    For more information, visit www .fmiproducts.com UNVENTED (VENT -FREE) FIREB OX OWNER’S OPERA TION AND INST ALLA TION MANU AL MODEL FBPS, FGPN AND FGPN-LS 36" Peninsula Heat-Circulating Firebox W ARNING: If the information in these instructions is not followed exactly , a re or explosion may result causing property damage, personal injury ...

  • FMI FGPN - page 2

    www .fmiproducts.com 105163-01E 2 SAFETY W ARNING: Improper installation, adjustment, al - teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in - stallation and operational procedures. For assistance or additional information consult a qualied installer , service agency or the gas supplier . W ...

  • FMI FGPN - page 3

    www .fmiproducts.com 105163-01E 3 W ARNING: Do not use a blow - er insert, heat exchanger insert or o ther acce ssor y no t app rove d for use with this rebox. Do not al low fans t o bl ow d ire ctly into the rebo x. Av oid any drafts that alter burner ame patterns. Ceiling fans can create drafts that alter burner ame patterns. Altered ...

  • FMI FGPN - page 4

    www .fmiproducts.com 105163-01E 4 LOCAL CODES Install and use rebox with care. Follow all local codes. In the absence of local codes, use the latest edition of The Natio nal Fuel Gas Code ANS Z223.1 / NFP A 54 *. Firebox must be electrically grounded in accordance with the National Electrical Code, ANS/NFP A70 (latest edition). *Available from: ...

  • FMI FGPN - page 5

    www .fmiproducts.com 105163-01E 5 Figure 1 - Peninsula (Three-Sided) Firebox 4 1 / 2 " 4 3 / 4 " 33 3 / 4 " 3 5 / 8 " 4" 4" 1 1 / 4 " 1/2" 5/8" 19 1 / 2 " 40" 18 1 / 2 " 9 1 / 8 " 36 1 / 4 " 1 3 / 4 " 4" 1 1 / 2 " 24" 36 1 / 2 " 3" TYP . 42 1 / 2 &qu ...

  • FMI FGPN - page 6

    www .fmiproducts.com 105163-01E 6 AIR FOR COMB USTION AND VENTILA TION W ARNING: This heater shall not be installed in a room or space unless the required vol - ume of indoor combustion air is provided by the method de - scribed in the National Fuel Gas Code, ANSI Z223.1/NFP A 54, the International Fuel Gas Code, or applicable loca l codes. Read th ...

  • FMI FGPN - page 7

    www .fmiproducts.com 105163-01E 7 DETERMINING FRESH-AIR FLOW FOR FIREBOX LOCA TION Determining if Y ou Have a Conned or Unconned Space Use this work sheet to determine if you have a conned or unconned space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills ...

  • FMI FGPN - page 8

    www .fmiproducts.com 105163-01E 8 AIR FOR COMB USTION AND VENTILA TION Continued Figure 3 - V entilation Air from Inside Building Or Remove Door into Adjoining Room, Option 2 V e ntilation Grills Into Adjoining Room, Option 1 4" Figure 4 - V entilation Air from Outdoors Outlet Air V e ntilated Attic Outlet Air Inlet Air Inlet Air V e ntilated ...

  • FMI FGPN - page 9

    www .fmiproducts.com 105163-01E 9 CAUTION: Log heaters in - st all ed in t hi s  re box cr eat e w ar m air currents. These currents move heat to wall surfaces next to re - b ox . In st al li ng  re bo x ne xt t o vi ny l or cloth wall coverings or operat - ing rebox where impurities (such as , b ut no t li mi ted to , tob acc o smoke, ...

  • FMI FGPN - page 10

    www .fmiproducts.com 105163-01E 10 INST ALLA TION Continued Mantel Clearances for Built-In Installation If placing custom mantel above built-in re - box, you must meet the minimum allowable clearance between mantel shelf and top of rebox opening shown in Figure 7. These are the minimum allowable mantel clearances for a safe installation. Use ...

  • FMI FGPN - page 11

    www .fmiproducts.com 105163-01E 11 INST ALLA TION Continued 1 1 / 2 " Max. 3/8" Max. 4" 8" Min. from adjacent wall to fireplace opening SAFE ZONE Combustible material must not overlap more than 3/8" onto black metal front face. Nailing Flange Drywall Figure 9 - Framing for Built-In Firebox Installation, T op V iew Min. from ...

  • FMI FGPN - page 12

    www .fmiproducts.com 105163-01E 12 INST ALLA TION Continued CAUTION: Do not use exces- sive force to remove the knock - ou t. T oo much f orc e ma y dama ge the rebrick concrete insert. A manual shutoff valve, CSA certied and complying with the National Fuel Gas code, ANS Z223.1/NFP A 54 , must be included within 6' of the vent-free r ...

  • FMI FGPN - page 13

    www .fmiproducts.com 105163-01E 13 Prepare incoming black iron gas line with T eon tape or pipe joint com poun d (chec k with local codes as to the use of T eon tape). Com - pounds used on threaded joints of gas piping shall be resistant to the action of propane/LP and shoul d be appl ied light ly to ensu re excess sealant does not enter the ...

  • FMI FGPN - page 14

    www .fmiproducts.com 105163-01E 14 INST ALLA TION Continued Note: A 120V supply connection to the leads to the receptacle must be provided for use with the optional blower kit whether installed during or after initial rebox installation. Y ou may not be able to install a supply connection after the nal installation is completed. HEA T DEFLECT ...

  • FMI FGPN - page 15

    www .fmiproducts.com 105163-01E 15 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty . Contact authorized dealers of this product. If they can’t supply original replacement part(s), call FMI PRODUCTS, LLC at 1-866-328-4537. When calling, have ready: • your na ...

  • FMI FGPN - page 16

    www .fmiproducts.com 105163-01E 16 P ARTS MODELS FBPS, FGPN AND FGPN-LS **These items are used on both sides of fireplace. 8** 15 17** 17** 17** 7-1 7-2 7-3 2 17** 1 1 ** 17** 17 12 6 16 13 10** 5** 17 17 15 16 4 16 16 6 16 15 17** 17** 18 Ty p. Ty p. Ty p. 8** 17** 17** 9** 14 16 1 3 ...

  • FMI FGPN - page 17

    www .fmiproducts.com 105163-01E 17 P ARTS MODELS FBPS, FGPN AND FGPN-LS This list contains replaceable parts used in your rebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 *** Firebox Assembly 1 2 *** Firebox Bottom 1 3 *** Firebox T op 1 4 23982 T ...

  • FMI FGPN - page 18

    www .fmiproducts.com 105163-01E 18 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________ ...

  • FMI FGPN - page 19

    www .fmiproducts.com 105163-01E 19 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________ ...

  • FMI FGPN - page 20

    105163-01 Rev . E 01/10 WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES New Products Standard Warranty: FM I PR O DU CT S, LL C wa rr an ts th is ne w p ro du ct an d an y pa rt s th er eo f t o be fr ee fr om de fe c ts i n ma te r ia l a n d wo r k ma ns hi p f or a p er io d o f t wo ( 2 ) y ea r s fr om t he da te o f  rs t ...

Fabricant FMI Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilFMI FGPN peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques FMI
- manuels d’utilisations FGPN
- fiches produit FMI
- dépliants
- ou étiquettes-énergie FMI FGPN
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation FMI FGPN.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation FMI FGPN, manuels d’entretien, brefs manuels ou manuels de l’utilisateur FMI FGPN. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit FMI FGPN.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil FMI FGPN, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser FMI FGPN par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs FMI FGPN.

Le manuel d’utilisation complet FMI, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel FMI FGPN - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières FMI FGPN, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFMI FGPN qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil FMI FGPN - qui devraient nous aider dans les premières étapes lors de l'utilisation FMI FGPN
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de FMI FGPN
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service FMI FGPN dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de FMI FGPN?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec FMI FGPN, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec FMI FGPN il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)