Manuel d’utilisation Ultra Start 600 Series

12 pages 0.76 mb
Télécharger

Aller à la page of 12

Summary
  • Ultra Start 600 Series - page 1

    WWW .UL TRAST ARTERS.COM FCC/ID Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not e ...

  • Ultra Start 600 Series - page 2

    T able of Content s Page 2 Component s 600 Wiring Diagram Page 3 Inst allation Tip s Page 4 Pre-Installation Suggestions Inst allation Suggestions Page 4 Mounting The Module Installing The LED Installing The Program Button Connecting The S t arter Disable Connecting The Dome Light Supervision Under Hood Connections Mounting The Siren Wire Connector ...

  • Ultra Start 600 Series - page 3

    Green Green Green Red Red Blue Blue Blue Black Pink Pink Door Lock Output Door Unlock Output 12vt s Low Current Priority Output (-)500ma Output (-)500ma Output (-)500ma Output (+)500ma Output Programmable - See menu 1, Setting 3 Programmable - See menu 1, Setting 3 Programmable - See menu 1, Setting 3 12vt inverter Output-Low Current Sensor Full - ...

  • Ultra Start 600 Series - page 4

    R ecommended Installation Procedure s Mounting the Module Installing Th e Led Installing Th e Prog ra m Button Connecting Th e Star ter Disable BEFORE ST ARTING INST ALLA TION : - Discuss the optional system features with the customer . - T ake a few minutes to review the installation and owners manuals. - Do a walk around the vehicle and check for ...

  • Ultra Start 600 Series - page 5

    Pink Channel 4 Output Programmable - See menu 2, setting 5. Green (-) Door Input Negative door pin switch input. Blue (-) Hood Input Negative input from hood pin switch. Purple (+) Door Input Positive door pin switch input. Brown (+) Siren Output Positive output for siren. White (+) Park light s Programmable - menu 2, setting 3. Blk/White (+/-) Dom ...

  • Ultra Start 600 Series - page 6

    14 Pin P ower Connector Step 2- Plug-In Th e Module Step 3- Prog ra m, T est And Adjust Th e Shock Sensor T est Th e System When all the connections are done, the control module can be plugged in. Before connecting the control module, make sure the ignition is in the OFF position. Plug in the 6 pin harness then the 14 pin followed by any other conn ...

  • Ultra Start 600 Series - page 7

    Program mode allows you to adjust the settings and options of your system. Y our system has been intelligently designed by installers with years of experience. The system’s default settings do not require any program changes in most cases. However , this system does incorporate a highly advanced programming system that includes 2 menus with numer ...

  • Ultra Start 600 Series - page 8

    Setting 1- Ignition Auto Lock Menu 1 - User Settings Setting 2- Hor n Honk Settings Setting 3- Door Lock Options Setting 4 -Sensor - Enable / Disable Setting 5 - Passive / Active Ar ming Setting 6 - Active / Passive Locks 1 Double Pulse Unlock 1 Flash Single .75 second lock and double unlock pulse 2 3 Second Lock & Unlock 2 Flashes 3 second pul ...

  • Ultra Start 600 Series - page 9

    Setting 1 - Car Finder/ 5th Channel Menu 2- Alar m Settings Setting 2 - Secure V alet Mode Setting 3 - Park Light Output Setting 4 - Hor n Honk Timing Setting 5 - 4th Channel Settings Setting 6 - Car Jack Mode Setting 7 - Hor n/ 5th Channel 1 Car Finder OFF 1 Light Flash Car Finder Mode Disabled *2 Car Finder ON 2 Light Flashes Car Finder Mode Enab ...

  • Ultra Start 600 Series - page 10

    Press Once to Lock the doors and arm the alarm. Hold for Panic Mode. Press a second time and hold for Constant Lock Output. Press Once to Lock and arm the alarm. Hold for Panic Mode. Press a second time and hold for Constant Lock Output. Press once to unlock the doors and disarm the alarm Press and hold for the Tru nk / Aux Output Press once to unl ...

  • Ultra Start 600 Series - page 11

    When the Car Jack Mode is activated the system will start flashing the LED rapidly for five seconds. The park lights a nd siren will then activate once every second for 10 seconds in Countdown Mode. After 10 seconds the alarm will trigger into Full Alarm, the system will no longer respond to the transmitters and the starter disable output will acti ...

  • Ultra Start 600 Series - page 12

    If the alarm system is triggered while armed, the system will ret ain in memory the cause of the trigger . The diagnostics can then be used to determine what the cause of the trigger was. When disarming the alarm, the siren/horn will chirp 3 times instead of the usual 2 times to indicate the alarm had been triggered. The system’ s LED will also f ...

Fabricant Ultra Start Catégorie Automobile Alarm

Les documents que nous recevons du fabricant de l'appareilUltra Start 600 Series peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Ultra Start
- manuels d’utilisations 600 Series
- fiches produit Ultra Start
- dépliants
- ou étiquettes-énergie Ultra Start 600 Series
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Ultra Start 600 Series.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Ultra Start 600 Series, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Ultra Start 600 Series. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Ultra Start 600 Series.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Ultra Start 600 Series, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Ultra Start 600 Series par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Ultra Start 600 Series.

Le manuel d’utilisation complet Ultra Start, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Ultra Start 600 Series - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Ultra Start 600 Series, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lUltra Start 600 Series qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Ultra Start 600 Series - qui devraient nous aider dans les premières étapes lors de l'utilisation Ultra Start 600 Series
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Ultra Start 600 Series
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Ultra Start 600 Series dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Ultra Start 600 Series?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Ultra Start 600 Series, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Ultra Start 600 Series il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (1)

Сергей

После выключения центра,через некоторое время он автоматически включается.В чем причина?