    ES30-ISAP Pan and T ilt System C312M-A (12/02) ® OPERA TION/PROGRAMMING ...

  • Pelco es30-isap - page 2

    2 C312M-A (12/02) CONTENTS Section Page DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 MODELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Pelco es30-isap - page 3

    C312M-A (12/02) 3 LIST OF ILLUSTRA TIONS Figure Page 1 POD 100 Attachment to the T ilt T able . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Pelco es30-isap - page 4

    4 C312M-A (12/02) DESCRIPTION The ES30-ISAP is an innovative addition to the Esprit ® Series Positioning System family designed specifically for the POD 100 Thermal Imager (not supplied). The system includes the Esprit receiver , pan and tilt, power supply , and an exclusively designed connector and mount for the thermal imager . MODELS ES30-ISAP- ...

  • Pelco es30-isap - page 5

    C312M-A (12/02) 5 INST ALLA TION POD 100 1. Refer to Figure 1 and attach the POD 100 to the tilt table of the Esprit with the 1/4-20 x .50-inch screw (supplied). POD100 TIL T T ABLE ESPRIT P AN AND TIL T SYSTEM Figure 1. POD 100 Attachment to the Tilt Table 2. Refer to Figure 2 and attach the harness cable to the system. NOTE: The tilt table, power ...

  • Pelco es30-isap - page 6

    6 C312M-A (12/02) P AN AND TIL T 1. Remove the transformer module from the base of the system by loosening the four Phillips screws and lifting the module. 01475 BASE MOUNTING SCREWS MOUNT LOOSEN PHILLIPS SCREWS TRANSFORMER MODULE BASE 2. Attach the base of the system to an Esprit mount (EWM or EPP) with the three flathead 10-32 x 1/2-inch screws a ...

  • Pelco es30-isap - page 7

    C312M-A (12/02) 7 3. Route the wires and cables from the transformer module through the center of the Esprit mount. Reinstall the transformer module into the base. The transformer module can be positioned in the mount base in only one orientation. 120/230 VOL T AGE SELECTOR SWITCH 4. ES30-ISAP-5 Model Only – Set the 120/230 voltage selector switc ...

  • Pelco es30-isap - page 8

    8 C312M-A (12/02) 8. Plug the male Esprit system connector , located on the bottom of the pan and tilt, into the female Esprit system connector loc ated on the transformer module. Align the pan and tilt part number with the alignment label on the base, and then attach the pan and tilt to the base with three 1/4-20 nuts and washers (supplied). PA R ...

  • Pelco es30-isap - page 9

    C312M-A (12/02) 9 TXB SERIES TRANSLA TOR BOARD INST ALLA TION (OPTIONAL) Pelco’ s TXB Series allows controllers from other companies to communicate with the Esprit system. To install a TXB Series board, remove the left cover of the pan and tilt. Once the cover is removed, refer to the manual suppli ed with the translator board to complete the ins ...

  • Pelco es30-isap - page 10

    10 C312M-A (12/02) To reinstall the pan and tilt cover , do the following: 1. Properly position the cover and slide it into place. The sides of the cover must fit under the front and back rain guards of the pan and tilt, and the top of the cover must seat against the lip of the top gasket. 2. Apply pressure and push the top of the cover down to ali ...

  • Pelco es30-isap - page 11

    C312M-A (12/02) 11 OPERA TION POWER-UP DISPLA Y When the Esprit system is powered up or reset, the selected protocol, revision number , and other information is displayed on th e monitor . The information remains on the monitor until the system is moved. P AN AND TIL T OPERA TION Operation How to Control Pan and T ilt Move joystick left/right and u ...

  • Pelco es30-isap - page 12

    12 C312M-A (12/02) OPERA TING NOTES ENVIRONMENT AL RANGE The operating temperature ranges from a minimum of -40 ° F (-40 ° C) to a maximum of 122 ° F (50 ° C) for sustained system operation or 140 ° F (60 ° C) absolute maximum. PA N AND TIL T FUNCTIONS Controller Pan T ilt T ype (Capability , 360 ° Continuous (V iewing Range, +33 ° to -83 ? ...

  • Pelco es30-isap - page 13

    C312M-A (12/02) 13 RANDOM, FRAME, AND AUTO SCANNING Select preset 97 (30) to start random scanning. Select preset 98 (31) to activate frame scanning (three seconds of scanning followed by a three-second pause). Select preset 99 (32) to start auto (continuous) scanning. Scan limit stops are controlled by software. Refer to the Limit Stops section to ...

  • Pelco es30-isap - page 14

    14 C312M-A (12/02) QUICK ST ART GUIDE – SYSTEM SETUP PROGRAMMING GUIDE – ES30-ISAP P AN AND AND TIL T SYSTEM 1. Access main menu (preset 95). 2. Make main menu selections. Joystick: Move up or down to position cursor or to toggle between selections. Iris Open: Enter . Iris Close: Cancel. MAIN MENU <Camera>* <Line Sync> <Power Up ...

  • Pelco es30-isap - page 15

    C312M-A (12/02) 15 HOW TO ACCESS THE MAIN MENU (PRESET 95) Y ou can call up the main menu on your monitor by programming (setting or creating) preset 95 (preset 28 if in AD32-preset mode). Programming preset 95 for Pelco’ s controllers varies according to the type of controller you are using. Instructions for progra mming preset 95 are given belo ...

  • Pelco es30-isap - page 16

    16 C312M-A (12/02) CAMERA For information on camera operation, refer to the manual supplied with the POD 100 thermal imager or contact Industrial Security Alliance Partners, Inc. at (619) 232-7041. Main Menu <Camera> <Line Sync> <Power Up Mode> <Limit Stop> <Other> EXIT Camera Menu Polarity Auto Cal Man Cal Reset Camer ...

  • Pelco es30-isap - page 17

    C312M-A (12/02) 17 LIMIT STOPS TURNING LIMIT STOPS ON OR OFF To change the limit stop mode: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Position the cursor (>) beside Limit Stops. 5. Press the Iris Open button. The cursor moves t ...

  • Pelco es30-isap - page 18

    18 C312M-A (12/02) Clear Manual Stops To clear the manual limit stops: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Move the cursor to Clear Man Limits, and press the Iris Open button. The cursor will flash to an asterisk (*) briefly ...

  • Pelco es30-isap - page 19

    C312M-A (12/02) 19 LINE SYNCHRONIZA TION If cameras are out of phase with each other , they may produce what appears to be vertical roll when switching between cameras. There are two settings for line synchronization: ON – Adjust the synchronization of the power line voltage so that it is in phase with other cameras. OFF – The system synchroniz ...

  • Pelco es30-isap - page 20

    20 C312M-A (12/02) PA TTERN LENGTH The ESPRIT can do the following: One full pattern – 1.5, 3, or 6 minutes long or T wo half patterns – .75, 1.5, or 3 minutes long This pattern can consist of any standard pan and tilt command. Presets, flip, and turbo are not allowed in a pattern. Zone scan can be enabled while running a pattern. To set the pa ...

  • Pelco es30-isap - page 21

    C312M-A (12/02) 21 POWER-UP MODE This feature lets the system resume a desired condition following power -up. The menu includes the following choices. • Default – On power -up, the system goes through a configuration cycle and stops at zero reference, showing “Configuration Done,” address, and mode settings on the screen. • Park – The s ...

  • Pelco es30-isap - page 22

    22 C312M-A (12/02) PROPORTIONAL P AN Proportional pan does not function with this version of Esprit. Main Menu <Camera> <Line Sync> <Power Up Mode> <Limit Stop> <Other> EXIT Other Menu Proportional pan On Park time minutes 0 Scan speed deg/s 25 Pattern length 1.5 min Spd Profile 90 MPH wind <Zone Blank> Exit ➞ ...

  • Pelco es30-isap - page 23

    C312M-A (12/02) 23 SCAN SPEED The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan modes: auto, random, and frame scan. To change the scan speed: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Other . 3. Press the Iris Open button to enter the menu entitled Other . 4. Position ...

  • Pelco es30-isap - page 24

    24 C312M-A (12/02) ZONES Basic rules for setting zones: 1. Refer to the documentation for your control system to program zones. 2. Establish zones using the controller , prior to programming ZONE BLANK with the Esprit on-screen menu. 3. T o accurately set zone areas, zoom wide to the maximum field of view . 4. Set zones moving the joystick left to ...

  • Pelco es30-isap - page 25

    C312M-A (12/02) 25 PRODUCT SUPPORT ES30-ISAP PAN AND TIL T SYSTEM CONT ACT : Pelco 3500 Pelco Way Clovis, CA 93612 USA T el: 800/289-9100 (USA & Canada) 1-559/292-1981 (International) www .pelco.com POD 100 THERMAL IMAGER (CAMERA) CONT ACT : Industrial Security Alliance Partners, Inc. 1495 Pacifica Highway , Suite 350 San Diego, CA 92101 T el: ...

  • Pelco es30-isap - page 26

    26 C312M-A (12/02) APPENDIX NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switch settings have no effect on Coaxitron control signals. Table A. Switch Settings for SW1 Baud Rate Switch Setting SW1-1 SW1-2 SW1-3 2400 OFF OFF OFF* 4800 ON OFF OFF* 9600 ...

  • Pelco es30-isap - page 27

    C312M-A (12/02) 27 Table B. Switch Settings for SW2 Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 1– OFF OFF OFF OFF OFF OFF OFF OFF 21 O N OFF OFF OFF OFF OFF OFF OFF 32 OFF ON OFF OFF OFF OFF OFF OFF 43 O N ON OFF OFF OFF OFF OFF OFF 54 OFF OFF ON OFF OFF OFF OFF OFF 65 O N OFF O ...

  • Pelco es30-isap - page 28

    28 C312M-A (12/02) Table B. Switch Settings for SW2 (Continued) (Continued on next page) Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 – 112 OFF OFF OFF OFF ON ON ON OFF – 113 ON OFF OFF OFF ON ON ON OFF – 114 OFF ON OFF OFF ON ON ON OFF – 115 ON ON OFF OFF ON ON ON OFF – 1 ...

  • Pelco es30-isap - page 29

    C312M-A (12/02) 29 Table B. Switch Settings for SW2 (Continued) Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 – 232 OFF OFF OFF ON OFF ON ON ON – 233 ON OFF OFF ON OFF ON ON ON – 234 OFF ON OFF ON OFF ON ON ON – 235 ON ON OFF ON OFF ON ON ON – 236 OFF OFF ON ON OFF ON ON ON ...

  • Pelco es30-isap - page 30

    30 C312M-A (12/02) SPECIFICA TIONS (PAN AND TIL T SYSTEM ONL Y) ELECTRICAL Input V oltage: 24, 120, or 230 V AC, 50/60 Hz; switch selectable for 120/230 V AC inputs Output V oltage for POD100: 12 VDC ( ± 10%), with POD100 installed Power Consumption: Maximum 50 V A per system Electrical Connections: T wo power source connections made at mount loca ...

  • Pelco es30-isap - page 31

    C312M-A (12/02) 31 ® Pelco, the Pelco logo, Spectra, Genex, Legacy, Coaxitron, Esprit, and Camclosure are register ed trademarks of Pelco. © Copyright 2002, Pelco. All rights reserved. REVISION HISTORY Manual # Date Comments C312M 11/02 Original version. C312M-A 12/02 Added FCC Class B information. W ARRANTY AND RETURN INFORMA TION W ARRANTY Pelc ...

  • Pelco es30-isap - page 32

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada ® ...

Fabricant Pelco Catégorie TV Mount

Les documents que nous recevons du fabricant de l'appareilPelco es30-isap peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Pelco
- manuels d’utilisations es30-isap
- fiches produit Pelco
- dépliants
- ou étiquettes-énergie Pelco es30-isap
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Pelco es30-isap.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Pelco es30-isap, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Pelco es30-isap. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Pelco es30-isap.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Pelco es30-isap, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Pelco es30-isap par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Pelco es30-isap.

Le manuel d’utilisation complet Pelco, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Pelco es30-isap - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Pelco es30-isap, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lPelco es30-isap qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Pelco es30-isap - qui devraient nous aider dans les premières étapes lors de l'utilisation Pelco es30-isap
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Pelco es30-isap
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Pelco es30-isap dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Pelco es30-isap?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Pelco es30-isap, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Pelco es30-isap il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)