    ® PN 2063508 January 2003 © 2003 Fluke C orpor ation. Al l rig hts reserv ed. P rinted in Chin a. All produc t nam es are tr adem arks of the ir res pective c ompa nies. 12 Multimete r Users Manual ...

  • Fluke PN 2063508 - page 2

    i Table of Contents Title Page READ FIRST: SAFETY INFORMATION .................................................... 1 SYMBOLS .................................................................................................. 2 DISPLAY .................................................................................................... 3 OPERATING FEA ...

  • Fluke PN 2063508 - page 3

    12 Multimeter Users M anual ii Recording Min imum and Max imum Readi ng with El apsed Tim e ............ 19 Capturing Con tinuity Interm ittents with Cont inuity Capture  .................. 21 TURNING BEEPER OFF............................................................................ 23 MAINTENANCE............................................. ...

  • Fluke PN 2063508 - page 4

    1 READ FIRST: SAFETY INFORMATION This meter has been des igned a nd tested i n acc ordance wit h IEC Publicat ion 1010 . To ensure that th e meter is used s afely, follow all s afety an d operating i nstruc tions in this manual. If th e meter is n ot used as desc ribed in th is manua l, the s afety features of the meter might be im paired. W Warnin ...

  • Fluke PN 2063508 - page 5

    12 Multimeter Users Manual 2 SYMBOLS The followi ng inter nationa l elec trical sy mbols are us ed in t his m anual: W Important Safe ty Informat ion in Manual ∅ Not Applic able to I dentifie d Model B AC F DC G Diode E Capacitor J Ground T Double Insulat ion ...

  • Fluke PN 2063508 - page 6

    12 Multimeter DISPL AY 3 DISPLAY Figure 1. D isplay ...

  • Fluke PN 2063508 - page 7

    12 Multimeter Users Manual 4 OPERATING FEATURES Figure 2. Operating Features ...

  • Fluke PN 2063508 - page 8

    12 Multimeter STAND BY MOD E 5 STANDBY MOD E In standby m ode, the dis play goes blank to preserv e battery life. Th e meter beeps and enters Standby if it is O N but inac tive f or more than 45 minutes . Press any pushbu tton to resume op eration. Standby is n ot allowe d if the met er is in the MIN M AX mode. INPUT RANGES The input r ange determ ...

  • Fluke PN 2063508 - page 9

    12 Multimeter Users Manual 6 Autoranging The meter defa ults to autor ange w hen you tur n it on. I n autora nge, the m eter selec ts the range autom atic ally. Manually Selecting a Range The meter als o has a m anual ran ge mode. In m anual rang e, you s elect and lock the meter in a ran ge. To manua lly s elect a r ange: 1. Press [ V ]. The meter ...

  • Fluke PN 2063508 - page 10

    12 Multimeter MEASURI NG VOLTAGE 7 MEASURING VOLTAGE 1. Inser t the test l eads i n the ja cks. 2. To select a voltage function, pu t the s lide-s witch in t he middle position. Se e Figure 3. To toggle betw een dc and ac, pr ess [ g ]. 3. Touch the probes to th e test po ints, and r ead the display . The meter beeps an Overload Aler t™ when O L ...

  • Fluke PN 2063508 - page 11

    12 Multimeter Users Manual 8 Figure 3. Measuring Vo ltage ...

  • Fluke PN 2063508 - page 12

    12 Multimeter TESTI NG CONTINUITY A ND MEAS URI NG RESISTANCE 9 TESTING CONTINUITY AND M EASURING RESISTANC E 1. Inser t the test l eads i n the ja cks, and turn off power t o the circ uit under test. External volt age ac ross the c omponents c auses inv alid readin gs. 2. Put the slide-switch i n the c ontinuity/o hms pos ition (Figur e 4). To tog ...

  • Fluke PN 2063508 - page 13

    12 Multimeter Users Manual 10 Figure 4. Continuity and Res istance Measurements ...

  • Fluke PN 2063508 - page 14

    12 Multimeter TESTING DIOD ES 11 TESTING DIOD ES 1. Inser t the test l eads i n the ja cks. 2. Put the slide-switch i n the c ontinuity/o hms pos ition. The m eter selec ts eit her the continuity /diode ( R G ) or ohm s ( e ) f unction. If ohms is select ed, pres s [ g ] to toggle to th e conti nuity/diode functi on. To to ggle the beeper on or off ...

  • Fluke PN 2063508 - page 15

    12 Multimeter Users Manual 12 Figure 5. Test ing Diodes ...

  • Fluke PN 2063508 - page 16

    12 Multimeter VCHEK A N D HOW TO USE IT 13 VCHEK AND HO W TO USE IT i is a subs et of the con tinuity /ohms func tion. In i , th e meter is designed t o automatical ly display an ac or dc volt age when the meter detec ts a vo ltage gre ater in magnitude th an about 4.5 V and the meter is not in the manual range m ode. THIS WILL NOT HARM THE METER. ...

  • Fluke PN 2063508 - page 17

    12 Multimeter Users Manual 14 Use i only on power s uppli es and other power sourc es that hav e a low output impedance. D o not us e i to m easure volt age in e lectronic c ircuitry u nless a 2 k e load will not damage the circ uit. See † on pag e 27. DISABLING i WITH FUNCTION LOCK To lock the m eter in eit her the c ontinui ty/diode or ohms fun ...

  • Fluke PN 2063508 - page 18

    12 Multimeter MEAS URI NG CAPACITANCE 15 MEASURING CAPACITA NCE First, turn off p ower to the circuit, a nd dis connect and discharge the ca pacitor. 1. Insert test leads, an d move the slide-sw itch to [ E ]. (See Figure 6 .) 2. Press [ E ]. The capac itance func tion is select ed and µF is dis played . 3. Touch the prob es to th e capacit or. Wh ...

  • Fluke PN 2063508 - page 19

    12 Multimeter Users Manual 16 Figure 6. Measuring Capacitance ...

  • Fluke PN 2063508 - page 20

    12 Multimeter USING MIN MAX FUNCTIO NS 17 USING MIN MAX FUNCTION S Recording Minimum and Maximum Readings MIN MAX rec ords the highes t and lowes t measurem ents taken. MIN M AX cannot be used when the meter is measuring capacita nce. In t he MIN M AX mode, autora nging, Standby, and i are dis able d. 1. Insert the test leads , and put the meter i ...

  • Fluke PN 2063508 - page 21

    12 Multimeter Users Manual 18 Figure 7. Displaying Minimum and Maximum Reading ...

  • Fluke PN 2063508 - page 22

    12 Multimeter USING MIN MAX FUNCTIO NS 19 Recording Minimum and Maximum Reading with Elapsed Time The MIN MAX w ith elapsed-t ime mode r ecords the t ime (in hours and m inutes) between when M IN MAX was entered and the last high a nd low w as recorded . Time is kept to 99:59. OL is dis played for longer t imes . 1. To enable the MIN MAX el apsed-t ...

  • Fluke PN 2063508 - page 23

    12 Multimeter Users Manual 20 Figure 8. Maximum and Minimum Reading with Elapsed Time ...

  • Fluke PN 2063508 - page 24

    12 Multimeter USING MIN MAX FUNCTIO NS 21 Capturing Continuity Intermittents with Continuity Capture When testing c ontin uity, the m eter can cap ture intermittents as short as 250 µs, and display them as open-t o-short a nd short-to-op en trans itions . 1. Put the slide-s witch i n the conti nuity/o hms pos ition. 2. Connect th e leads to t he c ...

  • Fluke PN 2063508 - page 25

    12 Multimeter Users Manual 22 Figur e 9. Open-to-Sh o r t and Sho r t-to -Op en Tran siti ons ...

  • Fluke PN 2063508 - page 26

    12 Multimeter TURNING BEE PER OFF 23 TURNING BEEPER OFF To disable a ll beep er func tions, pr ess and ho ld dow n [ Z ] for 2 second s whil e tu r ning the meter on. MAINTENANCE W Warning To avoid el ectrical sho ck or damag e to the m eter, do not g et water in side the case. Remov e the test l eads and any input signal s bef ore opening t he cas ...

  • Fluke PN 2063508 - page 27

    12 Multimeter Users Manual 24 Service and P arts This meter s hould be s erviced on ly by a qualified s ervice tec hnic ian. To order t he servic e manual (PN 900824) and oth er parts or for servic e inform ation, in th e USA call 1-800-825-9810. Outside t he USA, c ontact the neares t Fluke serv ice c enter. Accessories When using ac ces sories, p ...

  • Fluke PN 2063508 - page 28

    12 Multimeter SPECIF ICA TION S 25 Maximum Voltage Between any Terminal and Earth Ground 600 V rms Display 3 3/ 4-digits, 4000 counts , updates 4/sec Operating Temperature -10 °C to 50 °C Storage Temperature -30 °C to 60 °C indefinitely (to -40 °C for 100 hrs) Temperature Coefficient 0.1 x (specified accuracy )/°C (<18 °C or >28 °C) R ...

  • Fluke PN 2063508 - page 29

    12 Multimeter Users Manual 26 Functi on Range Resolu tion Accur acy (50 to 4 00 Hz) 4000 mV* 1 mV ±(1.9 %+3) 4.000 V 0.001 V ±(1.9 %+3) 40.00 V 0.01 V ±(1.9 %+3) 400.0 V 0.1 V ±(1.9 %+3) 600 V 1 V ±(1.9 %+3) 4000 mV* 1 mV ±(0.9 %+2) 4.000 V 0.001 V ±(0.9 %+2) 40.00 V 0.01 V ±(0.9 %+1) 400.0 V 0.1 V ±(0.9 %+1) 600 V 1 V ±(0.9 %+1) 400.0 ? ...

  • Fluke PN 2063508 - page 30

    12 Multimeter SPECIF ICA TION S 27 Functi on Overl oad Prote ction* Input Impe danc e (Nomi nal) Comm o n Mo de Rejection Ratio (1 k Ω Unbalan ce) Norma l Mode Rejection 600 V dc >10 M Ω < 100 pF † & Lo Z = >2 k Ω <200 pF >100 dB at dc, 50 Hz or 60 Hz >50 dB at 50 Hz or 60 Hz 600 V rms >5 M Ω < 100 pF † & ...

  • Fluke PN 2063508 - page 31

    12 Multimeter Users Manual 28 ...

Fabricant Fluke Catégorie Weather Radio

Les documents que nous recevons du fabricant de l'appareilFluke PN 2063508 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Fluke
- manuels d’utilisations PN 2063508
- fiches produit Fluke
- dépliants
- ou étiquettes-énergie Fluke PN 2063508
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Fluke PN 2063508.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Fluke PN 2063508, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Fluke PN 2063508. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Fluke PN 2063508.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Fluke PN 2063508, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Fluke PN 2063508 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Fluke PN 2063508.

Le manuel d’utilisation complet Fluke, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Fluke PN 2063508 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Fluke PN 2063508, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFluke PN 2063508 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Fluke PN 2063508 - qui devraient nous aider dans les premières étapes lors de l'utilisation Fluke PN 2063508
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Fluke PN 2063508
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Fluke PN 2063508 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Fluke PN 2063508?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Fluke PN 2063508, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Fluke PN 2063508 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)