Manuel d’utilisation Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES

38 pages 2.47 mb
Télécharger

Aller à la page of 38

Summary
  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 1

    NA TURAL GAS “VICTORIAN” MODEL (V)V42ENA(1) SERIES PROP ANE/LP GAS “VICTORIAN” MODEL (V)V42EP A(1) SERIES *Aftermarket: Completion of sale, not f or purpose of resale, fr om the manufacturer . Save this manual for future reference. Save this manual for future reference. For more information, visit www.desatech.com For more information, visi ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 2

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 2 SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/ ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 3

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching. 6. Carefully super ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 4

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 4 PRODUCT FEA TURES These are a few facts that can help you understand and enjoy your direct-vent fireplace: • The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 5

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 CLEARANCES Minimum clearances to combustibles for the fireplace are as follows: Back, and sides 0"/mm Perpendicular walls 6" (152mm) Floor 0"/mm Ceiling to louver opening 42" (1067mm) Front 36" (914mm) Top 0"/mm Ven ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 6

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 6 Fixed Closed Openable Fix ed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PR OHIBITED) A = clearance abov e grade , veranda, ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 7

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 These models are tested and approved for use with DESA (direct- vent) pipe components and terminations. The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate soli ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 8

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 8 INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal T ermination • V ertical T ermination Horizontal Termination Installation IMPORTANT: Horizontal square terminations require only inner portion of wall fi ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 9

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 WARNING: Do not recess vent termination into any wall. This will cause a fire hazard. 6. Noncombustib le Exterior W all: Position the horizontal vent cap in the center of the 8 1 / 2 " round hole and attach to the exte- rior wall with four ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 10

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 10 V ertical (V) Horizontal (H) 36 3 / 4 " 17" max. Horizontal High Wind Square Termination Wall Firestop 45 ° Elbow Figure 14 - Horizontal Termination Configuration for Square or Round Termination 45 ° Elbow Wall Firestop Horizontal Rou ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 11

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 Required V ertical (V) V ertical Pipe Horizontal (H) *46 1 / 4 " min. None 30" max. 57 1 / 4 " min. 1 ft. 48" max. 69 1 / 4 " min. 2 ft. 60" max. 81 1 / 4 " min. 3 ft. 84" max. 93 1 / 4 " min. 4 ft. ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 12

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 12 V enting with Tw o 90 ° Elbows Horizontal (H 1 ) + V ertical (V) Horizontal (H 2 ) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. 20' max. 20' max. 45 ° Elbow V enting with T ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 13

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 INSTALLATION FOR VERTICAL TERMINATION Note: Vertical restrictor must be installed in all vertical installations. 1. Determine the route your vertical venting will take. If ceiling joists, roof rafters, or other framing will obstruct the ventin ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 14

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 14 VENTING INST ALLA TION INSTRUCTIONS Continued Vertical Termination Configurations Figures 21 through 24 show four different configurations for verti- cal termination. Figure 21 - Vertical Venting Configuration Using Two 90 ° Elbows with Two Hori ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 15

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 VENTING INST ALLA TION INSTRUCTIONS Continued V er tical V enting V = 40' max. Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown) HIGH ALTITUDE INSTALLATION Your DESA direct-vent ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 16

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 16 01800 Horizontal Square High Wind Termination (1) 01801 14" Snorkel Termination - Galvanized (1) 01802 36" Snorkel Termination - Galvanized (1) DESA Venting Accessories Number Description 01504 Firestop Plate (4) 01505 Adjustable Roof F ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 17

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 V a r i a b le F a n S w i t c h W h i te W h i t e B l a c k G r e e n O n 1 1 0 / 1 1 5 V . A . C . Blower Motor B la c k B l a c k B la c k O f f CAUTION: Never touch the blower wheel while in operation. 4. Be certain that all wire terminal ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 18

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 18 Figure 29 - Blower Wiring Diagram for Thermostat-Controlled Models Blower Wiring Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation af ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 19

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 FIREPLACE INST ALLA TION Continued FIREPLACE INSTALLATION Installing Gas Piping to Fireplace Location INSTALLING GAS PIPING TO FIREPLACE LOCATION Installation Items Needed Before installing fireplace, make sure you have the items listed below. ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 20

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 20 Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage firep ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 21

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 FIREPLACE INST ALLA TION Continued FIREPLACE INSTALLATION Checking Gas Connections (Cont.) Removing/Replacing Glass Door Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 33, page 20). 2. Open propane/LP su ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 22

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 22 Figure 38 - Installing Rear Brick Panel Figure 39 - Installing Left Side and Top Brick Panels Rear Brick Panel Left Side Brick Panel 10. Close glass door and lock latches on top and bottom of door and replace screen. See Removing/Replacing Glass ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 23

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 FIREPLACE INST ALLA TION Continued FIREPLACE INSTALLATION Installing Logs, Lava Rock, and Glowing Embers Figure 41- Installing Log No. 2 2 Figure 42 - Installing Log No. 3 3 2 . Rest le f t s i d e o f l o g # 2 (front log) onto top of log #1. ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 24

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 24 OPTIONAL REMOTE CONTROL INSTALLATION (Model WRC) Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operat ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 25

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 OPERA TING FIREPLACE OPERATING FIREPLACE For Your Safety Read Before Lighting Lighting Instructions To Turn Off Gas To Appliance Optional Remote Operation Figure 49 - Turning Equipment Shutoff Valve to the OFF Position TO TURN OFF GAS TO APPLI ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 26

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 26 OPERATING FIREPLACE Operating Optional Blower Accessory INSPECTING BURNERS Pilot Assembly Burner Flame Pattern OPERA TING FIREPLACE Continued OPERATING OPTIONAL BLOWER ACCESSORY Locate the blower controls by opening the lower louver panel on the ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 27

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 CLEANING AND MAINTENANCE Glass Door Pilot and Burners Logs Venting System PILOT AND BURNERS • Remove ember material before cleaning burners and replace when cleaning is complete. • Burner and controls should be cleaned with compressed air ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 28

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 28 TROUBLESHOOTING The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2 . Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM Ignitor will not spark or pilot will not lig ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 29

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a ne ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 30

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 30 ILLUSTRATED PARTS BREAKDOWN Models (V)V42ENA(1), (V)V42ENSA(1), (V)V42ENHA(1), (V)V42EPA(1), (V)V42EPSA(1), (V)V42EPHA(1) ILLUSTRA TED P ARTS BREAKDOWN MODELS (V)V42ENA(1), (V)V42ENSA(1), V)V42ENHA(1), (V)V42EPA(1), (V)V42EPSA(1), (V)V42EPHA(1) 6 ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 31

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 REFRACTORY BRICK PANELS V42ENSA(1) VV42ENSA(1) V42ENHA(1) VV42ENHA(1) V42EPSA(1) VV42EPSA(1) V42EPHA(1) VV42EPHA(1) DESCRIPTION QTY 111299-02 111299-01 111302-02 111302-01 Left Refractory Brick Panel 1 111297-02 111297-01 111300-02 111300-01 R ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 32

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 32 ILLUSTRATED PARTS BREAKDOWN Models (V)V42ENA(1), (V)V42ENSA(1), (V)V42ENHA(1), (V)V42EPA(1), (V)V42EPSA(1), (V)V42EPHA(1) ILLUSTRA TED P ARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS (V)V42ENA(1), (V)V42ENSA(1), (V)V42ENHA(1), (V)V42EPA(1), (V)V42EPS ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 33

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 33 33 KEY PART NO. NUMBER DESCRIPTION QTY. 1 108373-01 Burner Assembly Base 1 2 108330-01 Burner Pan Assembly 1 3 11165 Screw #10 x 5/8 MD TR BLK 12 4 108376-01 Tube Burner 1 5 104506-24 Pan Burner Orifice (Natural Gas) 1 104506-20 Pan Burner Orific ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 34

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 34 (V)V42ENA(1) Series (V)V42EPA(1) Series Btu 25,000/35,000 Btu/hr 23,000/33,000 Btu/hr Gas Type Natural Propane/LP Ignition Electronic Electronic Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 5.5" w.c. 11.0&qu ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 35

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 35 35 1. Where will the product be used? ❍ Living/F amily Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Gar age ❍ Bedroom ❍ Bathroom ❍ Other 2. If you bought this product yourself , did you plan to purchase this type of product ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 36

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 36 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required T APE T APE ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 37

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 37 37 ACCESSORIES Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESA’s Sales Department at 1-866-672-6040. for information. You can also write to the address listed on the back page o ...

  • Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - page 38

    111907-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 38 LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintaine ...

Fabricant Desa Catégorie Outdoor Fireplace

Les documents que nous recevons du fabricant de l'appareilDesa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Desa
- manuels d’utilisations V)V42EPA(1) SERIES, V)V42ENA(1) SERIES
- fiches produit Desa
- dépliants
- ou étiquettes-énergie Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES.

Le manuel d’utilisation complet Desa, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDesa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES - qui devraient nous aider dans les premières étapes lors de l'utilisation Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)