    For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry.com www.amdry.com WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or exp ...

  • American Dryer Corp. ML-78II - page 2

    Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECA ...

  • American Dryer Corp. ML-78II - page 3

    IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANIN G , ADJUSTIN G , INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRY ...

  • American Dryer Corp. ML-78II - page 4

    WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer. Dryers must not be installed or stored in an area where it ...

  • American Dryer Corp. ML-78II - page 5

    Table of Contents SECTION I IMPORTANT INFORMATION .......................................................................... 3 A. Receiving and Handling ............................................................................................................... 3 B. Safety Precautions ............................................................. ...

  • American Dryer Corp. ML-78II - page 6

    SECTION VI ROUTINE MAINTENANCE ............................................................................ 35 A. Cleaning ................................................................................................................................... 35 B. Adjustments ............................................................................. ...

  • American Dryer Corp. ML-78II - page 7

    3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage. If any damag ...

  • American Dryer Corp. ML-78II - page 8

    4 B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESUL ...

  • American Dryer Corp. ML-78II - page 9

    5 7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location. WARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fir ...

  • American Dryer Corp. ML-78II - page 10

    6 Gas SECTION II SPECIFICA TIONS/COMPONENT IDENTIFICA TION A. SPECIFICA TIONS * For non-reversing models only. ** A minimum of 3/4” pipe must be supplied to the gas inlet for each dryer. NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. BASKET (TUMBLER) DIAMETER 44-1/2” 113 cm BASKET (TUMBL ...

  • American Dryer Corp. ML-78II - page 11

    7 Specifications MLG-78II (Gas) NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. ...

  • American Dryer Corp. ML-78II - page 12

    8 B. COMPONENT IDENTIFICA TION 1. Dryer Front View Illus. No. Description 1 Controls 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Compartment Area (lint screen located behind door) 5 Wire Diagram 6 Data Label and Installation Label (located in the left side panel/wall area behind the control door) ...

  • American Dryer Corp. ML-78II - page 13

    9 2. Dryer Rear View Illus. No. Description 1 Heating Unit 2 Outer Top Area 3* Electric Service Relay Box 4 Basket (tumbler) Bearing Mount Assembly 5 Idler Bearing Mount Assembly 6 Basket (tumbler) (drive) Motor Assembly (for reversing models only) 7 Blower Motor Assembly 8 Dryer Exhaust * Electrical service connections are made in this box. ...

  • American Dryer Corp. ML-78II - page 14

    10 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electri ...

  • American Dryer Corp. ML-78II - page 15

    11 10. The dryer must be installed with provisions for adequate combustion and make-up air supply. CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint build up. B. UNP ACKING/SETTING UP Remove protective shipping material (i.e., plastic wrap, and/or opt ...

  • American Dryer Corp. ML-78II - page 16

    12 C. DR YER ENCLOSURE REQUIREMENTS Bulkheads and partitions must be made of noncombustible materials and must be located a minimum of 12-inches (30.48 cm), 18-inches (45.72 cm) or more is recommended for ease of installation, maintenance, and service above the dryer outer top, except along the front of the dryer which may be partially closed in if ...

  • American Dryer Corp. ML-78II - page 17

    13 D. FRESH AIR SUPPL Y REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected ...

  • American Dryer Corp. ML-78II - page 18

    14 E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, bu ...

  • American Dryer Corp. ML-78II - page 19

    15 IMPORTANT: Exhaust back pressure measured by a manometer in the exhaust duct must be no less than 0 and must not exceed 0.3 inches (0.74 mb) of water column (W.C.). IMPORTANT: Minimum ductwork diameter for horizontal venting is 10-inches (25.4 cm) and for vertical venting the minimum is 12-inches (30.48 cm). NOTE: When the exhaust ductwork passe ...

  • American Dryer Corp. ML-78II - page 20

    16 IMPORTANT: Minimum duct size for a dryer that is vented vertically is 12-inches (30.48 cm) for a round duct or an equivalent of 120 square inches (774.2 square centimeters). THE DUCT SIZE MUST NOT BE REDUCED ANYWHERE DOWNSTREAM OF THE DRYER. IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only be increased to an ...

  • American Dryer Corp. ML-78II - page 21

    17 a. Outside Ductwork Protection 1) To protect the outside end of the horizontal ductwork from the weather, a 90° elbow bent downward should be installed where the exhaust exits the building. If the ductwork travels vertically up through the roof, it should be protected from the weather by using a 180° turn to point the opening downward. In eith ...

  • American Dryer Corp. ML-78II - page 22

    18 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials, ...

  • American Dryer Corp. ML-78II - page 23

    19 2. Electrical Service Specifications IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly . IMPORTANT: The wire s ...

  • American Dryer Corp. ML-78II - page 24

    20 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian El ...

  • American Dryer Corp. ML-78II - page 25

    21 Connect L1 and L2 to the power block and ground to the copper lug located in the rear service box mentioned on the previous page. If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/ pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breake ...

  • American Dryer Corp. ML-78II - page 26

    22 The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes neutral) and ground. Single-phase (1ø) power for the control circuit is done internally to the dryer. No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer. For gas dryers manufactured for operation at 3-phase (3 ...

  • American Dryer Corp. ML-78II - page 27

    23 c. 3-Phase (3 ø ) Wiring Connections (Hookup) - For Reversing Models Only The electrical connections on ALL 3-phase (3 ø ) gas model dryers are made into the rear service box located at the upper left area of the dryer. NOTE: A C I RCU IT SER V I C I NG EACH DR YER MUST BE PROVIDED. If local codes permit, power to a gas dryer can be made by th ...

  • American Dryer Corp. ML-78II - page 28

    24 G . GA S INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirem ...

  • American Dryer Corp. ML-78II - page 29

    25 2. Technical Gas Data a. Gas Specifications b. Gas Connections Inlet connection --- 3/4-inch N.P.T. Inlet supply size --- 3/4-inch N.P.T. (minimum) Btu/hr input -------- 204,000 (51,408 kcal/hr) 1) Natural Gas Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum ...

  • American Dryer Corp. ML-78II - page 30

    26 3. Piping/Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by ...

  • American Dryer Corp. ML-78II - page 31

    27 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.050 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W.C.) pre ...

  • American Dryer Corp. ML-78II - page 32

    28 H. PREP ARA TION FOR OPERA TION/ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ WARNING ,” and “ DIRECTION ” labels attached to the dryer. 2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to the left side p ...

  • American Dryer Corp. ML-78II - page 33

    29 I. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions. 1. Turn on electric power to the dryer. a. Open AL ...

  • American Dryer Corp. ML-78II - page 34

    30 NOTE: To check for proper sail switch operation, open the main door and while holding main door switch plunger in, start the dryer. Dryer should start but heat circuit should not be activated (on). If the heat system is activated, the sail switch is improperly adjusted and must be adjusted by bending the actuator arm of the sail switch toward th ...

  • American Dryer Corp. ML-78II - page 35

    31 b. Dual Timer Models 1) Both dwell (stop) time and basket (tumbler) spin time are adjustable (refer to the illustration on page 37) . 8. Check to insure that ALL setscrews (i.e., basket [tumbler] drive, idler, etc.) are tight. J. PREOPERA TIONAL INSTRUCTIONS 1. To start the dryer... a. Microprocessor Controller (Computer) Dryers... 1) The light ...

  • American Dryer Corp. ML-78II - page 36

    32 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the reseller from whom the ADC equipment was purchased. If the reseller cannot be contacted or is unknown, contact the ADC Service Department for a reseller in your ...

  • American Dryer Corp. ML-78II - page 37

    33 SECTION V W ARRANTY INFORMA TION A. RETURNING WARRANTY CARD(S) 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should you fi ...

  • American Dryer Corp. ML-78II - page 38

    34 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c. Date of dryer installation. d. Date of part failure. e. Specify whether the part(s) being returned is for a replacement, a credit, or a refund. NOTE: If a part is marked fo ...

  • American Dryer Corp. ML-78II - page 39

    35 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent ...

  • American Dryer Corp. ML-78II - page 40

    36 90 DAYS 1. Remove lint from around basket (tumbler), drive motors, and surrounding areas. 2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment. 3. Clean any lint accumulation in and around both the blower and drive motor casing openings. NOTE: To prevent damage, avoid cleaning or touching the hot surface ig ...

  • American Dryer Corp. ML-78II - page 41

    37 SECTION VII REVERSING TIMER SPIN/DWELL ADJUSTMENTS Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer. Both the dwell (stop) time and the basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (as noted in the illus ...

  • American Dryer Corp. ML-78II - page 42

    38 SECTION VIII DA T A LABEL INFORMA TION A. DA T A LABEL When contacting American Dryer Corporation , certain information is required to insure proper service/parts information from ADC . This information is on the data label that is located in the left side panel/wall area behind the control door. When contacting ADC please have the model number ...

  • American Dryer Corp. ML-78II - page 43

    39 THE DATA LABEL 1. MODEL NUMBER The model number is an ADC number, which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer. 3. MANUFACTURING CODE NUMBER The manufacturing code number is a number issued by ADC , which describe ...

  • American Dryer Corp. ML-78II - page 44

    40 1. For Models With Hot Surface Ignition (HSI) Module (CE Version) a. Upon completing installation of the replacement HSI module, reestablish power to the dryer. b. The HSI module’s “red” indicator light will light for up to approximately 5-seconds (self check routine). If the HSI module’s “red” indicator light stays on or flashes con ...

  • American Dryer Corp. ML-78II - page 45

    41 SECTION X BURNER AND BASKET (TUMBLER)/LINT CHAMBER MANUAL RESET HI-LIMIT INSTRUCTIONS IMPOR T ANT MANUAL RESET HI-LIMIT INSTRUCTIONS FOR PHASE 6 MODELS (GAS MODELS ONL Y) This dryer was manufactured with a burner manual reset hi-limit and basket (tumbler)/lint chamber hi-limit thermostat which is monitored by the Phase 6 computer. If either manu ...

  • American Dryer Corp. ML-78II - page 46

    ADC 113106 1 - 08/17/99-25 2 - 09/21/99-25 3 * 05/03/00-25 4* 09/29/00-20 5* 04/10/01-25 6 * 08/15/01-25 ...

Fabricant American Dryer Corp. Catégorie Clothes Dryer

Les documents que nous recevons du fabricant de l'appareilAmerican Dryer Corp. ML-78II peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques American Dryer Corp.
- manuels d’utilisations ML-78II
- fiches produit American Dryer Corp.
- dépliants
- ou étiquettes-énergie American Dryer Corp. ML-78II
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation American Dryer Corp. ML-78II.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation American Dryer Corp. ML-78II, manuels d’entretien, brefs manuels ou manuels de l’utilisateur American Dryer Corp. ML-78II. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit American Dryer Corp. ML-78II.

Manuel d’utilisation complet de l’appareil American Dryer Corp. ML-78II, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser American Dryer Corp. ML-78II par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs American Dryer Corp. ML-78II.

Le manuel d’utilisation complet American Dryer Corp., devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel American Dryer Corp. ML-78II - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières American Dryer Corp. ML-78II, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAmerican Dryer Corp. ML-78II qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil American Dryer Corp. ML-78II - qui devraient nous aider dans les premières étapes lors de l'utilisation American Dryer Corp. ML-78II
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de American Dryer Corp. ML-78II
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service American Dryer Corp. ML-78II dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de American Dryer Corp. ML-78II?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec American Dryer Corp. ML-78II, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec American Dryer Corp. ML-78II il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)