Manuel d’utilisation Lincoln Electric IDEALARC IM402-B

21 pages 1.89 mb
Télécharger

Aller à la page of 21

Summary
  • Lincoln Electric IDEALARC IM402-B - page 1

    IDEALARC ® A C/DC 250 OPERA TOR’S MANUAL For use with machines having Code Number 9491 thru 11104. IM402-B August, 2007 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT ...

  • Lincoln Electric IDEALARC IM402-B - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric IDEALARC IM402-B - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4. b. Use suitable clothing made from durable flame-resistant material to protect your ski ...

  • Lincoln Electric IDEALARC IM402-B - page 4

    iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 . b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations. 8.c. Ground the equipment in accordance with the U.S. Natio ...

  • Lincoln Electric IDEALARC IM402-B - page 5

    iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A LʼArc 1. Protegez-vous contre la secousse électrique: a. Les circuits à ...

  • Lincoln Electric IDEALARC IM402-B - page 6

    – 6 – v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick refe ...

  • Lincoln Electric IDEALARC IM402-B - page 7

    – 7 – T ABLE OF CONTENTS Page GENERAL DESCRIPTION ..................................................................................................8 RECOMMENDED PROCESSES & EQUIPMENT ...............................................................8 AC and DC Constant Current Welding .......................................................... ...

  • Lincoln Electric IDEALARC IM402-B - page 8

    – 8 – GENERAL DESCRIPTION The Idealarc ® 250 is a single phase constant current arc welding power source available in an AC/DC model only. Designed for stick welding, it may also be used for TIG welding when used with the K799 Hi- Freq unit. RECOMMENDED PROCESSES AND EQUIPMENT AC and DC Constant Current Welding TIG Welding The K799 can be used ...

  • Lincoln Electric IDEALARC IM402-B - page 9

    – 9 – TECHNICAL SPECIFICA TIONS: IDEALARC AC/DC 250 Model AC/DC 250 AC/DC 250 Type K1053 K1054 AC Input Frequency 60 50 Output Rating NEMA CLASS II (60) IEC 974 AC DC AC DC Amperes 300 250 250 250 Volts 32 30 30 30 Duty Cycle 20 30 30 30 Current Range 35-300 40-250 35-250 40-250 Max. O.C.V. 72 70 72 70 Input Power Standard Voltages 208/230/460 ...

  • Lincoln Electric IDEALARC IM402-B - page 10

    – 10 – INST ALLA TION Safety Precautions • Connect the Idealarc 250 grounding terminal located under the reconnect panel (marked ) to a good electrical ground per the U.S. National Electrical Code and any applicable local codes. • Turn the power switch on the Idealarc 250 “OFF” before connecting or disconnecting output cables or other e ...

  • Lincoln Electric IDEALARC IM402-B - page 11

    – 11 – STACKING A. Make sure the first or bottom unit is setting on a level, well supported surface. B. The units must be stacked with their front flush, making sure the two holes in the base rails of the unit being stacked on top are over the two holes located on the top front corners of the unit being stacked on. Fasten the units together wit ...

  • Lincoln Electric IDEALARC IM402-B - page 12

    OPERA TION Safety Precautions Be sure the Idealarc 250 is properly installed, and that all accessories are properly hooked up before attempting operation. DUTY CYCLE This machine is rated at a 30% duty cycle at 250 amps or 50% duty cycle at 200 amp output. Duty cycle is based on a 10 minute period. Therefore, the welder can be loaded at 200 amperes ...

  • Lincoln Electric IDEALARC IM402-B - page 13

    MAINTENANCE Safety Precautions General Maintenance 1 . The fan motor has sealed ball bearings which requires no service. 2. In dusty locations dirt may clog the air channels causing the welder to run hot. Under these conditions carefully blow out the welder at regular intervals. 3 . Keep the electrode and work cable connection tight. 4. Every twelv ...

  • Lincoln Electric IDEALARC IM402-B - page 14

    – 14 – TROUBLE A. Welder will not weld. B. Welder welds, but soon stops welding (DC only). CAUSE 1. Line switch not turned “On”. Supply line fuse blown. 2. Power circuit dead. 3. Broken power lead. 4. Wrong voltage. 5. Electrode or work lead loose or broken. 6. Open transformer circuit. 7. Polarity switch not centered. 1. Proper ventilation ...

  • Lincoln Electric IDEALARC IM402-B - page 15

    – 15 – TROUBLE C. Variable or sluggish welding. D. Welder wonʼt shut off. E. Polarity switch wonʼt turn. CAUSE 1. Poor work or electrode terminal connection. 2. Current too low. 3. Low line voltage. 4. Welding leads too small. 5. Old and badly frayed welding cables. 1. Line switch has failed mechanically. 1. Contacts rough and pitted from imp ...

  • Lincoln Electric IDEALARC IM402-B - page 16

    – 16 – NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.. H1 L1 L2 TO GROU ...

  • Lincoln Electric IDEALARC IM402-B - page 17

    – 17 – NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.. H1 L1 L2 TO GROU ...

  • Lincoln Electric IDEALARC IM402-B - page 18

    NOTES ...

  • Lincoln Electric IDEALARC IM402-B - page 19

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA E ...

  • Lincoln Electric IDEALARC IM402-B - page 20

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes ...

  • Lincoln Electric IDEALARC IM402-B - page 21

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabricant Lincoln Electric Catégorie Welder

Les documents que nous recevons du fabricant de l'appareilLincoln Electric IDEALARC IM402-B peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lincoln Electric
- manuels d’utilisations IDEALARC IM402-B
- fiches produit Lincoln Electric
- dépliants
- ou étiquettes-énergie Lincoln Electric IDEALARC IM402-B
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lincoln Electric IDEALARC IM402-B.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lincoln Electric IDEALARC IM402-B, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lincoln Electric IDEALARC IM402-B. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lincoln Electric IDEALARC IM402-B.

Manuel d’utilisation complet de l’appareil Lincoln Electric IDEALARC IM402-B, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lincoln Electric IDEALARC IM402-B par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lincoln Electric IDEALARC IM402-B.

Le manuel d’utilisation complet Lincoln Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lincoln Electric IDEALARC IM402-B - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lincoln Electric IDEALARC IM402-B, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLincoln Electric IDEALARC IM402-B qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lincoln Electric IDEALARC IM402-B - qui devraient nous aider dans les premières étapes lors de l'utilisation Lincoln Electric IDEALARC IM402-B
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lincoln Electric IDEALARC IM402-B
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lincoln Electric IDEALARC IM402-B dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lincoln Electric IDEALARC IM402-B?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lincoln Electric IDEALARC IM402-B, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lincoln Electric IDEALARC IM402-B il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)