Manuel d’utilisation Omega DP3001

24 pages 1.26 mb
Télécharger

Aller à la page of 24

Summary
  • Omega DP3001 - page 1

    http://www.omega.com e-mail: info@omega.com ™ ® U ser’s Guide DP3001 DIGITAL PANEL VOLTMETER ...

  • Omega DP3001 - page 2

    ...

  • Omega DP3001 - page 3

    i TABLE OF CONTENTS SAFETY CONSIDERATIONS ......................................................................................... iii 1.0 GENERAL INFORMATION ........................................................................................ 1 2.0 SPECIFICATIONS ................................................................................ ...

  • Omega DP3001 - page 4

    ii LIST OF FIGURES: Figure 3.1 DIN Case Dimensions .................................................................................. 4 Figure 3.2 Exploded View .............................................................................................. 5 Figure 4.1 Side View of Transformer ........................................................ ...

  • Omega DP3001 - page 5

    iii SAFETY CONSIDERATIONS This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility). Unpacking & Inspection Unpack the instrument and inspect for obvious shipping d ...

  • Omega DP3001 - page 6

    ...

  • Omega DP3001 - page 7

    1 1.0 GENERAL INFORM AT I ON This voltmeter is a 4 1/2 digit panel meter f or applications which require a compact, quality DC v oltmeter . This model uses dual-slope conversion. Additionally , it provides automatic z eroing before each reading and does so with a minimum of par ts f or increased reliability . The voltmeter has a resolution of 1 par ...

  • Omega DP3001 - page 8

    2 2.4 A CCURA CY A T 25°C Maximum error ±0.01% of reading ±2 counts Span tempco ±0.01% of reading/°C Step response 1 second W ar m-up to rated accuracy 10 minutes 2.5 DIGIT AL INPUTS P ositive true referenced to DIG GND 2.6 ANALOG-T O-DIGIT AL CONVERSION T echnique Dual-slope, av erage-v alue Input integration period 100 milliseconds Read rate ...

  • Omega DP3001 - page 9

    3 2.10 MECHANICAL Bezel 96 x 48 x 5.1 mm (3.78 x 1.89 x 0.20 in) Depth behind bezel 104 mm (4.09 in) (with connector) P anel cutout 92 x 45 mm (3.62 x 1.77 in) W eight 400 g (14 oz) Case material 94V -0 UL-rated polycarbonate D1 connector option PCB edge connector with a double ro w of (non-CE) 18-pins, 3.96 mm (0.156 in) spacing between pin s D4 c ...

  • Omega DP3001 - page 10

    4 Figure 3.2 Exploded View 3.2 P ANEL MOUNTING 1. Remo ve main board connector J1, if installed. Loosen the two clamp screws (with a #8 Phillips screwdriv er) on the rear of case and rotate the slide clamps. Push the two slide retainers to ward the rear of the unit and remov e them. 2. W orking from the front of the panel, inser t the meter into th ...

  • Omega DP3001 - page 11

    5 4.0 POWER AND SIGNAL A C versions of the v oltmeter are factory-set for 115 V ac in the USA and 230 V ac in Europe (using C1 option) ±15% operation. DC versions are preset f or 9-32 Vdc or 26-56 Vdc operation. It is not possible to change the meter from 9-32 Vdc to 26-56 Vdc or vice versa. Different static in verters are installed by the f actor ...

  • Omega DP3001 - page 12

    6 Figure 4.2 Rear T erminal Hookups Wire Color for A C P ower USA Other (High) Black Brown (Low) White Blue (Ground) Green Green Model P ower Signal AC D1 Connector A High 17 High 2 Low 16 L ow C Ear th Ground T Analog Ground D4 Connector 1 High 6 High 2 Low 5 L ow 3 Ear th Ground 4 Analog Ground DC D1 Connector 2 + DC 17 High C - DC (return) 16 L ...

  • Omega DP3001 - page 13

    7 4.3 MAIN BO ARD PIN ASSIGNMENTS (J1 Card Edge) Left to right, looking at rear of case P1 Connection Standard A Spare (E16) 1 No connection B No connection 2 Spare (E18) C Spare (E19) 3 No connection D No connection 4 No connection E Spare (E43) 5 No connection F 1999.9 (DP4) 6 Spare (E24) H 199.99 (DP3) 7 Spare (E23) J 19.999 (DP2) 8 Spare (E22) ...

  • Omega DP3001 - page 14

    8 4.4 SIGNAL INPUTS RA TIO : The reference input allo ws an external voltage to be used as the ref erence source for con version. In this mode, the meter reads the r atio of the signal voltage to the ref erence voltage rather than the true v alue of the input. Signal V oltage Reading in Counts = Ref erence V oltage x 10000 On the 20 V and 200 V ran ...

  • Omega DP3001 - page 15

    9 5.0 CO NFIGURA TION Select the desired configurations from the f ollowing char ts. Install jumpers and open/close solder s witches as indicated. Remov e all push-on jumpers not used. 5.1 DECIMAL POINT SELECTION Figure 5.1 Display Boar d Jumper Locations Decimal P oint S1 Alternate decimal point configuration using main board connector J1. 1.999 ...

  • Omega DP3001 - page 16

    10 5.2 V OL T A GE RANGE SELECTION Figure 5.2 Main Board J umper Locations *Ref er to Figure 5.3 . S3-A is used f or signal connections. Refer to Section 4 f or more information. Input Configuration Solder Switches* Push-on Jumpers Wire Jumper Open Close S2 S4 W10 2 Vdc J, L H, I, K - - Install 20 Vdc J, L H, I, K A B Remove 200 Vdc J, L H, I, K A ...

  • Omega DP3001 - page 17

    11 Figure 5.3 Solder Switch Locations Solder s witch F is used for ref erence input impedance ratio . Ref er to Section 4 for more inf or mation. 6.0 C ALIBRA TION This unit was f actor y-calibrated with a precision v oltage source. F requent calibration is not necessary due to the stability and inter nal accuracy . If calibration is needed, use th ...

  • Omega DP3001 - page 18

    12 7.0 DRA WINGS Figure 7.1 Assembly Dia gram, Main and Display Board ...

  • Omega DP3001 - page 19

    13 8.0 D UAL-SLOPE CONVERSION At the beginning of a conv ersion, the voltage across C int is z ero . The signal is then applied to the integrator and the v oltage across C int rises by the f or mula: T1 E Cint = Esig R int C int At the end of a fix ed per iod of 10000 counts, T1, the counters are reset to 00000. The signal input is turned off and ...

  • Omega DP3001 - page 20

    NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ____________________________ ...

  • Omega DP3001 - page 21

    15 NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ _________________________ ...

  • Omega DP3001 - page 22

    16 NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ _________________________ ...

  • Omega DP3001 - page 23

    WARRANTY / DISCLAIMER OMEGA EN GINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineer ing will extend the warranty period for one (1) additional year if the warranty card enclosed with each instru ...

  • Omega DP3001 - page 24

    M5280/1112 11119ML-99J Where D o I Find E verything I Need for Process M easurement and C ontrol? O ME GA… O f C ourse! Shop on line at omega.com T EM PE RATUR E R The rmocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies R Wire: Thermocouple, RTD & Thermistor R Calibrators & Ice Point References R Recorders, Control ...

Fabricant Omega Catégorie Crib Toy

Les documents que nous recevons du fabricant de l'appareilOmega DP3001 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega
- manuels d’utilisations DP3001
- fiches produit Omega
- dépliants
- ou étiquettes-énergie Omega DP3001
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega DP3001.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega DP3001, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega DP3001. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega DP3001.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Omega DP3001, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega DP3001 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega DP3001.

Le manuel d’utilisation complet Omega, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega DP3001 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega DP3001, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega DP3001 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega DP3001 - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega DP3001
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega DP3001
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega DP3001 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega DP3001?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega DP3001, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega DP3001 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)