Manuel d’utilisation A.O. Smith NW 37-670

12 pages 0.26 mb
Télécharger

Aller à la page of 12

Summary
  • A.O. Smith NW 37-670 - page 1

    1 DURA-POWER MODELS NW 37- 670 COMMERCIAL ELECTRIC W A TER BOILERS • Inst allation • Operation • Service • Maintenance • Limited Warranty PLACE THESE INSTRUCTIONS ADJACENT T O THE BOILER AND NOTIFY OWNER T O KEEP FOR FUTURE REFERENCE.BE SURE THA T THE W ARRANTY INFORMA TION HAS BEEN FILLED IN ON COMPLETION OF INST ALLA TION. PRINTED IN U. ...

  • A.O. Smith NW 37-670 - page 2

    2 DIMENSIONAL DA T A SIZES AND DA T A 45KW THRU 720KW Model Number Inlet* & Boiler Prefix Gal.Cap. Std.KWInput D E F G** H J K S T U Outlet* Drain N W 37 45K 32 30 12 42 12 1 /2 - - 20 4 42 3 1 N W 37 60K 32 30 12 42 12 1 /2 - - 20 4 42 3 1 N W 37 75K 32 30 12 42 12 1 /2 - - 20 4 42 2 1 N W 37 90K 32 30 12 42 12 1 /2 - - 20 4 42 3 1 N W 37 105K ...

  • A.O. Smith NW 37-670 - page 3

    3 SIZES AND DA T A 780KW THRU 3300KW Model Number Inlet* & Boiler Prefix Gal.Cap. Std.KWInput D E F G** H J K S T Outlet* Drain N W 220 780K 60 50 25 71 21 2 25 1/2 30 5 1/ 2 5 1 1/ 2 N W 220 840K 60 50 25 71 21 2 25 1/2 30 5 1/ 2 5 1 1/ 2 N W 220 900K 60 50 25 71 21 2 25 1/2 30 5 1/ 2 5 1 1/ 2 N W 220 960K 60 50 25 71 21 2 25 1/2 30 5 1/ 2 5 1 ...

  • A.O. Smith NW 37-670 - page 4

    4 ELECTRICAL/RECOVER Y DA T A MODEL AND RA TING PLA TE W A TER BOILER SPECIFICA TIONS Model Number Gal. Std. KW BTU Output Gal./Hr . Number of Number of Standard Number Amperage 3 Phase Prefix Cap. Input 100°F Rise Elements Steps and KW of Steps 208v 240V 480V 575V N W 37 45 K 153,585 180 3 1 1@45 128 108 55 45 N W 37 60 K 204,720 240 4 1 1@60 171 ...

  • A.O. Smith NW 37-670 - page 5

    5 APPROV ALS These designs comply with requirements of Underwriters Laboratories and bear the U.L. label on the cabinet. All models are built to the standards of Section lV of the American Society of Mechanical Engineers. Boiler and Pressure Code, inspected and identified by this symbol. The ASME plate is located on the tank above the cleanout open ...

  • A.O. Smith NW 37-670 - page 6

    6 IMPORT ANT IT IS RECOMMENDED THA T A QUALIFIED SER VICE TECHNICIAN PERFORM THE INITIAL FIRING OF THE BOILER. A T THIS TIME THE USER SHOULD NOT HESIT A TE TO ASK THE TECHNICIAN ANY QUESTIONS WHICH THEY MA Y HA VE IN REGARD TO THE OPERA TION AND MAINTENANCE OF THE BOILER. BEFORE FILLING THE SYSTEM FOR OPERA TION the hot water system should be inter ...

  • A.O. Smith NW 37-670 - page 7

    7 Calculating Amperage/Overcurrent Protection The boiler is factory wired for connection to three wire single-phase or three and four wire three-phase branch circuits. In addition, a ground conductor may be required. A diagram of the wiring is furnished with the boiler for the electrician’s use. An amperage table is on page 4 of this manual. The ...

  • A.O. Smith NW 37-670 - page 8

    8 ELECTRICAL CONFIGURA TION T ABLE Boiler T ype V olt age Between Control Elements Nameplate o f Boiler T erminal Circuit Quantity Element Markings Service Lugs V ol t age Per Operating V oltage Phase (1 Phase) Contractor V oltage 1 120 1 208 208 3 Delta (With 12 0 1 2 08 Neutral) 1 120 1 2 40 240 3 Delta 120 1 240 480 3 Wy e* 1 20 1 or 2 277 480 3 ...

  • A.O. Smith NW 37-670 - page 9

    9 WIRING DIAGRAM 480V THREE-PHASE (WYE) SYSTEM CLEANING The hot water system should be internally cleaned and flushed to remove contaminants which may have accumulated during installation. System cleaning provides chemical stability necessary for component life and system performance. Failure to clean the system may cause: 1. Poor heating due to fo ...

  • A.O. Smith NW 37-670 - page 10

    10 4. Close the vent as water starts to flow from the opening. Place the make-up water valve in the desired position. The boiler is now ready for ST ART UP and TEMPERA TURE REGULA TION if being placed in operation for the first time. ST ART UP The following checks should be made by the installer when the boiler is placed into operation for the firs ...

  • A.O. Smith NW 37-670 - page 11

    11 • Use a twisting, pulling action to remove elements scaled beyond the size of the tank opening. • Brush loose scale from elements. • Silicates, sulfates and aluminates must be removed by scraping or other mechanical means. Lime scale dissolvents will not remove these types of scale which are occasionally encountered. 5. Lime scale removal: ...

  • A.O. Smith NW 37-670 - page 12

    12 NW -37 THRU NW-670 ELECTRIC HOT W A TER BOILER LIMITED W ARRANTY A.O. Smith Corporation, the warrantor , extends the following LIMITED WARRANTY to the owner of this boiler . 1. THE T ANK If the tank in this boiler shall prove upon examination by the warrantor to have leaked due to natural corrosion from water therein, during the FIRST year after ...

Fabricant A.O. Smith Catégorie Boiler

Les documents que nous recevons du fabricant de l'appareilA.O. Smith NW 37-670 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques A.O. Smith
- manuels d’utilisations NW 37-670
- fiches produit A.O. Smith
- dépliants
- ou étiquettes-énergie A.O. Smith NW 37-670
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation A.O. Smith NW 37-670.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation A.O. Smith NW 37-670, manuels d’entretien, brefs manuels ou manuels de l’utilisateur A.O. Smith NW 37-670. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit A.O. Smith NW 37-670.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil A.O. Smith NW 37-670, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser A.O. Smith NW 37-670 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs A.O. Smith NW 37-670.

Le manuel d’utilisation complet A.O. Smith, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel A.O. Smith NW 37-670 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières A.O. Smith NW 37-670, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lA.O. Smith NW 37-670 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil A.O. Smith NW 37-670 - qui devraient nous aider dans les premières étapes lors de l'utilisation A.O. Smith NW 37-670
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de A.O. Smith NW 37-670
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service A.O. Smith NW 37-670 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de A.O. Smith NW 37-670?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec A.O. Smith NW 37-670, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec A.O. Smith NW 37-670 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)