Manuel d’utilisation Goodman Mfg SS-CPG36-72

40 pages 1.88 mb
Télécharger

Aller à la page of 40

Summary
  • Goodman Mfg SS-CPG36-72 - page 1

    SS-CPG36-72 www .goodmanmfg.com 6/11 Supersedes 4/11 Standard Featur es • R-410Achlorine-freer efrigerant • T uffTube™tubularheatexchanger • High-efciencyscrollcompressor • HIgh-andlow-pressur eswitches • Coppertube/aluminumncoils • Contactorwithlugs • Hig ...

  • Goodman Mfg SS-CPG36-72 - page 2

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 2 www .goodmanmfg.com SS-CPG36-72 n omenCla tUre  C P G 036 045 3 B X X X           Brand F actoryInstalledOp<ons      ? ...

  • Goodman Mfg SS-CPG36-72 - page 3

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 3 P rodUCt s PeCiFiCa tions — CPG0 36 B m odels CPG036 0451DXXX CPG036 0453DXXX CPG036 0453BXXX CPG036 0454BXXX   T ot al BTU/h 34,600 34,600 34,600 34,600 Sensible BTU/h 25,600 25,600 25,600 25,600 SEER / EER 13 / 1 ...

  • Goodman Mfg SS-CPG36-72 - page 4

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 4 www .goodmanmfg.com SS-CPG36-72 P rodUCt s PeCiFiCa tions — CPG0 36 B m odels ( Cont .) CPG036 0901DXXX CPG036 0903DXXX CPG036 0903BXXX CPG036 0904BXXX CPG036 0907BXXX   T ot al BTU/h 34,600 34,600 34,600 34,600 35,000 Sensible BTU/h 25,600 25,60 ...

  • Goodman Mfg SS-CPG36-72 - page 5

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 5 P rodUCt s PeCiFiCa tions — CPG048 B m odels CPG048 0901DXXX CPG048 0903DXXX CPG048 0903BXXX CPG048 0904BXXX   T ot al BTU/h 45,500 45,500 45,500 45,500 Sensible BTU/h 35,000 35,000 35,000 35,000 SEER / EER 13.0 / ...

  • Goodman Mfg SS-CPG36-72 - page 6

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 6 www .goodmanmfg.com SS-CPG36-72 P rodUCt s PeCiFiCa tions — CPG048 B m odels ( Cont .) CPG048 1151DXXX CPG048 1153DXXX CPG048 1153BXXX CPG048 1154BXXX CPG048 1157BXXX   T ot al BTU/h 45,500 45,500 45,500 45,500 45,500 Sensible BTU/h 35,000 35,000 ...

  • Goodman Mfg SS-CPG36-72 - page 7

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 7 P rodUCt s PeCiFiCa tions — CPG060 B m odels CPG060 0901DXXX CPG060 0903DXXX CPG060 0903BXXX CPG060 0904BXXX   T ot al BTU/h 59,500 59,500 59,500 59,500 Sensible BTU/h 43,200 43,200 43,200 43,200 SEER / EER 13 / 11 ...

  • Goodman Mfg SS-CPG36-72 - page 8

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 8 www .goodmanmfg.com SS-CPG36-72 P rodUCt s PeCiFiCa tions — CPG060 B m odels ( Cont .) CPG060 1401DXXX CPG060 1403DXXX CPG060 1403BXXX CPG060 1404BXXX CPG060 1407BXXX   T ot al BTU/h 59,500 59,500 59,500 59,500 59,500 Sensible BTU/h 43,200 43,200 ...

  • Goodman Mfg SS-CPG36-72 - page 9

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 9 P rodUCt s PeCiFiCa tions — CPG0 72 B m odels CPG072 1403BXXX CPG072 1404BXXX CPG072 1407BXXX   T ot al BTU/h 71,000 71,000 71,000 Sensible BTU/h 48,280 48,280 48,280 EER 11.1 11.1 11.1 Decibels 78.0 78.0 78.0 AHRI ...

  • Goodman Mfg SS-CPG36-72 - page 10

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 10 www .goodmanmfg.com SS-CPG36-72 a irFlo w d at a — CPG03 6B s tand ard d ireCt d rive — h orizontal s t andard d ireCt d rive — d own s ho t             ? ...

  • Goodman Mfg SS-CPG36-72 - page 11

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 11 a irFlo w d at a — CPG03 6B ( Cont .) s tand ard B elt d rive — h orizontal ESP  2    012345  BHP  BHP  BHP  BHP  BHP  BHP 0.2 1524 0.32 1340 0.25 0.4 1628 0 ...

  • Goodman Mfg SS-CPG36-72 - page 12

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 12 www .goodmanmfg.com SS-CPG36-72 a irFlo w d at a — CPG048B s tand ard d ireCt d rive — h orizontal s tand ard d ireCt d rive — d own s hot              ...

  • Goodman Mfg SS-CPG36-72 - page 13

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 13 a irFlo w d at a — CPG048B ( Cont .) s tand ard B elt d rive — h orizontal ESP  2    012345  BHP  BHP  BHP  BHP  BHP  BHP 0.2 1800 0.47 1556 0.35 0.4 2002 0. ...

  • Goodman Mfg SS-CPG36-72 - page 14

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 14 www .goodmanmfg.com SS-CPG36-72 a irFlo w d at a — CPG060B s tand ard d ireCt -d rive — h orizontal s t andard d ireCt -d rive — d own s ho t                 ? ...

  • Goodman Mfg SS-CPG36-72 - page 15

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 15 a irFlo w d at a — CPG060B ( Cont .) s tand ard B elt d rive — h orizontal ESP  2    012345  BHP  BHP  BHP  BHP  BHP  BHP 0.2 2460 0.96 2251 0.80 2073 0.65 1 ...

  • Goodman Mfg SS-CPG36-72 - page 16

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 16 www .goodmanmfg.com SS-CPG36-72 a irFlo w d at a — CPG07 2B s tand ard B elt d rive — h orizontal            ...

  • Goodman Mfg SS-CPG36-72 - page 17

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 17 e xP anded C oolinG d at a — CPG03 6B    65 75 85 95 105 115    ...

  • Goodman Mfg SS-CPG36-72 - page 18

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 18 www .goodmanmfg.com SS-CPG36-72 e xP anded C oolinG d at a — CPG03 6B ( Cont .)    65 75 85 95 105 115   ...

  • Goodman Mfg SS-CPG36-72 - page 19

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 19 e xP anded C oolinG d at a — CPG048B    65 75 85 95 105 115    ...

  • Goodman Mfg SS-CPG36-72 - page 20

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 20 www .goodmanmfg.com SS-CPG36-72 e xP anded C oolinG d at a — CPG048B ( Cont .)    65 75 85 95 105 115   ...

  • Goodman Mfg SS-CPG36-72 - page 21

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 21 e xP anded C oolinG d at a — CPG060B    65 75 85 95 105 115    ...

  • Goodman Mfg SS-CPG36-72 - page 22

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 22 www .goodmanmfg.com SS-CPG36-72 e xP anded C oolinG d at a — CPG060B ( Cont .)    65 75 85 95 105 115   ...

  • Goodman Mfg SS-CPG36-72 - page 23

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 23 e xP anded C oolinG d at a — CPG07 2B    65 75 85 95 105 115    ...

  • Goodman Mfg SS-CPG36-72 - page 24

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 24 www .goodmanmfg.com SS-CPG36-72 e xP anded C oolinG d at a — CPG07 2B ( Cont .)    65 75 85 95 105 115   ...

  • Goodman Mfg SS-CPG36-72 - page 25

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 25 d imensions 30 APPENDIX C UNIT DIMENSIONS Horizontasl Discharge Vertical Discharge NOTE For horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply openings. Install wi th insulation facing up, u ...

  • Goodman Mfg SS-CPG36-72 - page 26

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 26 www .goodmanmfg.com SS-CPG36-72 U nit C learanCes Maintainanadequateclearancear oundtheunitforsafety ,ser vice, maintenance,andproperunitopera tion.Leaveatotalclearanceof75”  onthemaincontrolpanelsideoftheu ...

  • Goodman Mfg SS-CPG36-72 - page 27

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 27 r ooF C UrB i nst allation — r iGGinG Provisionsforforkshavebeenincludedin theunitbase frame.Noother for k locationsar eapproved. • Unitmustbeliftedbythefourliftingholesloca teda ...

  • Goodman Mfg SS-CPG36-72 - page 28

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 28 www .goodmanmfg.com SS-CPG36-72 r ooF C UrB i nst allation ( Cont .) Curb installations must comply with local codes and should follow the established guidelines of  the National Roong Contractors  Association. Proper unit installat ...

  • Goodman Mfg SS-CPG36-72 - page 29

    P roduct S Pecifica tionS P roduct S Pecifica tionS SS-CPG36-72 www .goodmanmfg.com 29 W iring d iagram — cPg0 36045 1d (S ingle -P haSe , d irect d rive ) 2. FOR 208 VOLT TRANSFORME R OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFOR MER. 1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS O RIGINAL. (USE COPPER ...

  • Goodman Mfg SS-CPG36-72 - page 30

    P roduct S Pecifica tionS P roduct S Pecifica tionS 30 www .goodmanmfg.com SS-CPG36-72 W iring d iagram — cPg0 36/ 480901d (S ingle -P haSe d irect d rive ) 2. FOR 208 VOLT TRANSFORME R OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFOR MER. 1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS O RIGINAL. (USE COPPE ...

  • Goodman Mfg SS-CPG36-72 - page 31

    P roduct S Pecifica tionS P roduct S Pecifica tionS SS-CPG36-72 www .goodmanmfg.com 31 W iring d iagram — cPg060*1d (S ingle -P haSe d irect d rive ) AUXILLARY LIMIT SWITCH FEMALE PLUG/ CONNECTOR INTEGRATED IGNI TION CONTROL VMR LS 4 INSTALLER/SERVICEMAN TROUBLESHO OTING THIS APPLIAN CE. STATUS LIGH T CODES ARE AS FOLLOWS: THE STATUS LIGHT ON THE ...

  • Goodman Mfg SS-CPG36-72 - page 32

    P roduct S Pecifica tionS P roduct S Pecifica tionS 32 www .goodmanmfg.com SS-CPG36-72 W iring d iagram — cPg060*3d (t hree -P haSe , d irect d rive ) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ W arning High Voltage: Disconnect all power bef ore ser vicing or installing this uni ...

  • Goodman Mfg SS-CPG36-72 - page 33

    P roduct S Pecifica tionS P roduct S Pecifica tionS SS-CPG36-72 www .goodmanmfg.com 33 W iring d iagram — cPg0 36.48*3d (t hree -P haSe d irect d rive ) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ W arning High Voltage: Disconnect all power bef ore ser vicing or installing this u ...

  • Goodman Mfg SS-CPG36-72 - page 34

    P roduct S Pecifica tionS P roduct S Pecifica tionS 34 www .goodmanmfg.com SS-CPG36-72 W iring d iagram — cPg0 36/ 48*3d (t hree -P haSe , d irect d rive ) Wiring is subject to change. Alwa ys ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W arning High V oltage: Disconnect all power befor e servicing or installing ...

  • Goodman Mfg SS-CPG36-72 - page 35

    P roduct S Pecifica tionS P roduct S Pecifica tionS SS-CPG36-72 www .goodmanmfg.com 35 W iring d iagram — cPg0 36-600904B/7B — cPg0 36*4B/7B — cPg0 72*4B/7B (460v/57 5 v , B elt d rive ) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ W arning High Voltage: Disconnect all power b ...

  • Goodman Mfg SS-CPG36-72 - page 36

    P roduct S Pecifica tionS P roduct S Pecifica tionS 36 www .goodmanmfg.com SS-CPG36-72 W iring d iagram — cPg0 36/ 48/ 60090 3B — cPg07 2*3B (t hree -P haSe , B elt d rive ) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ W arning High Voltage: Disconnect all power bef ore ser vici ...

  • Goodman Mfg SS-CPG36-72 - page 37

    P roduct S Pecifica tionS P roduct S Pecifica tionS SS-CPG36-72 www .goodmanmfg.com 37 W iring d iagram — cPg0 36/ 480454B — cPg07 2*4B/7B (460v/ 575v B el t d rive ) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ W arning High Voltage: Disconnect all power bef ore ser vicing or i ...

  • Goodman Mfg SS-CPG36-72 - page 38

    P roduct S Pecifica tionS P roduct S Pecifica tionS 38 www .goodmanmfg.com SS-CPG36-72 W iring d iagram — cPg0 36/ 480453B (t hree -P haSe , B el t d rive ) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ W arning High Voltage: Disconnect all power bef ore ser vicing or installing th ...

  • Goodman Mfg SS-CPG36-72 - page 39

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions SS-CPG36-72 www .goodmanmfg.com 39 a CCessories      14CURB3672B Roof Curb – 14" T all 3-6 tons 25FD3672 25% Manual Fresh Air Damper 3-6 tons 25MFD3672 25% Motoriz ed Fresh Air Damper 3-6 tons ...

  • Goodman Mfg SS-CPG36-72 - page 40

    P rodUCt s PeCiFiCa tions P rodUCt s PeCiFiCa tions 40 www .goodmanmfg.com SS-CPG36-72 GoodmanManufacturingCompany ,L.P .,reservestherighttodiscontinue,orchangeatanytime,specicationsordesignswithout noticeorwithoutincurringobligations.©2011•GoodmanManufa ...

Fabricant Goodman Mfg Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilGoodman Mfg SS-CPG36-72 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Goodman Mfg
- manuels d’utilisations SS-CPG36-72
- fiches produit Goodman Mfg
- dépliants
- ou étiquettes-énergie Goodman Mfg SS-CPG36-72
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Goodman Mfg SS-CPG36-72.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Goodman Mfg SS-CPG36-72, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Goodman Mfg SS-CPG36-72. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Goodman Mfg SS-CPG36-72.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Goodman Mfg SS-CPG36-72, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Goodman Mfg SS-CPG36-72 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Goodman Mfg SS-CPG36-72.

Le manuel d’utilisation complet Goodman Mfg, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Goodman Mfg SS-CPG36-72 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Goodman Mfg SS-CPG36-72, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGoodman Mfg SS-CPG36-72 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Goodman Mfg SS-CPG36-72 - qui devraient nous aider dans les premières étapes lors de l'utilisation Goodman Mfg SS-CPG36-72
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Goodman Mfg SS-CPG36-72
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Goodman Mfg SS-CPG36-72 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Goodman Mfg SS-CPG36-72?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Goodman Mfg SS-CPG36-72, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Goodman Mfg SS-CPG36-72 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)