Manuel d’utilisation Jet J100ECA

24 pages 0.33 mb
Télécharger

Aller à la page of 24

Summary
  • Jet J100ECA - page 1

    PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL J100ECA 100,000 BTU/Hr 100 SIDE PV 002 J150ECA 150,000 BTU/Hr 150 SIDE PV 004 IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. ...

  • Jet J100ECA - page 2

    2 Safety Information ......................................................................... 3 Product Identification .................................................................... 4 Unpacking ...................................................................................... 5 Assembly .................................................. ...

  • Jet J100ECA - page 3

    3 SAFETY INFORMA TION ! W ARNINGS IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. • Use only kerosene or No. 1 fuel oil to avoid ris ...

  • Jet J100ECA - page 4

    4 PRODUCT IDENTIFICA TION Lower Shell Hot Air Outlet Figure 1 - 100,000 BTU/Hr Model Fuel Cap Side Cover Power Cord Fuel Tank Fan Guard Upper Shell Fuel Cap Fan Guard Figure 2 - 150,000 BTU/Hr Model Hot Air Outlet Lower Shell Power Cord Air Filter End Cover Upper Shell Fuel Tank ...

  • Jet J100ECA - page 5

    5 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping car ...

  • Jet J100ECA - page 6

    6 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fi ne mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. Th ...

  • Jet J100ECA - page 7

    7 VENTILA TION OPERA TION ! W ARNING Follow the minimum fresh, outside air ventilation require- ments. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater. Provide a fresh air opening of at least three square feet (2800 square cm) for each ...

  • Jet J100ECA - page 8

    8 ST ORAGE 1. Drain fuel tank. Note: Locate drain plug on underside of fuel tank. Remove drain plug to drain all fuel. Be sure all fuel is removed. 2. Replace drain plug. 3. Add one gallon (4 liters) of clean kerosene to fuel tank. 4. Attach fuel cap. 5. Move heater forwards and backwards to stir fuel. 6. Remove drain plug and drain fuel tank. Be s ...

  • Jet J100ECA - page 9

    9 TROUBLE- SHOOTING ! W ARNING Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Heater burns, but creates puffs of smoke. Heater will not burn steady. Heater burns with odor. Heater smokes continuously. OBSERVED FAULT POSSIBLE CAUSE REMEDY A) Water in fuel B) Wrong fuel Wrong pump pressure ...

  • Jet J100ECA - page 10

    10 150 SHELL REMOVAL EA/EB Euro PFA/P 054 SER VICE PROCEDURES ! W ARNING Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2. Lift upper shell off ...

  • Jet J100ECA - page 11

    11 Fuel Filter (100,000 BTU/Hr Model) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel fi lter neck. 4. Carefully pry bushing, lower fuel line, and fuel fi lter out of fuel tank. 5. Wash fuel fi lter with clean fuel and replace in tank. 6. Attach upper fuel line to fuel fi lter neck ...

  • Jet J100ECA - page 12

    12 Spark Plug 1. Remove upper shell (see page 10). 2. Remove fan (see page 17). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Clean and regap spark plug electrodes as follows: .055" (1.4 mm) = 100,000 BTU/Hr model .075" (1.9 mm) = 150,000 BTU/Hr model 6. Install spar ...

  • Jet J100ECA - page 13

    13 125 PRESSURE ADJUSTMENT Plu g Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover. 4. Replace air output and lint fi lters. 5. Wash or replace air intake fi lter (see Preventative Maintenance Schedule, page 8). 6. Replace ? ...

  • Jet J100ECA - page 14

    14 Nozzle (100,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 17). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using 5/16" nut-driver and remove burner head from comb ...

  • Jet J100ECA - page 15

    15 Nozzle (150,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 17). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Loosen fl are nut using 3/4" open-end wrench. Push fuel tube down. 6. Remove air line hose from burner head. 7. Remove three s ...

  • Jet J100ECA - page 16

    16 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover and air fi lters. 4. Remove pump plate screws using 5/16" nut- driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades. 7. Check for debris in pump. If debr ...

  • Jet J100ECA - page 17

    17 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" Allen wrench to loosen setscrew which holds fan to motor shaft. 3. Slip fan off motor shaft. 4. Clean fan using a soft cloth moistened with kero ...

  • Jet J100ECA - page 18

    18 WIRING DIAGRAM ACCESSOR Y Output Rating (BTU/Hr) 100,000 150,000 Fuel Use Only Kerosene or No. 1 Fuel Oil Fuel Tank Capacity (U.S. Gal./Liters) 9/34 13.5/51 Fuel Consumption (Gal. Per Hr./Liters Per Hr.) .74/2.8 1.10/4.16 Electric Requirements 120 volt/60 hertz 120 volt/60 hertz Amperage (Normal Run) 4.5 4.5 Hot Air Output (CFM/CMM) 480/13.6 648 ...

  • Jet J100ECA - page 19

    19 ASSEMBLY, EURO PFA/PV 018A 1 2 3 4 5 6 7 WHEELS AND HANDLES FOR 100,000 AND 150,000 BTU/Hr MODELS KEY PART PART 100,000 150,000 NO. NUMBER DESCRIPTION QTY. QTY. 1 HA2203 Handles 2 — HA2205 Handles — 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 8 3 M12342-3 Wheel Support Frame 1 — M12831-3 Wheel Support Frame — 1 4 NTC-3C Nut Torque, #10-2 ...

  • Jet J100ECA - page 20

    20 PFA/P 010 MOTOR & PUMP 100 EAI/EBI ILLUSTRA TED P ARTS BREAKDOWN 100,000 BTU/Hr Model 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13-8 13-9 13-10 13-11 13-12 13-13 13-15 13-16 13-17 13-18 13-14 Motor and Pump Assembly BURNER HEAD 100 EAI/EBI PFA/P 022 8-2 8-6 8-5 8-4 8-3 8-1 Burner Head Assembly 8-7 1 2 3 8 9 10 11 12 13 14 15 16 17 19 20 25 28 27 29 ...

  • Jet J100ECA - page 21

    21 P ARTS LIST 100,000 BTU/Hr Model This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-30 Upper Shell 1 2 M15823-27 Screw, #10-16 x 1 ...

  • Jet J100ECA - page 22

    22 BURNER HEAD 150 EAI/EBI PFA/P 028 ILLUSTRA TED P ARTS BREAKDOWN 150,000 BTU/Hr Model 22-1 22-2 22-3 22-4 22-5 22-6 22-7 22-8 22-9 22-10 22-11 22-12 22-13 22-14 22-15 22-16 22-17 22-18 8-7 8-6 8-5 8-4 8-3 8-2 8-1 Burner Head Assembly PFA/P 013 MOTOR & PUMP 150 EAI/EBI Motor and Pump Assembly 8-8 1 2 3 8 9 4 5 7 10 14 15 18 19 20 22 16 17 23 2 ...

  • Jet J100ECA - page 23

    23 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 150,000 BTU/Hr Model KEY PART PART NO. NUMBER DESCRIPTION QTY. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-50 U ...

  • Jet J100ECA - page 24

    24 Printed in U.S.A. 099661-01 Rev. B 8/91 W ARRANTY AND REP AIR SERVICE Contact the Spares and Service Division of: Ludlow Road, Knighton, Powys LD7 1LP Telephone: Knighton (0547) 528534 Telex: 35323 ...

Fabricant Jet Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilJet J100ECA peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Jet
- manuels d’utilisations J100ECA
- fiches produit Jet
- dépliants
- ou étiquettes-énergie Jet J100ECA
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Jet J100ECA.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Jet J100ECA, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Jet J100ECA. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Jet J100ECA.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Jet J100ECA, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Jet J100ECA par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Jet J100ECA.

Le manuel d’utilisation complet Jet, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Jet J100ECA - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Jet J100ECA, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lJet J100ECA qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Jet J100ECA - qui devraient nous aider dans les premières étapes lors de l'utilisation Jet J100ECA
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Jet J100ECA
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Jet J100ECA dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Jet J100ECA?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Jet J100ECA, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Jet J100ECA il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)