTER Selects highlighted selection, Saves a new selection. 11 RECALL 1st press - Enters Recall Menu, 2nd press - Exits Recall Menu 12 NEXT Moves down to next option on screen. 13 + STATS “RESET” - Resets Stats Data 14 + ° C ° F “ Ω mV” - T oggles from °C to Ω or Ω t ...

  • Fluke 1523 - page 27

    Quick Start Setup 19 Figure 8 1524 Menu ...

  • Fluke 1523 - page 28

    1 523, 1 524 Ther mometer R eadout Setup 20 Figure 9 1524 Menu (cont) ...

  • Fluke 1523 - page 29

    Quick Start Setup 21 Figure 10 1524 Menu (cont) ...

  • Fluke 1523 - page 30

    1 523, 1 524 Ther mometer R eadout Setup 22 Figure 11 1524 Menu (cont) ...

  • Fluke 1523 - page 31

    Quick Start Setup 23 Figure 12 1524 Menu (cont) ...

  • Fluke 1523 - page 32

    1 523, 1 524 Ther mometer R eadout Specications 24 Figure 13 1524 Menu (cont) Specications 2.2 Specications are based on a one year calibration cycle and apply from 13 °C to 33 °C unless stated otherwise. All specications assume a ve minute warm up period. General Specifications T able 6 Operating T emperatur e † –10 °C to 60 ...

  • Fluke 1523 - page 33

    Quick Start Specications 25 P ow er requir ements 3 AA alkaline batteries 12 V dc universal power supply Size 96 x 200 x 47 mm (3.75 x 7.9 x 1.86 inches) W eight 0.65 kg (1.4 lb) Safety EN 61010-1:2001, CAN/CSA C22.2 No. 61010.1-04 † Environmental conditions for all specifications: 13 °C to 33 °C Millivolt Measurement T able 7 Range Resolut ...

  • Fluke 1523 - page 34

    1 523, 1 524 Ther mometer R eadout Specications 26 Ohms Measurement, Thermistor T able 9 Ohms Range Accur acy ± Ω, 4 W ire 200 Ω to 50 k Ω ± (0.01 % + 0.5 Ω ) 50 k Ω to 500 k Ω ± (0.03 %) T emperature Coefficient ( –10 °C to 13 °C , +33 °C to 60 °C): 0.002 %/°C + 0.1 Ω (0 Ω to 50 k Ω ) 0.06 %/°C + 0.1 Ω (50 k Ω ...

  • Fluke 1523 - page 35

    Quick Start Specications 27 T ype Range Measure Accur acies (ITS-90) L –200 °C to 0 °C 0 °C to 900 °C 0.36 °C 0.23 °C M –20 °C to 0 °C 0 °C to 400 °C 400 °C to 1400 °C 0.26 °C 0.25 °C 0.22 °C N –200 °C to 0 °C 0 °C to 1300 °C 0.72 °C 0.28 °C R –20 °C to 0 °C 0 °C to 500 °C 500 °C to 1750 °C 1.09 °C 0.97 °C 0. ...

  • Fluke 1523 - page 36

    1 523, 1 524 Ther mometer R eadout Specications 28 T emperature, RTD Ranges, T able 11 and Accuracies (ITS-90) Accur acy ± ° C 4 W ire P robe ± 0.011 at –100 °C ± 0.015 at 0 °C ± 0.019 at 100 °C ± 0.023 at 200 °C ± 0.031 at 400 °C ± 0.039 at 600 °C Resolution: 0.001°C (0.001°F) T emperature, Thermistor T able 12 Accur acy ± ° ...

Fabricant Fluke Catégorie Thermometer

Les documents que nous recevons du fabricant de l'appareilFluke 1523 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Fluke
- manuels d’utilisations 1523
- fiches produit Fluke
- dépliants
- ou étiquettes-énergie Fluke 1523
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Fluke 1523.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Fluke 1523, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Fluke 1523. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Fluke 1523.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Fluke 1523, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Fluke 1523 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Fluke 1523.

Le manuel d’utilisation complet Fluke, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Fluke 1523 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Fluke 1523, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFluke 1523 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Fluke 1523 - qui devraient nous aider dans les premières étapes lors de l'utilisation Fluke 1523
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Fluke 1523
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Fluke 1523 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Fluke 1523?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Fluke 1523, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Fluke 1523 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)