Manuel d’utilisation Lowrance electronic EP-60R

48 pages 2.22 mb
Télécharger

Aller à la page of 48

Summary
  • Lowrance electronic EP-60R - page 1

    1 Pub. 988-0154-432 EP-60R Fuel Flow Electronic Sensor Installation, Configuration and Calibration Instructions This document shows how to install an EP-60R Fuel Flow sensor and how to connect it to a NMEA 2000 ® network. It also provides instructions on how to configure and calibrate your fuel flow sensor with Lowrance digital gauges (L MF-200 &a ...

  • Lowrance electronic EP-60R - page 2

    2 Some sonar or GPS display units may require a software upgrade to display NMEA 2000 data correctly. For free software upgrades or additional information on the LowranceNet NMEA 2000 ® network system, visit our web si te, www.lowrance.com. The EP-60R consists of a red cabl e connector and the sensor module. The sensor module contains a turbine to ...

  • Lowrance electronic EP-60R - page 3

    3 LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot extension cable, T connector and two 120-ohm terminators. For complete instructions on se tting up a new NMEA 2000 network or expanding an existing one, see the other document packed with your EP-60R Fuel Flow, " Setup and Installation of NMEA 2000 Networks, General Information ...

  • Lowrance electronic EP-60R - page 4

    4 Cut the fuel hose where you intend to install the EP-60R sensor. Slide a clamp over the hose coming from the tank, then push the hose onto the bottom (inlet) hose barb. Seat the hose flush against the sens or housing, then tighten the hose clamp. Attach the hose leading to the engine on the top (outlet) barb in the same way. Push the fuel line on ...

  • Lowrance electronic EP-60R - page 5

    5 Connecting to a NMEA 2000 Network A NMEA 2000 network is a communications link between two or more devices that transfer NMEA 2000 in formation. LowranceNET is the NMEA 2000 networking system develo ped by Lowrance Electronics. A NMEA 2000 network functions like the phone wiring in a house. If, for example, you pick up a phone in the living room ...

  • Lowrance electronic EP-60R - page 6

    6 NMEA 2000 network node located at the end of a NMEA 2000 backbone. NOTE: If you have a double T Connector on your network that is not attached to a device, you must cap the unused connector with a NMEA 2000 cap. This will protect the pin connectors from corrosion. The NMEA 2000 cap looks like a terminator, but has "Cap" stamped into the ...

  • Lowrance electronic EP-60R - page 7

    7 In this example, a new device is added to the N ME A 2000 bus by installing a T conn ector between a T connector and a terminator at the end of the backbone (network bus). Additional Network Information For more information on creating or expanding a network refer to the NMEA 2000 network setup booklet, par t num ber 988-0154-173, which came pack ...

  • Lowrance electronic EP-60R - page 8

    8 Notes ...

  • Lowrance electronic EP-60R - page 9

    9 LMF-200: EP-60R Configuration & Calibration This section covers how to use th e EP-60R Fuel Flow with a LMF-200 Multi-function gauge. NOTE: You will notice the LMF-200 does not have an Exit key. Menus will time out after a preset amount of time (3, 5, 10 or 15 seconds). The default setting is 5 seconds. Re fer to your LMF-200 instruction manu ...

  • Lowrance electronic EP-60R - page 10

    10 3. Select the tank you want to set up and press MENU , which will open the Tank Size window. 4. Use the UP and DOWN keys to input the number of gallons the tank will hold and press MENU . Repeat steps 3 and 4 for each additional tank. After all tanks have been set up, you will be directed to the m ain display. Boat Setup Reset If you want to acc ...

  • Lowrance electronic EP-60R - page 11

    11 3. Select U N C FG FF and press MENU . The following message will appear: Hit Menu to Cfg Flow Sns. Press MENU and the Configuration options menu will appear. NOTE: If your unit is set to a sing le-engine configuration, the Configuration Options menu will not appear when you are configuring a fuel flow. The fuel flow will automatically be config ...

  • Lowrance electronic EP-60R - page 12

    12 If all fuel flows configured (Configuration name unav ailable): 1. Press MENU , use the UP and DOWN k e y s t o s e l e c t S YSTEM S ETUP and press MENU . 2. Highlight B. D EVICES and press MENU . The Bus Devices list will appear. 3. Select the Port FFlow and press MENU . 4. Highlight U NSET E NGINE and press MENU . The following message will a ...

  • Lowrance electronic EP-60R - page 13

    13 5. You will be taken back to the Bus Devices list, where the fuel flow you selected (formerly Port FFlow) w ill be listed as Stbd FFlow. If the newly configured fuel flow is not shown, refresh the Bus Devices list. Reset The Reset command in the Fuel Flow level menu will clear the sensor’s configuration and calibration settings. NOTE: After us ...

  • Lowrance electronic EP-60R - page 14

    14 To customize Fuel Manage r page: 1. With the Fuel Manager page displayed on the main display, press MENU , select C USTOMIZE and press MENU . 2. Highlight USD (Fuel Used) and press MENU . If your unit is configured for more than one tank, the Select Tank menu will appear. (If your engine-tank configuration is set for on e tank, you will be direc ...

  • Lowrance electronic EP-60R - page 15

    15 9. The Recalibration (The Recal?) menu will appear with two options: Yes and No. Select Y ES and press MENU . NOTE: If you do not have the fuel rema ining source set to Eng/FFlow, the recalibration message will not appear. 10. The Filled Quantity window will appear. Use the UP and DOWN keys to input the amount of fuel you added to the tank and p ...

  • Lowrance electronic EP-60R - page 16

    16 add fuel to a tank without completely filling it up, you must use the Partial Fill command. This will ensure the fuel information in the EP- 60R stays consistent with the amount of fuel actually in the tank. To use Partial Fill: 1. Press MENU , use the UP and DOWN k e y s t o s e l e c t S YSTEM S ETUP and press MENU . Highlight F UEL MNGR and p ...

  • Lowrance electronic EP-60R - page 17

    17 To Reset Trip Fuel (Rst trip f) 1. Press MENU , use the UP and DOWN keys to select S YSTEM S ETUP and press MENU . Highlight F UEL MNGR and press MENU . 2. Select R ST TRIP F (Reset Trip F uel) and press MENU . The Select Engine menu will appear with up to four opti ons. Select the desired engine or All Engines and press MENU . (If you are using ...

  • Lowrance electronic EP-60R - page 18

    18 6. Use the UP and DOWN keys to input the desired percentage of tank capacity and press MENU . Let the menus time out to return to the main display. NOTE: To turn off a fuel warning, repeat Steps 1-4, then select O FF from the Level Percentage window mentioned in Step 5. Press MENU . Repeat these steps for each warning you want to turn off. Let t ...

  • Lowrance electronic EP-60R - page 19

    19 Autoscroll feature if you want the pages to automatically scroll across the screen. Refer to your LMF -200 manual for more information about Autoscroll. A dding a page: 1. Press MENU , use the UP and DOWN keys to select P AGE S and press MENU , which will open the Pages menu with the following options: Add Page, Rem Page, Autos croll and Set Pop ...

  • Lowrance electronic EP-60R - page 20

    20 menu will appear, allowing you to display data from a single engine or show data from all engines. (If you select F UEL R ANGE (RNG) or if your unit is configured for one engine, you will be taken back to the main display.) 5. Select the desired engine or, to display data from all engines, highlight Vessel and press MENU . You will be taken back ...

  • Lowrance electronic EP-60R - page 21

    21 LMF-400: EP-60R Configuration & Calibration This section covers how to use th e EP-60R Fuel Flow with a LMF-400 Multi-function gauge. LMF-400 Multi-function Digital gauge. Boat Setup If this is the first time you have turned on your LMF-400, you will have to complete Boat Setup before you w ill be able to configure or calibrate your fuel flo ...

  • Lowrance electronic EP-60R - page 22

    22 Boat Setup Reset If you want to access the Setup scr een (Boat Setup) after an engine- tank configuration has been chosen you will have to reset the configuration to default settings. To reset engine-tank config uration: 1. Press MENU , highlight S YSTEM S ETUP and press ENTER . 2. Choose E NG /T ANK C FG and press ENTER twice. The following mes ...

  • Lowrance electronic EP-60R - page 23

    23 1. Press MENU , use the UP and DOWN k e y s t o s e l e c t S YSTEM S ETUP and press ENTER . 2. Highlight B US D EVICES and press ENTER . The Bus Devices list will appear. Bus Devices highlighted in the System Setup menu (left). Searching Bus Devices window (center) wi th Bus Devices list (right). 3. Select U N C FG F F LOW and press ENTER . The ...

  • Lowrance electronic EP-60R - page 24

    24 flow to free up its configuration name. If all three fuel flows are configured, which means there is no configuration name available, follow the first set of instructions. If the desired configuration name is available, follow the second set of instructions . Change Engine (activ e only with multiple-engine setting) The steps below show how to s ...

  • Lowrance electronic EP-60R - page 25

    25 EP-60R Fuel Flow Calibration The factory calibration settings for the EP-60R Fuel Flow should be within 3 percent, so calibration will not be necessary in most cases. NOTE : The Fuel Remaining Source must be set to fuel flow for the unit to correctly display fuel level info rmation. Follow the instructions below to ensure fuel flow (Eng/FFlow) h ...

  • Lowrance electronic EP-60R - page 26

    26 2. Press MENU , use the UP and DOWN k e y s t o s e l e c t S YSTEM S ETUP and press ENTER . 3. Highlight F UEL S ETUP and press ENTER . 4. Select R EFILL T ANK and press ENTER . If your unit is configured for more than one tank, the Select Tank menu will open. 5. Select the tank you refilled and press ENTER . A Recalibration window (ReCalibrate ...

  • Lowrance electronic EP-60R - page 27

    27 2. Highlight B US D EVICES and press ENTER . Highlight the fuel flow you want to reset and press ENTER . 3. Select R ESET C AL from the fuel flow menu and press ENTER . The following message will appear: Press Enter to reset the Calibration . 4. Press ENTER to set calibration back to de fault settings. To recalibrate the fuel flow, follow the fu ...

  • Lowrance electronic EP-60R - page 28

    28 NOTE: When using the Partial Fill command, you will only be able to input into the gauge, an amount of fuel less or equal to the fuel used figure. The unit will not allow you to enter a fuel amount greater than the fuel used figure. 4. Use the UP and DOWN keys to input the amount of fuel added to the tank and press ENTER . You will be taken back ...

  • Lowrance electronic EP-60R - page 29

    29 To reset seasonal fuel: 1. Press MENU , select S YSTEM S ETUP and press ENTER . 2. Highlight F UEL S ETUP and press ENTER . 3. Select R ESET S EA SONA L and press ENTER . The Select Engine menu will appear with up to four options. (If you have one engine, the reset seasonal fuel message (Step 4) will appear.) 4. Select the desired engine or All ...

  • Lowrance electronic EP-60R - page 30

    30 To set an Engine Warning (A larm): 1. Press MENU , use the UP and DOWN keys to highlight S YSTEM S ETUP , and press ENTER . 2. Highlight E NGINE W A RNINGS and press ENTER . The Engine Warnings menu will appear with up to five options, including Off and All Engines. The default setting is All En gines. (If you have a single-engine configuration, ...

  • Lowrance electronic EP-60R - page 31

    31 To customize Single Digital page : 1. After the Single Digital page has been added to the page screen rotation, use the ENTER and EXIT keys to display it on the main screen. 2. Press MENU , use the UP and DOWN keys to select C USTOMIZE and press ENTER . The data menu will appear. 3. Highlight Fuel Flow, Fuel Range, F uel Used, Tr ip Fuel Used or ...

  • Lowrance electronic EP-60R - page 32

    32 data from a single engine or from all engines on the vessel. (If you select F UEL R ANGE or if your unit is configured for one engine, you will be taken back to the Position menu.) 5. Select the desired engine or, to display data from all engines, highlight Vessel and press ENTER . You will be taken back to the Position menu. To display data in ...

  • Lowrance electronic EP-60R - page 33

    33 Display Unit: EP-60R Configuration & Calibration All NMEA 2000 capable Lowrance sonar and sonar/GPS combo display units can be used to configure and calibrate your EP-60R Fuel Flow sensor on a NMEA 2000 network. The LMS-525cDF is one of many Lowrance display units that may be used to configure an EP-60R Fuel Flow sensor. NOTE: Your unit may ...

  • Lowrance electronic EP-60R - page 34

    34 Bus Setup highlighted on the NMEA 2000 menu (left). Bus Setup selected on Networking menu (right). The Engine-Tank Configuration and Tank Select menus as well as the Tank Size dialog box are located on the bottom half of the Bus Configuration menu. The Set Config uration button — positioned next to the engine-tank configuration menu — allows ...

  • Lowrance electronic EP-60R - page 35

    35 Setting Engine-Tank Configuration: 1. Press MENU twice, highlight NMEA 2000 or N ETWORKING and press ENTER . 2. The NMEA 2000 menu will appear with five options: Bus Setup, Fuel Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization. Choose B US S ETUP and press ENTER . 3. Select E NGINE & T ANK C ONFIG and press ENTER ...

  • Lowrance electronic EP-60R - page 36

    36 menu. To configure or calibrate most devices, you will select it on the NMEA 2000 Devices list and press ENTER . This will open its Device Configuration menu. Bus Configuration menu with five items displayed on the NMEA 2000 Devices list. Engine-Tank Configuration and Tank Select menus are at the bottom of the screen. Device Configuration Menu W ...

  • Lowrance electronic EP-60R - page 37

    37 EP-60R Fuel Flow Configuration When configuring your fuel flow, you will open its Device Configuration menu where you can access the Location and Advanced Options menu. You can also change your fu el flow's device name . Device Name You can change how your fuel flow will be displayed on your unit's NMEA 2000 Devices list by inputting a ...

  • Lowrance electronic EP-60R - page 38

    38 5. Highlight the device and press ENTER . The Device Configuration menu will open. The device name will be reset to its default setting. Press EXIT repeatedly to return to the main display. Location The Location menu allows you to se lect a configuration name that matches the location of the engine connected to your fuel flow sensor. To change f ...

  • Lowrance electronic EP-60R - page 39

    39 Fuel Management highlighted on Networking menu (left). Fuel Management menu (right). Fuel Management Menu The Fuel Management menu gives you access to the following options: Tank Location, Fuel Added, Add Fu el, Fill Tank, Engine Select, Reset Calibration, Reset Trip and Reset Seasonal. The menu is divided into two parts: Tank Operations and Eng ...

  • Lowrance electronic EP-60R - page 40

    40 If you filled up the tank: A. Press the F ILL T AN K button and press ENTER . The following message will appear: Are you sure you wish to Fill Tank? Press ENTER . Another message will appear: Do you wish to re-calibrate the device? Highlight N O and press ENTER . If you did not fill up the tank: B. Highlight F UEL A DDED and press ENTER to acces ...

  • Lowrance electronic EP-60R - page 41

    41 4. Highlight F ILL T AN K and press ENTER . The following confirmation message will appear: Are you sure you wish to Fill Tank? NOTE : You must use the unit’s Fill Tank command when filling your fuel tank to keep the fuel flow updated with correct information on the amount of fuel in the tank. 5. Select Y ES and press ENTER . The following con ...

  • Lowrance electronic EP-60R - page 42

    42 To Reset Calibration: Choosing the Reset Calibration command will switch fuel flow calibration settings back to factory defaults. 1. Press MENU twice, select NMEA 2000 or N ETWORKING and press ENTER . 2. Highlight F UEL M AN AG EM E N T and press ENTER . 3. Highlight to E NGI NE S ELECT and press ENTER . Select the desired engine and press ENTER ...

  • Lowrance electronic EP-60R - page 43

    43 Displaying data from fuel flow The Overlay Data function will be used to show EP-60R Fuel Flow data on your unit's main display. To add ov erlay data from the EP-60R: 1. Press MENU , highlight O VERLAY D ATA and press ENTER . 2. Select (P RESS ENT TO ADD …) and press ENTER . 3. Highlight NMEA 2000 and press ENTER . A list of devices on th ...

  • Lowrance electronic EP-60R - page 44

    44 Alarm Status Tab The Alarm Status tab is the second tab at the top of the NMEA 2000 Alarms page. When an alarm has been set for a device, the alarm and its current status will be shown on the Alarm Status window. To view Alarm Status: 1. Press MENU twice, select NMEA 2000 or N ETWORKING and press ENTER . 2. Select NMEA 2000 A LA RMS and press EN ...

  • Lowrance electronic EP-60R - page 45

    45 Notes ...

  • Lowrance electronic EP-60R - page 46

    46 Notes ...

  • Lowrance electronic EP-60R - page 47

    47 LOWRANCE ELECTRONICS FULL ONE-YEAR WARRANTY "We," "our," or "us" refers to LOWRAN CE ELECTRONICS, INC., the manufacturer of this product. "You" or "your" refers to the first person wh o purchases this p roduct as a consumer item for personal, family or household use. We warrant this product again ...

  • Lowrance electronic EP-60R - page 48

    48 How to Obtain Service… …in the USA: Contact the Factory Customer Se rvice Department. Call toll-free: For Lowrance: 800-324-1356. For Eagle: 800-324-1354 8 a.m. to 5 p.m. Central Standard Time, M-F Lowrance Electronics and Eagle Electronics ma y find it necessary to change or end their shipping policies, regulations and special offers at any ...

Fabricant Lowrance electronic Catégorie Stud Sensor

Les documents que nous recevons du fabricant de l'appareilLowrance electronic EP-60R peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lowrance electronic
- manuels d’utilisations EP-60R
- fiches produit Lowrance electronic
- dépliants
- ou étiquettes-énergie Lowrance electronic EP-60R
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lowrance electronic EP-60R.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lowrance electronic EP-60R, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lowrance electronic EP-60R. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lowrance electronic EP-60R.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Lowrance electronic EP-60R, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lowrance electronic EP-60R par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lowrance electronic EP-60R.

Le manuel d’utilisation complet Lowrance electronic, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lowrance electronic EP-60R - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lowrance electronic EP-60R, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLowrance electronic EP-60R qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lowrance electronic EP-60R - qui devraient nous aider dans les premières étapes lors de l'utilisation Lowrance electronic EP-60R
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lowrance electronic EP-60R
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lowrance electronic EP-60R dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lowrance electronic EP-60R?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lowrance electronic EP-60R, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lowrance electronic EP-60R il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)