Manuel d’utilisation Kohler CFI230G

14 pages 1.53 mb
Télécharger

Aller à la page of 14

Summary
  • Kohler CFI230G - page 1

    CFI230G Indigo Quadrant Enclosur e with integrated Mira Magna Shower System (6 46) Fitting Instructions 1 2 3 4 1 2 3 4 Slide Rail Fixed Head Kohler Daryl Limited Alfred Road, W allasey , W irral, CH4 4 7HY England T el 44 (0)151 6 06 5 000 Fax 44 (0)151 63 8 0303 www .daryl-showers.co.uk E-mail Daryl@daryl-showers.co.uk ...

  • Kohler CFI230G - page 2

    27 CF I230G CU ST OM E R S E RVI CE K ohler Daryl and Kohler Mira Daryl Showering have more than 38 years experience of manufacturing and designing shower enclosures of exceptional quality . For over 80 years, Mira Showers have had the s ame reputation for shower systems. Y our new showering product has been created by these two specialist organisa ...

  • Kohler CFI230G - page 3

    26 CFI2 30G 3 CFI2 30G Intro duction The following pages aim to provide comprehensive installation instructions, plus advice on how to care and maintain your product. W e recommend that the unit is installed by a qualified Plumber or Engineer . Please retain this document for future reference. Note: Due to our desire to always improve our products, ...

  • Kohler CFI230G - page 4

    4 CFI2 30G 25 CFI2 30G COM PON E NTS Lintel Standard T op Caps Parking Block Side Panel Door Splashguard Cap Fixed Roller The unit should be cleaned regularly . Use a non abrasive cleaner (ideally with a pH value of 4 to 8) applied with a soft cloth. Under no circumstances should scourers or power ful detegents be used as these can damage the metal ...

  • Kohler CFI230G - page 5

    24 CFI2 30G 5 CFI2 30G COM PON E NTS 5mm 3mm Slider Rail W ater Delivery System Roller Securing Caps Splashguard Aligning Roller Blanking Cap W ater Delivery T op Caps W ater Delivery W all Jamb & W all Channel Glass Panel x13 A x3 C x5 B x13 3mm 6mm OR Fixed Head W ater Delivery System 2m Pipe and Connector Electrical Cable TR OU B LE S H OO T ...

  • Kohler CFI230G - page 6

    6 CFI2 30G 23 CFI2 30G Remove wall channel fr om jamb and place against mark on wall Adjust wall jamb until glass is parallel to the edge of the tray ‘ A ’ . W hen jamb is vertical mark edge of wall channel on the wall ‘B’ . A B STEP 1 E NCLOSU R E I N ST ALLA TI ON Non W ater Delivery Side only Loosely fit wall c hannel into glass panel ja ...

  • Kohler CFI230G - page 7

    22 CFI2 30G 7 CFI2 30G Check the wall c hannel is vertic al and mark through the 3 holes ‘ A ’ A Drill 3 x 6mm holes Fit plugs Loosely fit scr ews A Seal behind channel and tighten screws A B STEP 5 STEP 6 STEP 7 STEP 8 Slide glass panel into slot in tray “ A ’ and fit jamb into wall channel ‘B’ On the inside of the enclosure. pull the ...

  • Kohler CFI230G - page 8

    8 21 Check glass is vertical. If not remove scr ews, re-drill and re-fit as r equired. Re-fit rubber strip over screws Drill 4 x 3mm holes through jamb into wall channel STEP 10 STEP 11 Fit 4 x screws B Ensure glass panel is vertical STEP 9 Slacken scr ews ‘ A ’ . Push the glass panel into the wall jamb. The glass should be 2mm lower than the t ...

  • Kohler CFI230G - page 9

    Drill 4 x 8mm holes Fit plugs Loosely fit 4 x screws A Carefully lift the panel back into postion Seal behind the wall channel and tighten screws A B A Spot drill through 4 fixing holes in the wall jamb and mark the wall. Only 4 of the 8 holes are using alternate sides ‘ A ’ . Carefully r emove the panel from the tray A B Adjust wall jamb until ...

  • Kohler CFI230G - page 10

    Measure the distance of the glass between the wall jamb and the tray ‘ A ’ . Cut the splashguard to size cutting at the wall jamb end. Fit the splashguard to the bottom of the glass 10 19 CFI2 30G STEP 19 STEP 20 If the any further adjustment is requir ed to make the glass panel vertical turn the 4 screws ‘D’ until the panel is in the corre ...

  • Kohler CFI230G - page 11

    Fit top cap - Water delivery side C C C Fit top cap - Non Water delivery side 18 CFI2 30G 11 CFI2 30G STEP 23 Check top rail is level. Draw ar ound parking block STEP 22 Note: The lintel is supplied as a RH unit. For L H versions loosen the panel clamps and turn them through 180 o Ensure glass panels are parallel to eac h other Loosely fit the park ...

  • Kohler CFI230G - page 12

    Support the weight of the column. Connect the water pipe to the connector from at the top of the column. Caution Support the weight of the column. Plug the electrical c able into the connector on the cable from the W ater Delivery System Caution 12 17 CFI2 30G Check the lintel is level. If adjustment is requir ed turn screw ‘ A ’ on the panel c ...

  • Kohler CFI230G - page 13

    Push top of column into jamb assembly until it locks in place PROCEE D T O STE P 4 7 Support the weight of the column. Connect the water pipe to the connector from at the top of the column. Plug the electrical c able into the connector from the W ater Delivery System at the top of the column. Caution Carefully lift the W ater Delivery System column ...

  • Kohler CFI230G - page 14

    Fit door retainers to both top roller brackets. Caps will ‘click’ and loc k in place Lift the glass door up and slide the rollers onto the lintel Caution Loosen the scr ew fixing the b ottom r oller to the glass with a 3mm allen key Locate other side of glass door panel between the roller and plastic glass guide Caution Whilst supporting the we ...

Fabricant Kohler Catégorie Outdoor Shower

Les documents que nous recevons du fabricant de l'appareilKohler CFI230G peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Kohler
- manuels d’utilisations CFI230G
- fiches produit Kohler
- dépliants
- ou étiquettes-énergie Kohler CFI230G
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Kohler CFI230G.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Kohler CFI230G, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Kohler CFI230G. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Kohler CFI230G.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Kohler CFI230G, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Kohler CFI230G par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Kohler CFI230G.

Le manuel d’utilisation complet Kohler, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Kohler CFI230G - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Kohler CFI230G, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lKohler CFI230G qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Kohler CFI230G - qui devraient nous aider dans les premières étapes lors de l'utilisation Kohler CFI230G
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Kohler CFI230G
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Kohler CFI230G dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Kohler CFI230G?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Kohler CFI230G, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Kohler CFI230G il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)