  • APC CTSLLP/G - page 1

    990-5517 04/2003 BroadBand CTSLLP/G Series Pole and Ground Mount Stan dby Power Supply Enclosures User Manual ...

  • APC CTSLLP/G - page 2

    ...

  • APC CTSLLP/G - page 3

    1 Chapter 1 General Information The CTSLLP/G Standby Power Supp ly Series Enclosures pr ovide a power sour ce for broadband cable operations. Safety This Safety Guide contains important instructio ns that s hould be foll owed duri ng installa tion and maintenance of the APC equipment an d batteries. It is intended for APC customers who setup, insta ...

  • APC CTSLLP/G - page 4

    2 Specifications Environmental Specifications Operating Temperature -40º F to 140º F (-4 0º C to 60º C) Humidity 5% to 95% n oncondensing w ithin enclosure Physical Specifi cations Characteristic Specificatio n Height x Widt h x Depth CTSLLGULH110 S1 CTSLLPULH100S1 CTSLLGECH2 20S1 20” x 22” x 7.5” (5 1cm x 56 cm x 19 cm) 14” x 22” x 7 ...

  • APC CTSLLP/G - page 5

    3 Chapter 2 Installation Only trained service personnel should install and maintain the power supp ly. Prior to installation, utility line vo ltage must be ro uted to the enclosure. Local, state, federal and/or National Electr ic Code (NEC) regulations regarding l ocation, perm its and electrical wiring must be adhered to . Do not operate the power ...

  • APC CTSLLP/G - page 6

    4 CTSLL Enclosure Installation CTSLLG Enclosure Installation 1. Remove the lid from the battery vault. 2. Position the CTSLLG on the edge of the vault lid. 3. Install two 5/16” (.8 cm) x 1” (2.5 cm) flat head screws through the lid into th e holes in the back of the CTSLLG. 4. Install f our 5/16” (.8 cm ) x 3/4” (2 cm) flat head screws thro ...

  • APC CTSLLP/G - page 7

    5 CTSLLP Enclosure Installation When wall mounting, use screws that are appropriate for the weigh t of the unit and the mounting surface material. Refer to Specifications in this manual. Mounting Bracket is permanently attached to the enclosure. 5/8” (1.5 cm) Pole Bolt and Square Washer Top Hole .75” (2 cm) Bottom Hole .75” (2 cm) 11.5” (29 ...

  • APC CTSLLP/G - page 8

    6 Controls and Indicators CTSLLP/G Bottom View Index Control/Indicator Definition 1 Ground wire l ug Provides conne ction of chas sis to earth ground 2 Utility power input indicator lam p (not present on all m odels) Yellow indicator illuminates wh en line voltage is present 3 Normal indicator lamp Green indicator illuminates when the unit is opera ...

  • APC CTSLLP/G - page 9

    7 Wiring Install an approved 20 A high-magnetic utility circuit breaker. Ensure the utility circuit breaker is OFF. • Unlock and open the front/top panel on the CTSLLP/G. Refer to the diagram below for wiri ng details. • Connect the black and wh ite wires from the incoming utility line. • Route the po wer feed coa x to the bottom of the encl ...

  • APC CTSLLP/G - page 10

    8 Install the Battery Vault Refer to User Manual 990-1220 packaged with the battery vau lt for installation instruction s. Connect the Batteries in the Battery Vault Refer to User Manual 990-1220 packaged with the Battery Vault for ba ttery connection details. Install the temperature sensor on top of the batter ies as shown in the 990-1220 User Man ...

  • APC CTSLLP/G - page 11

    9 Chapter 3 Troubleshooting and Maintenance Troubleshooting Power Supply Failure Problem Possible Cause Solution No input voltage detected at connector J1, pins 1 and 2. Replace the wiring harness Input volta ge present at co nnector J1, pins 1 and 2. Disconnect power from the supply No input voltage at the black and white wires input lines. Replac ...

  • APC CTSLLP/G - page 12

    10 Routine Maintenance Proc edures • Visual Inspection • Check external surfaces, connectors, indicator s a nd wiring/cable assemblies for signs of dirt, wear, and dam age. • Cleaning • Brush dust f rom controls a nd receptacles usi ng a small paintbr ush. • Wipe surfaces with clean, dry cheesecloth. • Clean exterior surface with clean ...

  • APC CTSLLP/G - page 13

    11 • Complete Perform ance Verification. Refer to Initial Startup in the CTFLM/CTSLM User Manual 990-5501. • Replace/close the enclosure door(s ). • Indicator Lamp Replacement Gently pry the lens off the indicator lamp using th e tip of a screwdriver. NOTE: Place a h and over the le ns as it is loose ned to ensure that the lens is not lost du ...

  • APC CTSLLP/G - page 14

    12 Chapter 4 Service, Con tact and Warranty Information Service APC makes every effort to ensure parts and equipment arrive in working condition. Occasionally, it may be necessary to return parts or equi pment that are not i n working condition. If the unit requires service d o not return it to the dealer. Follow these step s: 1. Contact APC Custom ...

  • APC CTSLLP/G - page 15

    13 Limited Warranty American Power Conversion (APC) warrants its products to be fr ee from defects in mater ials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under wa rr anty you mus ...

Fabricant APC Catégorie Power Supply

Les documents que nous recevons du fabricant de l'appareilAPC CTSLLP/G peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques APC
- manuels d’utilisations CTSLLP/G
- fiches produit APC
- dépliants
- ou étiquettes-énergie APC CTSLLP/G
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation APC CTSLLP/G.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation APC CTSLLP/G, manuels d’entretien, brefs manuels ou manuels de l’utilisateur APC CTSLLP/G. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit APC CTSLLP/G.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil APC CTSLLP/G, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser APC CTSLLP/G par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs APC CTSLLP/G.

Le manuel d’utilisation complet APC, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel APC CTSLLP/G - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières APC CTSLLP/G, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAPC CTSLLP/G qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil APC CTSLLP/G - qui devraient nous aider dans les premières étapes lors de l'utilisation APC CTSLLP/G
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de APC CTSLLP/G
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service APC CTSLLP/G dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de APC CTSLLP/G?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec APC CTSLLP/G, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec APC CTSLLP/G il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)