Eaton 5P 1150VA AU - page 1
5P 650 AU 5P 650i R 5P 850 AU 5P 850i R 5P 1150 AU 5P 1150i R 5P 1550 AU 5P 1550i R User's guide ...
-
Eaton 5P 1150VA AU - page 2
...
-
Eaton 5P 1150VA AU - page 3
ENGLISH Copyright © 2012 EATON All rights reserved. Service and support: Call your local service representative 620-00082-01-au (en) Tower models 5P 650 AU 5P 850 AU 5P 1150 AU 5P 1550 AU 1U Rack models 5P 650i R 5P 850i R 5P 1150i R 5P 1550i R Installation and user manual ...
-
Eaton 5P 1150VA AU - page 4
Page 2 620-00082-0 1-au (en) Cer tication Standards Special S ymbols The following are examples of symbols used on the UPS or accessories to aler t you to impor tant information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. Important instructions that must always be followed. Do not discard the ...
-
Eaton 5P 1150VA AU - page 5
Page 3 620-00082-0 1-au (en) ENGLISH Contents 1 . Intr oduction ....................................................................................... 4 1 .1 Environmental protection ................................................................................................... 4 2. Pr esentation ............................................... ...
-
Eaton 5P 1150VA AU - page 6
Page 4 620-00082-0 1-au (en) 1. Introduction Thank you for selecting an EA TON product to protect your electrical equipment. The 5P range has been designed with the utmost care. W e recommend that you tak e the time to read this manual to take full advantage of the many features of your UPS (Uninterruptible P ower System). Before installing 5P , pl ...
-
Eaton 5P 1150VA AU - page 7
Page 5 620-00082-0 1-au (en) ENGLISH 2. Presentation 2.1 Standar d installations T ower models D H W Description Weights (lb/ kg ) Dimensions (inch/ mm ) D x W x H 5P 650AU 16.60 / 7.52 13.6 x 9.2 x 5.9 / 345 x 233 x 150 5P 850AU 21.90 / 9.93 13.6 x 9.2 x 5.9 / 345 x 233 x 150 5P 1150AU 24.10 / 10.91 13.6 x 9.2 x 5.9 / 345 x 233 x 150 5P 1550AU 35. ...
-
Eaton 5P 1150VA AU - page 8
Page 6 620-00082-0 1-au (en) 2. Presentation 2.2 T o wer r ear panels 5P 650 A U / 5P 850 AU / 5P 1 150 A U 3 2 1 4 6a 6b 5 7 8 5P 1550 AU 3 2 1 4 6a 6b 5 7 8 (1) USB communication port (2) RS232 communication port (3) Slot for optional communication card (4) Connector for ROO (remote ON/OFF) or RPO (Remote Power Off) control (5) Outlets for connec ...
-
Eaton 5P 1150VA AU - page 9
Page 7 620-00082-0 1-au (en) ENGLISH 2. Presentation 2.3 Rack r ear panels 5P 650i R / 5P 850i R 2 1 4 8 7 3 6a 6b 5 5P 1 150i R 6a 2 1 4 8 7 3 6b 5 5P 1550i R 6a 2 1 4 8 7 3 6b 5 (1) USB communication port (2) RS232 communication port (3) Slot for optional communication card (4) Connector for ROO (remote ON/OFF) or RPO (Remote Power Off) control ( ...
-
Eaton 5P 1150VA AU - page 10
Page 8 620-00082-0 1-au (en) 2. Presentation 2.4 Contr ol panel TheUPShasave-buttongraphicalLCD.ItprovidesusefulinformationabouttheUPSitself ,loadstatus, events, measurements and settings. T ower models Power On Indicator (green) On battery Indicator (yel - low) Alarm Indicator (red) Normal mode ...
-
Eaton 5P 1150VA AU - page 11
Page 9 620-00082-0 1-au (en) ENGLISH 2. Presentation 2.5 LCD descr iption Operation status Load/equipment status Normal mode 100 % 10min 100% 720W 800V A Efficiency: ~98% Battery status Efficiency and load group information As default, or after 5 minutes of inactivity, the LCD displays the screen saver . The backlight LCD automatically dims after ...
-
Eaton 5P 1150VA AU - page 12
Page 10 620-00082-0 1-au (en) 2.6 Displa y functions Press the Enter ( ) button to activate the menu options. Use the two middle buttons ( and ) to scroll through the menu structure. Press the Enter ( ) button to select an option. Press the button to cancel or return to the previous menu. Menu map for Displa y Functions. Main menu Submenu Display i ...
-
Eaton 5P 1150VA AU - page 13
Page 11 620-00082-0 1-au (en) ENGLISH 2. Presentation Description Available settings Default settings In/Out settings Load segments - Auto shutdown delay [Disable] [0s] [1 s] [2 s]…[65354 s] During a power outage, authorises to keep some equipment running while turning off other equipment. This feature allows to save battery power. Group 1: Disab ...
-
Eaton 5P 1150VA AU - page 14
Page 12 620-00082-0 1-au (en) 3. Installation 3.1 Unpacking and cont ents check Tower models 1 2 3 5 6 Rack models 2 3 5 6 4 7 1 8 (1) 5P UPS (2) Quick start and safety instructions (3) User manual and IPSS (Intelligent Power Software Suite) CDROM (4) 2 connection cables for the protected equipment (5) RS232 communication cable (6) USB communicatio ...
-
Eaton 5P 1150VA AU - page 15
Page 13 620-00082-0 1-au (en) ENGLISH 3. Installation 3.2 Installation of t ow er models 3.3 Wall installation of rack models 1 1 2 2 ...
-
Eaton 5P 1150VA AU - page 16
Page 14 620-00082-0 1-au (en) 3.5 Installation of r ack models (850i R / 1 150i R / 1550i R) Follow steps 1 to 4 for module mounting on the rails. 3. Installation The rails and necessary hardw are are supplied by EA TON. 1 1 2 2 3 3 4 4 3.4 Installation of r ack models (650i R only) Follow steps 1 to 3 for rack mounting. 2 3 2 3 1 ...
-
Eaton 5P 1150VA AU - page 17
Page 15 620-00082-0 1-au (en) ENGLISH 3. Installation 3.5 Communication por ts Connection of RS232 or USB communication por t The RS232 and USB communication ports cannot operate simultaneously. 2 1 5 6 1. Connect the RS232 (5) or USB (6) communication cable to the serial or USB port on the computer equipment. 2. Connect the other end of the commun ...
-
Eaton 5P 1150VA AU - page 18
Page 16 620-00082-0 1-au (en) 4. Operation 4.1 Star t-up and Nor mal operation T o start the UPS: 1. V erify that the UPS power cord is plugged in. 2. The UPS front panel display illuminates and shows EA T ON logo. 3. V erify that the UPS status screen shows . 4. Press the button on the UPS front panel for at least 2 seconds. The UPS front panel di ...
-
Eaton 5P 1150VA AU - page 19
Page 17 620-00082-0 1-au (en) ENGLISH 4. Operation Low -batt ery war ning • The and indicator illuminates solid. • The audio alarm beeps every three seconds. The remaining battery power is low. Shut down all applications on the connected equipment because automatic UPS shutdown is imminent. End of bat tery backup time • LCD displays ...
-
Eaton 5P 1150VA AU - page 20
Page 18 620-00082-0 1-au (en) 5. Maintenance 5.1 T r oubleshooting Operation status Possible cause Action Batteries disconnected The UPS does not recognise the internal batteries If the condition persists, contact your service representative The batteries are disconnected Verify that all batteries are properly connected. If the condition persists, ...
-
Eaton 5P 1150VA AU - page 21
Page 19 620-00082-0 1-au (en) ENGLISH 5. Maintenance 5.2 Bat t ery -module r eplacement Saf ety recommendations The battery can cause electrocution and high short-circuit cur rents. The following safety precautions are required before servicing the battery components: • remove w atches, rings, bracelets and all other metal objects from the han ...
-
Eaton 5P 1150VA AU - page 22
Page 20 620-00082-0 1-au (en) Bat tery tr ay r emov al on rack models This operation must be performed when the UPS is switched OFF . A B A - Remove the middle part. B - Remove the left-hand side of the front panel by pushing the button and then by sliding the part. C C - Disconnect the battery block by separating the two connectors (never pull on ...
-
Eaton 5P 1150VA AU - page 23
Page 21 620-00082-0 1-au (en) ENGLISH 6. Appendices 6.1 T echnical specications Tower 5P 650 AU 5P 850 AU 5P 1150 AU 5P 1550 AU Rack 5P 650i R 5P 850i R 5P 1150i R 5P 1550i R Output Power @ 230 V 650 VA 420 W 850 VA 600 W 1150 VA 770 W 1550 VA 1100 W Output Power @ 208 V 585 VA 378 W 765 VA 540 W 1035 VA 693 W 1395 VA 990 W Output Power @ 200 V ...
-
Eaton 5P 1150VA AU - page 24
Page 22 620-00082-0 1-au (en) 6. Appendices Backup time Time during which the load can be supplied by the UPS operating on battery power. Battery test Internal UPS test to check battery status. Cold start The devices connected to the UPS can be started even if AC input power is not available. The UPS operates on battery power alone. Deep discharge ...
-
Eaton 5P 1150VA AU - page 25
...
-
Eaton 5P 1150VA AU - page 26
www.eaton.com/Powerquality EATON 5P 620-00082-01-au ...
Avez-vous une question à propos de Eaton 5P 1150VA AU?
Utiliser le formulaire ci-dessous
Si vous n’avez pas résolu votre problème avec Eaton 5P 1150VA AU, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Eaton 5P 1150VA AU il est probable qu’il a envie de partager la façon de le résoudre.