    262675-UIM-A-0806 MODULAR NON-V ARIABLE SPEED AIR HANDLERS MODELS: MA INSTALLATION MANUAL ISO 9001 Certified Quality Management System SECTION I: GENERAL This modular air handler provides the flexibility for installation in any upflow , downflow , or horizontal application. These versatile models may be used for cooling or heat pump operati on with ...

  • York MA - page 2

    262675-UIM-A-0806 2 Unitary Products Group 1. Install this air handler only in a location and position as specified in SECTION III of these instructions. 2. Always install the air handler to operate within the air handler ’s intended maximum outlet air t emperature. Only connect the air handler to a duct system which has an external static pressu ...

  • York MA - page 3

    262675-UIM-A-0806 Unitary Products Group 3 DOWNFL OW AND HORIZONT AL CONVERSION These air handler units are supplied r eady to be installed in a upflow , downflow and left or right hand horizontal position. If the unit is to be installed with an evaporator coil, refer to Figure 1 for unit positioning information. AIR HANDLER AND COIL UPFL OW AND HO ...

  • York MA - page 4

    262675-UIM-A-0806 4 Unitary Products Group DUCT CONNECT ORS Air supply and return may be handled in one of several ways best suited to the installation. See Figure 3 for dimensions for duct inlet and outlet connections. The vast majority o f problems encountered with combination heating and cooling systems can be linked to improperly designed or in ...

  • York MA - page 5

    262675-UIM-A-0806 Unitary Products Group 5 HORIZONT AL SUSPENSION For suspension of these units in hor izontal applications, it is recom- mended to use angle steel support brackets with threaded rods, sup - porting the units from the bottom, at the locations shown in Figure 4. SECTION IV : ELECTRIC HEA TER INST ALLA TION If the air handler requires ...

  • York MA - page 6

    262675-UIM-A-0806 6 Unitary Products Group NOTE: All wiring must comply with lo cal and national electrical code requirements. Read and heed all unit caution labels. NOTE: It is possible to vary the amount of electric hea t turned on during the defrost cycle of a heat pump. St andard wiring will only bring on the first stage of electric heat during ...

  • York MA - page 7

    262675-UIM-A-0806 Unitary Products Group 7 External Relay Outputs The control includes thre e outputs to drive external relays having 24 V AC coils. The outputs have a maximum rating of 1.0 Amp pilot duty at 24 V AC. HUM OUT The HUM OUT output can be used to drive an external relay or solenoid (24 V AC coil) to control a humidifier . The output is ...

  • York MA - page 8

    262675-UIM-A-0806 8 Unitary Products Group SECTION VIII: BLO WER SPEED CONNECTIONS All air handlers contain 3-speed blower motors which are prewired to the control board. Adjust blower motor speed to provide air flow within the minimum and maximum limits approved for evaporator coil, electric heat and outdoor unit. S peed tap adjustments are made a ...

  • York MA - page 9

    262675-UIM-A-0806 Unitary Products Group 9 SECTION IX: UNIT DA T A TA B L E 7 : Physical and Electrical Data Models: MA 08B21 12B21 12B41 14D21 Blower - Diameter x Width 10 x 9 10 x 9 10 x 9 10 x 10 Motor HP 1/4 HP 3/4 HP 3/4 HP 1/2 HP Nominal RPM 1075 1075 1075 1075 V oltage 208 / 230 208 / 230 460 208 / 230 Amps Full Load 1.5 3.5 2.3 2.4 Filter 1 ...

  • York MA - page 10

    262675-UIM-A-0806 10 Unitary Products Group * May be 0 (no breaker) or 1 (with breaker). TA B L E 1 1 : Electrical Data - 1 Ø - 208/23 0-1-60 Models MA Heat Kit - Single Phase Max. Stat i c Min. Spe ed Ta p To ta l H e a t 1 KW Staging KW MBH W1 Only W2 Only W1 + W2 208V 240V 208V 240V 208V 240V 208V 240V 208V 240V 08BN21 4HK*6500206 0.5 Lo 1.9 2. ...

  • York MA - page 11

    262675-UIM-A-0806 Unitary Products Group 11 * May be 0 (no breaker) or 1 (with breaker). T ABLE 13: Electrical D a t a - (For Single Source Power Supply) - Copper W ire 1 Ø - 208 /230-1-60 Models MA Heat Kit - Single Phase* Heater Amps 240V Field W iring Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C W ire Size - A WG 208V 240V 208V 240V ...

  • York MA - page 12

    262675-UIM-A-0806 12 Unitary Products Group 2. Heaters are 3 Phase. T ABLE 15: Elect rica l Data - (For Multi-Source Power Supply) - Copper W ire 3 Ø - 2 08/230-3-60 Models MA Heater Model Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C Wir e Size - A WG Circuit Circuit Circuit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/240 2 08/240 208/240 ...

  • York MA - page 13

    262675-UIM-A-0806 Unitary Products Group 13 All MA series air handler unit s are UL Listed up to 0.50" w .c. external static pressure, including air filte r , wet coil, and la rgest KW size heater . T ABLE 19: Air Flow Data - 60 Hz Models (23 0 & 460 Volt) Models MA Models MC Blower Motor Speed 230 / 460 V olt - 60 Hz CFM 1 @ External St a ...

  • York MA - page 14

    262675-UIM-A-0806 14 Unitary Products Group All MA series air handler unit s are UL Listed up to 0.50" w .c. external static pressure, including air filte r, wet coil, and la rgest KW size heater . T ABLE 20: Air Flow Data - 60 Hz Models (208 V olt) Models MA Models MC Blower Motor Speed 208 V olt - 60 Hz CFM 1 @ External St atic Pressure - IW ...

  • York MA - page 15

    262675-UIM-A-0806 Unitary Products Group 15 1. “Y” T erminal on Air Handler Control Board must be connected for full CFM and applications req uirin g 60 second blower of f del ay for SEER enhancement. 2. Optional humidity switch - contact s open on humidity rise. 3. Remove HUM ST A T Jumper on AH Control Board 4. MODE Jumper on AH control board ...

  • York MA - page 16

    Subject to change without notice. Printed in U.S.A. 262675-UIM-A-0806 Copyright © by York International Corp. 2006. Al l rights reserved. Supersedes: 170341-UIM-C-0806 Unitary 5005 Norman Product Y ork OK Group Drive 73069 NOTES ...

Fabricant York Catégorie Air Cleaner

Les documents que nous recevons du fabricant de l'appareilYork MA peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques York
- manuels d’utilisations MA
- fiches produit York
- dépliants
- ou étiquettes-énergie York MA
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation York MA.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation York MA, manuels d’entretien, brefs manuels ou manuels de l’utilisateur York MA. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit York MA.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil York MA, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser York MA par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs York MA.

Le manuel d’utilisation complet York, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel York MA - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières York MA, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lYork MA qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil York MA - qui devraient nous aider dans les premières étapes lors de l'utilisation York MA
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de York MA
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service York MA dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de York MA?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec York MA, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec York MA il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)