Manuel d’utilisation CFM A125

32 pages 3.83 mb
Télécharger

Aller à la page of 32

Summary
  • CFM A125 - page 1

    DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from your neighbor ’s phone. Follow the gas su ...

  • CFM A125 - page 2

    2 Gas Fireplace Insert 10002964 T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace insert. IMPORT ANT - Read all instructions and warnings carefully before starting installation. Failure to follow these instructio ...

  • CFM A125 - page 3

    3 Gas Fireplace Insert 10002964 This gas appliance should be installed by a qualified installer , preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For U.S. Installations follow local codes and/or the current National Fuel Gas ...

  • CFM A125 - page 4

    4 Gas Fireplace Insert 10002964 A B C D J E F G H U V S T R Q 4“ P O N M L K 2964 A125_132 specs 10/06 Maintain 1” Clear- ance to ‘B’ V ent Zero Clearance Kit Gas Inlet Knock-out Air Inlet Channel R - Fireplace Opening Width Q - Fireplace Opening Height S - Depth of Insert T - Firebox Width at Insert Depth (S) U - Firebox Depth at Insert Ba ...

  • CFM A125 - page 5

    5 Gas Fireplace Insert 10002964 Locating Y our Gas Fireplace Insert with Zero Clearance Kit C D B E A F X X X FP1249a locating DV unit with zero clearance kit 4/03 FP1249 a Fig. 1 Locating unit with zero clearance kit. A) Flat on wall B) Cross corner C) Island D) *Room divider E) *Flat on wall corner F) Chase installation NOTE: (Fig. 1) * When you ...

  • CFM A125 - page 6

    6 Gas Fireplace Insert 10002964 Combustion Air It is very important that an adequate air supply is available when the unit is being operated. Since most homes of today are tightly sealed and insulated, addi- tional make-up air is usually necessary . This fireplace has been designed to operate by drawing air in from the front and outer perimeters o ...

  • CFM A125 - page 7

    7 Gas Fireplace Insert 10002964 CFM106 T ypical Gas Line Connection 9-29-00 1/2” Gas Supply 1/2” x 3/8” Reducer 3/8” Nipple 3/8” x 3/8” Shut Off V alve 3/8” Nipple 3/8” Union 3/8” Nipple CFM106 Fig. 4 T ypical gas line installation. When using copper or flex connector , use only approved fittings. Always provide a union when usi ...

  • CFM A125 - page 8

    8 Gas Fireplace Insert 10002964    Leveling Bar Set Screws FP1658 Fig. 8 Adjust leveling bar on A132 only . 2' Min. 2' (610mm) Min. 3' Min. 0 To 10' 3' (914mm) Min. 0 To 10' AC246 4/1/96  Reference Point (3m) Fig. 9 Example of the 2', 3', ...

  • CFM A125 - page 9

    9 Gas Fireplace Insert 10002964 Common Flue Installations In some areas it is possible to vent more than one gas fireplace into the same flue. Y ou must ensure the flue being shared has the proper capacity to handle both fireplaces. Check installation codes for venting capacity information. As always it is best to check with the authority havin ...

  • CFM A125 - page 10

    10 Gas Fireplace Insert 10002964 Fan Kit Installation 1 15 V olt, 60 Hz. 56W The fan kit includes the following: fan, temperature sensor , speed control and a 6 ft. cord. The following explains how to start and set the fan for automatic operation. 1. Plug in the electrical cord. 2. Start gas fire - see lighting procedures. 3. T urn on fan speed co ...

  • CFM A125 - page 11

    1 1 Gas Fireplace Insert 10002964 Operating Instructions General Glass Information Only ceramic glass approved by CFM Cor- poration may be used for replacement on this unit. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. 3. Under no circumstances should this appliance be operat ...

  • CFM A125 - page 12

    12 Gas Fireplace Insert 10002964     Left Rear Log N15 Front Left Log N13 Right Rear Log N16 Front Right Log N14 Ember Material LG479 Figure 17 A125     Front Left Log N19 Left Rear Log N17 Front Right Log N20 Right Rear Log N18 LG481 E ...

  • CFM A125 - page 13

    13 Gas Fireplace Insert 10002964 First Firing Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge them- selves of this air . Once the purging is complete, the pilot and burner will light and operate as indicated in the instruction manual ...

  • CFM A125 - page 14

    14 Gas Fireplace Insert 10002964 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to " OFF ". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on to Step 4. For RN/RP ...

  • CFM A125 - page 15

    15 Gas Fireplace Insert 10002964 W ARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off electrode at pilot. pilot and push the red button again. If pilot will not light - check ...

  • CFM A125 - page 16

    16 Gas Fireplace Insert 10002964 Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Depressing Piezo — 1/8" Gap To Pilot Hood Needed. All Wiring Connections Replace Piezo Ignitor For Air In The Lines Thermopile Needs A Minimum 325mv. Adjust Pilot ...

  • CFM A125 - page 17

    17 Gas Fireplace Insert 10002964 Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual. Always h ...

  • CFM A125 - page 18

    18 Gas Fireplace Insert 10002964 1 A125 1a 1b 1c 1d 3 2 4 5 9a/b 8a/b 19 14 16 18 10a/b 18 17 1 1a/b 13 14 15 20          23a/b 21 22a/b 24 25 26 27 28 30 29 31 32 33 35 34 2964 A125/132 parts 1 1/06 1a 1b 1c 1d 1 A132 CFM Corporation reserves the right to make changes in design, mat ...

  • CFM A125 - page 19

    19 Gas Fireplace Insert 10002964 Ref. Description A125 A132 A125, A132 Gas Insert 9a. Orifice Pilot PSE - Nat. 10001822 10001822 9b. Orifice Pilot PSE - Prop. 10001823 10001823 10a. Pilot Assembly SIT T op Convertible - Nat. 10002389 10002389 10b. Pilot Assembly SIT T op Convertible - Prop. 10002390 10002390 1 1a. Pilot Assembly PSE - Nat. 100017 ...

  • CFM A125 - page 20

    20 Gas Fireplace Insert 10002964 Ceramic Refractory Optional for A125 and A132 Model Description RHE25CR Ceramic Firebox Liner 1. Remove front glass (Refer to Glass Frame Removal section) 2. Remove logs from unit. Logs may be hot! 3. Remove refractory from packaging. Refractory are fragile and must be handled with care. Where at all possible, two h ...

  • CFM A125 - page 21

    21 Gas Fireplace Insert 10002964 5. Remove the two screws that hold the top brass trim. 6. Install the two brackets to the studs in the bottom of the top channel. Use the nuts supplied with top trim channel. A flat louvre kit OR a bay window kit need to be chosen to complete the installation. 4 2 3 4 1 6 6 5  FP1289 RHE trim parts 2/03 RHE25SSP ...

  • CFM A125 - page 22

    22 Gas Fireplace Insert 10002964 1 2 3 4 5 FP1293 HE25FP parts 2/03 FP1293 HE25FP Replacement Parts CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. IMPORT ANT : Only trim panel assemblies approved by CFM Corporation can be used on th ...

  • CFM A125 - page 23

    23 Gas Fireplace Insert 10002964 KT210 Install bay front 3/19/01 djt KT210a Fig. 34 Hang the window grille or the steel frame onto the lower tabs of the hanging brackets. KT21 1a Install bay front upper grille 2/4/03 djt KT21 1a Fig. 35 Engage the slots in the upper grille top louvre with the upper tabs of the hanging brackets. KT212a Atta ...

  • CFM A125 - page 24

    24 Gas Fireplace Insert 10002964 A4 Riser Kits For use with A125 1. Install the unit according to Homeowner ’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the trim. 4. Install the riser at the bottom of the trim. (Fig. 37) 5. Fasten the trim with the same two (2) screws re- mov ...

  • CFM A125 - page 25

    25 Gas Fireplace Insert 10002964 4. Install the trim top deflector and fasten it (will hold the inner top piece). Use two (2) screws to assemble them. 5. Install trim channels (left and right sides). Use two (2) screws to assemble each piece. 6. Slide on the trim top channel and fasten it from the back side. 7. Remove ALL plastic protective coveri ...

  • CFM A125 - page 26

    26 Gas Fireplace Insert 10002964 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. IMPORT ANT : Only trim panel assemblies ap- proved by CFM Corporation can be used on these products. ALL repair parts will be available from your local dea ...

  • CFM A125 - page 27

    27 Gas Fireplace Insert 10002964 A4 Riser Kits For use with A125 1. Install the unit according to Homeowner ’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the trim. 4. Install the riser at the bottom of the trim. (Fig. 56) 5. Fasten the trim with the same two (2) screws re- mov ...

  • CFM A125 - page 28

    28 Gas Fireplace Insert 10002964 ...

  • CFM A125 - page 29

    29 Gas Fireplace Insert 10002964 ...

  • CFM A125 - page 30

    30 Gas Fireplace Insert 10002964 ...

  • CFM A125 - page 31

    31 Gas Fireplace Insert 10002964 BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations. EXTE ...

  • CFM A125 - page 32

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation ...

Fabricant CFM Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilCFM A125 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques CFM
- manuels d’utilisations A125
- fiches produit CFM
- dépliants
- ou étiquettes-énergie CFM A125
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation CFM A125.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation CFM A125, manuels d’entretien, brefs manuels ou manuels de l’utilisateur CFM A125. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit CFM A125.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil CFM A125, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser CFM A125 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs CFM A125.

Le manuel d’utilisation complet CFM, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel CFM A125 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières CFM A125, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCFM A125 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil CFM A125 - qui devraient nous aider dans les premières étapes lors de l'utilisation CFM A125
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de CFM A125
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service CFM A125 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de CFM A125?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec CFM A125, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec CFM A125 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)