  • Delta Electronics 700VA - page 2

    DELTA DOC CENTER 1 1. IMPORT ANT SAFETY I NSTRUCTI ONS 1-1 UL safet y instruct ion s SA VE THESE INS TRUCTIONS - This manu al contains important in structions for our UPS that should b e followed during installati on and maintenance of the UPS and batte ries. - T o reduce the risk of electric shock, install this UPS in a temperature and humidity co ...

  • Delta Electronics 700VA - page 3

    DELTA DOC CENTER 2 Oth er s afe ty note s: - Exam ine the pac ki ng c ont ai ne r for dam age. Notif y th e ca rri e r imm edi a tely i f da mage is p res ent. - Do not disas s e mble the UPS. - Plug the UPS into a grounded 3-wire AC receptacle only . - Do not use extens ion cords. - Do not operate in area near water or exces si ve humidity . - K e ...

  • Delta Electronics 700VA - page 4

    DELTA DOC CENTER 3 1-2 TUV sa fety instruct ions Pleas e observe the following precautions to ensure personnel safety and reliable equipment operation: - T he sound pressure level at th e operators position according to IEC 704-1:1982 is equal or les s tha n 70dB(A). - Der arbeitsplatzbezog ene Schalldruckpegel dieses Ger ä t es nach DIN 45635 b e ...

  • Delta Electronics 700VA - page 5

    DELTA DOC CENTER 4 - A battery can present a risk o f electric shock and high short circuit current. The following precauti on should be observed when working on ba tteries . • Remove watches, rings or other metal objec ts . • Use tools with insulate d handles . - Eine Batterie kann eine Gefahr eines elektrischen Schlages und sehr g ro β e r K ...

  • Delta Electronics 700VA - page 6

    DELTA DOC CENTER 5 2 INTRODUCTION 2-1 Theory of o peration The main topolog y of th e UPS con sists of by pass p ath, AC-DC conv erter , DC-AC inverter , battery char g er , DC-DC conv erter , control circuit and d etection circuit. Moreover , the intelligent power m anagement software is also optional . The function and efficiency are superior to ...

  • Delta Electronics 700VA - page 7

    DELTA DOC CENTER 6 In case the utility power fail, the AC-DC converter and charger will be off du ty . The DC-DC converter works and conv erts the battery v oltage into DC-BUS voltage. The DC-AC inverter conver ts the DC-BUS voltag e into AC vo ltage. This is so called “ ON-BATTERY m ode”. The auxi lia ry power circuit supplies t he designated ...

  • Delta Electronics 700VA - page 8

    DELTA DOC CENTER 7 Intelli gent design Integrated with a microprocessor , the UPS is able to perform intelligent functions. The UPS triggers over-voltage protection function and tran sfers to “ On- Battery mode ” even when utility voltag e exceeds 300V for 200V-series. In addition, the UPS c an accept larg e voltage variation of 65 V to 138V fo ...

  • Delta Electronics 700VA - page 9

    DELTA DOC CENTER 8 2-3 Annot at ion and symbol The two signs shown on the manual indicating important inst ruction nee d to be followed. Read before Oper ation Maybe Dangerous/Follow I nstructions PROTECTIVE GROUN DING TERMINAL : A terminal which must b e connected to earth ground prior t o making any othe r connection to the equipment. This symbol ...

  • Delta Electronics 700VA - page 10

    DELTA DOC CENTER 9 Fig 2-1.2 Front Panel for 2KV A or 3K V A 2-5 O PERA TIO N P ANEL Fig 2-2 Operation Panel OPERA TION P ANEL A. Butt on: 1. 1/TEST : T he button is used for turning on the UPS , it also can perform the test function in “ ON-LINE mode ”. In backup mode, this button c an turn off the buzzer for s il ence. 2. 0: The button is use ...

  • Delta Electronics 700VA - page 11

    DELTA DOC CENTER 10 2. Line: The LED indicates the condition of UPS input line. I f the input v oltage is too low , too high or out of frequency this LED wil l flash. Wh en line i s blackout or ultra high voltage (>150V ac for 100-series, >300V ac for 200-series), thi s LED will lig ht off. 3. ON Line: The UPS is runni ng in “ ON-LINE mod e ...

  • Delta Electronics 700VA - page 12

    DELTA DOC CENTER 11 2.6 RE AR P ANEL The rear panel is expl ained as follows: (Pleas e ref er to fig 2-3, 2-4) Fig 2-3 700V A, 1KV A Fig 2-4 2KV A, 3KV A 1. OUTPUT RECEP T ACLES or T ERMINAL : The UPS supplies AC p ower to the load via these receptacles and t erminal. There are several kinds of outpu t connector for different dem ands , like: NEMA ...

  • Delta Electronics 700VA - page 13

    DELTA DOC CENTER 12 2. I/P BREAKER : This i s used to prevent high input current from the UPS. 3. INPUT SOCKET or TER MINAL : AC input utility pow er supplies to the UPS via the s ocket or t erminal. 4. SNMP SLOT : A S NMP adapt er can be plug ged in t his port f or mana ging UPS on network. 5. TVS S (T rans ient V oltage Surge S urppressor) (RJ-45 ...

  • Delta Electronics 700VA - page 14

    DELTA DOC CENTER 13 3. INS T ALLA TION 3-1 Unpacking z Please read this us e r manual before ins talling the UPS. z This UPS contains batte ries which are potentially hazardou s to user , even when the UPS is not connecte d to the uti lit y power . z Before unpacking the UPS, check the packing box. If there are any visible damage, cont act ...

  • Delta Electronics 700VA - page 15

    DELTA DOC CENTER 14 (2) Plug the other end of the power cord into a two-pole, three-wire , grounding re cept acl e only . A void using ext e nsi on cords and a dapter plug. {  If input type i s te r minal type (1) Be sure to utilize UL 1015#12 A WG WIRE for GES302N1 1XX model and UL1015#10 A W G WIRE f or GES202N1 1XX mode l for power c onnectio ...

  • Delta Electronics 700VA - page 16

    DELTA DOC CENTER 15 3. Charging t he battery {  The battery char ger of the UPS automatically ch arg es the battery whenev er the power cord of UPS is conne cted to a acce ptabl e utility power . {  When UPS i s running fo r the first time, char ge the UPS for at least 6 hours to en sure batteries ins ide are fully charg ed before operation. ...

  • Delta Electronics 700VA - page 17

    DELTA DOC CENTER 16 {  T urn on the e quipme nt connect ed t o the UPS. {  Caution: Do not connect a laser print e r t o the UPS. {  Caution: Do not connect the UPS from g enertor . 5. Connecting the RS-232/Dry contact {  Connect the interface sig nal cable between the RS-232 / Dry contact por t on th e rear panel of UPS and COM1 or COM ...

  • Delta Electronics 700VA - page 18

    DELTA DOC CENTER 17 Fig 3-4.2 UPS Co nnecti on for 2KV A or 3KV A: (1) RS-232/Dry c ontact c able. (2) Provide s power to PC. (3) Connected to ut ility power . (3) (2) (1) SHEET 18 TO 19 ...

  • Delta Electronics 700VA - page 19

    DELTA DOC CENTER 18 4. OPERA TION 4-1 Cold start w hen utility is not present Even when there i s no utility power , y ou can still turn on the UPS. Just press the 1/ TEST button and hold for one second, the UPS will start up after you he ar a “bee” . The battery LED and on-battery LED will lig ht on and the UPS runs on “ ON-BA TTER Y mo de ? ...

  • Delta Electronics 700VA - page 20

    DELTA DOC CENTER 19 4-4 UPS self-t est If press the 1/TE ST button when the UPS is in “ ON-LINE mo de ” , it will make the UPS shif t to “ ON-BA TTER Y mode” and autom atically per form a self-test f or about 10 seconds. (Shown a s fig 4-4. ) The self-test fun ction will chec k the condition of the bat tery . After self-test is fin ish ed a ...

  • Delta Electronics 700VA - page 21

    DELTA DOC CENTER 20 {  BA TT ER Y REPLACE: T his LED function i s to alert u ser that the batteries should be replac ed. When th e microproce ssor in th e UPS detects a b attery fau lt, the UP S alarm w ill g ive out three beeps. Each beep la sts for 0.5 seconds and interrupted by an interval of 0.5 seconds. After the initial 3 beeps, the alarm ...

  • Delta Electronics 700VA - page 22

    DELTA DOC CENTER 21 4-7 UPS internal fault If the following conditions occur , the UPS fails. At this time the UPS will transfer to “ BYP ASS mode ”. The bypass LED and fault L ED will light on and al arm continuously . If utility is too low or too high the UPS output wi ll be disabled. For fault messages, please refer to the troubleshoot ing ( ...

  • Delta Electronics 700VA - page 23

    DELTA DOC CENTER 22 5. MAINTENANCE z Normally , the life of b attery is 3 y ears. But extreme operating condition and environment ma y s horten its lif e-span. z T o re place batterie s , contact qualifie d personnel . z Whe n UPS has been unu sed for a period of tim e, the batteries will dischar ge slightly . It is re comm ended to c harg ...

  • Delta Electronics 700VA - page 24

    DELTA DOC CENTER 23 6. PLACEM ENT T o stably install th e UPS , the 2,3KV A must add stand s to support themselves. The insta llat ion met hod is as shown below: Fig 6-1 Erect the UPS with supporting stands SHEET 24 TO 25 ...

  • Delta Electronics 700VA - page 25

    DELTA DOC CENTER 24 7. TROUBLESHOOTING Problem Po ssib le Ca us e Solution ON/TEST button is not pus hed. Press the 1/TEST button to turn on the UPS. (Refer section 4 to turn on the UPS.) Ba tte ry lo w sh ut d ow n and utility is abs e nt. W ait ing f or line rec overy . The rear panel input c ircuit breaker is tripped. (Button is tripped out) 1. ...

  • Delta Electronics 700VA - page 26

    DELTA DOC CENTER 25 The exhaust fans and v entila tion grills ma y be obs tructe d. Choose a w ell-ventilated area to position your UPS to allow adequate dis sipati on of heat . UPS ov er tempe rature. The environment t emperature exceeds 40 o C (104 o F). Position your UPS in cooler area. “F AUL T”LED lights on , alarm beep s UPS failure. Call ...

  • Delta Electronics 700VA - page 27

    DELTA DOC CENTER 26 8. COMMUNIC A TION INTERF ACE The UPS provides RS-232 and Dry contact protocols in on e D-sub 9 c onnector . Using proper UPS management software and cable, the UPS can be managed over LAN/intranet/internet en vironment. The pin assignment of th e D-sub 9 connector is defined a s f ollows : ASSIGN MENT DESCRIPTION PIN RS-232 Dry ...

  • Delta Electronics 700VA - page 28

    DELTA DOC CENTER 27 The RS-232 communication port provides the f oll owing functions : 1) Monitori ng charger st atus 2) Monitoring battery status a nd condition 3) Monitori ng inverter st atus 4) Monitori ng UPS status 5) Monitoring the utilit y s tat us 6) Pro viding the power switch functi on for computer to turn on/off th e utility on schedule ...

  • Delta Electronics 700VA - page 29

    DELTA DOC CENTER 28 Its major f uncti ons normally some or all of following:  T o broa dcast a warning when power f ail s.  T o c lose the files before the ba tter y is e xhausted.  T o t urn off the UPS computers. Some computers may have a special connector to link this communicat ion port, or require a special plug-in card , or ...

  • Delta Electronics 700VA - page 30

    DELTA DOC CENTER 29 T echnical specifications Model GES7 01N GES102N GES2 02N GES302N Capa city 700V A/56 0W 1KV A/800W 2KV A/1600W 3KV A/2400W Rated V olta ge 100V ,1 10V ,120V 200V ,208V ,220V ,230V ,240V V oltage Rang e 80V ∼ 13 8V(Fu ll Load ) ; 65V~ 80V(70% Lo ad) 160V ∼ 275V(Fu ll Load ) ; 130V ~160V (70% Load ) Fr e que nc y 50Hz/60 ...

  • Delta Electronics 700VA - page 31

    SHEET 31 TO END ...

Fabricant Delta Electronics Catégorie Power Supply

Les documents que nous recevons du fabricant de l'appareilDelta Electronics 700VA peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Delta Electronics
- manuels d’utilisations 700VA
- fiches produit Delta Electronics
- dépliants
- ou étiquettes-énergie Delta Electronics 700VA
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Delta Electronics 700VA.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Delta Electronics 700VA, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Delta Electronics 700VA. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Delta Electronics 700VA.

Manuel d’utilisation complet de l’appareil Delta Electronics 700VA, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Delta Electronics 700VA par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Delta Electronics 700VA.

Le manuel d’utilisation complet Delta Electronics, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Delta Electronics 700VA - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Delta Electronics 700VA, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDelta Electronics 700VA qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Delta Electronics 700VA - qui devraient nous aider dans les premières étapes lors de l'utilisation Delta Electronics 700VA
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Delta Electronics 700VA
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Delta Electronics 700VA dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Delta Electronics 700VA?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Delta Electronics 700VA, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Delta Electronics 700VA il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)