Honeywell L8104B - page 1
1 68-0063—3 J. H. • Rev. 6-95 • ©Honeywell Inc. 1995 L8104A,B,C,D Electr onic W ater Heater Contr ollers The L8104A,B,C,D Electronic Controllers pro- vide temperature control and ECO limit action for gas water heaters. L8104B with Potentiometer Remote Potentiometer Sensing Bulb ■ L8104A,B are used in standing pilot and electronic ignition ...
-
Honeywell L8104B - page 2
68-0063—3 2 L8104A,B,C,D SPECIFICATIONS • ORDERING INFORMATION Specif ications IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and cali- brated under closely controlled conditions, and some m ...
-
Honeywell L8104B - page 3
3 68-0063—3 L8104A,B,C,D SPECIFICATIONS DIMENSIONS: L8104: Fig. 1. L8104A,B: Fig. 2. L8104C,D: Fig. 3. APPROVALS: Underwriters Laboratories Inc. Component Recognized: File No. MP466, Guide No. MBPR2. American Gas Association Certified: Report No. 70-22A. Canadian Gas Association Certified: Report No. 1029- CC/T-6849. OTHER SYSTEM COMPONENTS (Orde ...
-
Honeywell L8104B - page 4
68-0063—3 4 L8104A,B,C,D SPECIFICATIONS ACCESSORIES: L8104A: 4074ENP Potentiometer Assembly: 199075A Poten- tiometer: Clockwise turn increases temperature, two 18 in. [46 cm] leadwires with 1/4 in. quick connects. Washer and nut. 4074ENS Potentiometer Assembly: 199053A Potenti- ometer: Counterclockwise turn increases tempera- ture, two 18 in. (46 ...
-
Honeywell L8104B - page 5
5 68-0063—3 L8104A,B,C,D INSTALLATION Installation WHEN INSTALLING THIS PRODUCT… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a ...
-
Honeywell L8104B - page 6
68-0063—3 6 L8104A,B,C,D INSTALLATION Fig. 5—L8104A with board-mounted potentiometer in a standing pilot application. M131C POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1/4 IN. TAB TERMINALS (3). 3/16 IN. TAB TERMINALS (3). SENSING BULB WITH ECO SWITCH 1 2 2 2 3 3 3 L1 (HOT) L2 1 2 3 1 4 0 120 160 180 100 L8104A B ...
-
Honeywell L8104B - page 7
7 68-0063—3 L8104A,B,C,D INSTALLATION Fig. 7—L8104B with remote potentiometer in a standing pilot application. Fig. 8—L8104B with board-mounted potentiometer in an electronic ignition application. M130C POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY JUMPER INSTALLED, DO NOT REMOVE. 1/4 IN. TAB TERMINALS (3 ...
-
Honeywell L8104B - page 8
68-0063—3 8 L8104A,B,C,D INSTALLATION Fig. 9—L8104C with remote-mounted potentiometer in an electronic ignition application. SENSING BULB WITH ECO SWITCH 1 2 3 SETPOINT POTENTIOMETER (SHOWN FROM BACK) L1 (HOT) L2 1 4 3 1 2 4 5 3 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. DO NOT REMOVE. ...
-
Honeywell L8104B - page 9
9 68-0063—3 L8104A,B,C,D INSTALLATION Fig. 10—L8104D with remote-mounted potentiometer in an electronic ignition application SENSING BULB WITH ECO SWITCH 1 2 3 SETPOINT POTENTIOMETER (SHOWN FROM BACK) L1 (HOT) L2 1 4 3 1 2 4 5 3 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. DO NOT REMOVE. ...
-
Honeywell L8104B - page 10
68-0063—3 10 L8104A,B,C,D SETTING AND CHECKOUT Setting and Check out SET CONTROL TEMPERATURE If the potentiometer is mounted on the control module, turn the selector knob to the desired temperature. If the potentiometer is remotely mounted, the position of the flat part of the shaft determines the approximate control temperature. Fully counterclo ...
-
Honeywell L8104B - page 11
11 68-0063—3 L8104A,B,C,D SETTING AND CHECKOUT • OPERATION TABLE 2—THERMISTOR RESISTANCE AT VARIOUS TEMPERATURES IN CELSIUS. Operation L8104A,D When the temperature at the sensing bulb drops below the setting on the potentiometer, the relay contacts in the electronic control module make to open the gas control or turn on the ignition module. ...
-
Honeywell L8104B - page 12
68-0063—3 12 L8104A,B,C,D TROUBLESHOOTING DISCONNECT SENSOR LEADS FROM ELECTRONIC CONTROL MODULE AND MEASURE RESISTANCE OF SENSOR(S) WITH OHMMETER. IS RESISTANCE BETWEEN 700K AND 30K OHMS (SEE TABLE 1)? SENSOR(S) OK. DISCONNECT ECO LEADS AND MEASURE RESISTANCE WITH OHMMETER. IS WATER TEMPERATURE GREATER THAN 210˚F AND ECO RESISTANCE LESS THAN 10 ...
-
Honeywell L8104B - page 13
13 68-0063—3 L8104A,B,C,D TROUBLESHOOTING CHECK TRANSFORMER, 120V SUPPLY, CORRECT AS NECESSARY. IGNITION MODULE WAS IN LOCKOUT. OBSERVE FOR 2-3 CYCLES TO MAKE SURE SYSTEM IS OTHERWISE OK. SENSOR(S) MAY BE SHORTED OR OPEN. CHECK FOR LOOSE, BROKEN OR SHORTED WIRES. REPLACE SENSING BULB(S) IF NECESSARY. REPLACE ELECTRONIC CONTROL MODULE. RECONNECT A ...
-
Honeywell L8104B - page 14
68-0063—3 14 L8104A,B,C,D TROUBLESHOOTING CHECK TRANSFORMER, 120V SUPPLY, CORRECT AS NECESSARY. IGNITION MODULE WAS IN LOCKOUT. OBSERVE FOR 2-3 CYCLES TO MAKE SURE SYSTEM IS OTHERWISE OK. NO YES CHECK VOLTAGE AT 24V TERMINALS OF ELECTRONIC CONTROL MODULE. IS THIS AN ELECTRONIC IGNITION SYSTEM WITH 100 PERCENT LOCKOUT? DISCONNECT 24V POWER AT IGNI ...
-
Honeywell L8104B - page 15
15 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...
-
Honeywell L8104B - page 16
68-0063—3 16 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...
-
Honeywell L8104B - page 17
17 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...
-
Honeywell L8104B - page 18
68-0063—3 18 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...
-
Honeywell L8104B - page 19
19 68-0063—3 L8104A,B,C,D MATERIAL SAFETY DATA SHEET ...
-
Honeywell L8104B - page 20
68-0063—3 20 L8104A,B,C,D MATERIAL SAFETY DATA SHEET Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario M1P 2V9 Printed in U.S.A. customer.honeywell.com ...